Pre-resolution status
1. Interface Configuration
Interface TENGIGABITETHERNET3/1
Description to c4507-387-standby-10g
Switchport mode Trunk
Channel-group-mode on
End
2. Interface status
Sw-sjhl-2c-386-core#show Interfaces Tengigabitethernet 3/1
TENGIGABITETHERNET3/1 is off, line protocol was down (inactive)
Hardware is Ten Gigabit Ethernet Port, Address is 1cdf.0f51.8140 (BIA 1cdf.0f51.8140)
Description:to c4507-387-standby-10g
MTU bytes, BW 10000000 Kbit, DLY usec,
Reliability 255/255, Txload 1/255, Rxload 1/255
Encapsulation ARPA, loopback not set
Keepalive Set (SEC)
Full-duplex, 10gb/s, link type is auto, media type is No X2
Input Flow-control is off, output Flow-control is off
ARP Type:arpa, ARP Timeout 04:00:00
Last input never, output never, output hang never
Last clearing of "show interface" counters never
Input queue:0/2000/0/0 (size/max/drops/flushes); Total Output drops:0
Queueing Strategy:fifo
Output Queue:0/40 (Size/max)
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
0 packets Input, 0 bytes, 0 no buffer
Received 0 broadcasts (0 multicasts)
0 runts, 0 giants, 0 throttles
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored
0 input packets with dribble condition detected
0 packets output, 0 bytes, 0 underruns
0 output errors, 0 collisions, 3 interface resets
0 babbles, 0 late collision, 0 deferred
0 lost carrier, 0 no carrier
0 output buffer failures, 0 output buffers swapped out
sw-sjhl-2c-386-core#
3, error log logs
Jan 02:16:15:%c4k_glmman-3-twingigconverteridentfailed:port TE3/1: Failed to identify TwinGig Converter
Solutions
1. Type mode of the conversion interface
Hw-module Module 3 port-group 1 Select tengigabitethernet
Hw-module Module 3 port-group 2 Select Tengigabitethernet
2. Check the interface type again
Sw-sjhl-2c-386-core#show Interfaces Tengigabitethernet 3/1
TENGIGABITETHERNET3/1 is off, line protocol was down (Notconnect)
Hardware is Ten Gigabit Ethernet Port, Address is 1cdf.0f51.8140 (BIA 1cdf.0f51.8140)
Description:to c4507-387-standby-10g
MTU bytes, BW 10000000 Kbit, DLY usec,
Reliability 255/255, Txload 1/255, Rxload 1/255
Encapsulation ARPA, loopback not set
Keepalive Set (SEC)
Full-duplex, 10gb/s, link type is auto, media type is No X2
Input Flow-control is off, output Flow-control is off
ARP Type:arpa, ARP Timeout 04:00:00
Last input never, output never, output hang never
Last clearing of "show interface" counters never
Input queue:0/2000/0/0 (size/max/drops/flushes); Total Output drops:0
Queueing Strategy:fifo
Output Queue:0/40 (Size/max)
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
0 packets Input, 0 bytes, 0 no buffer
Received 0 broadcasts (0 multicasts)
0 runts, 0 giants, 0 throttles
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored
0 input packets with dribble condition detected
0 packets output, 0 bytes, 0 underruns
0 output errors, 0 collisions, 3 interface resets
0 babbles, 0 late collision, 0 deferred
0 lost carrier, 0 no carrier
0 output buffer failures, 0 output buffers swapped out
sw-sjhl-2c-386-core#
This article is from the "zhanguo1110" blog, make sure to keep this source http://zhanguo1110.blog.51cto.com/5750817/1606878
Using the Gigabit module on the Cisco 4507 switch engine