Take Dell poweredage 6450 as an example:
Two 6450 servers and one Dell powervanlt 201s disk array cabinet.
Two servers: one 9 gb scsi hard disk, one Dell Perc 2/DC card, the hard disk connected to the SCSI card, one integrated

Intel 8255x-based PCI Ethernet network card, an Intel PRO 100 + network card.
Disk Array configuration: 6 16 gb scsi hard disks
Two Dell heartbeat Network cables
One Hub
1. Configure the server
1. connect two servers A and B. Two intel 8255x-based PCI Ethernet hard jumper links, two Intel PRO

100 + connect to the hub with two network cables.
2. Open both servers and install Windows 2000 Advanced Server on both servers A and B.
3. configure Server A as a domain controller. If the domain name is server. com ).
4. Configure the IP addresses of the two NICs. For example, Intel 8255x-based PCI Ethernet is set to 10.1.1.10 Intel PRO 100 +

111.111.111.10
5. Add Server B to the domain of server a in two ways:
A. When installing Windows 2000, the computer will prompt whether to join an existing domain, select add, and enter

Domain, select Custom installation, set the IP address intel 8255x-based PCI Ethernet to 10.1.1.20, and Intel PRO 100 +

111.111.111.20. Then, the server will not prompt that it has been added to the domain and it will continue to install. This is different from NT 4.0.

.
Note: Make sure that the two servers are connected and the protocols must be configured.
B. if you choose not to add an existing domain during installation, You can manually add it after entering Windows 2000. Details

Method: Right-click my computer, click Properties, select a network ID, click Properties, enter the domain to be added, and follow the wizard.
6. Note: The two NICs of the two servers must be configured in the same domain.
7. Restart server a and server B, and press Ctrl + m to enter Dell prec 2/DC and configure prec card
A. Set the cluster mode to enable. The method is objects---adapter --- clustremode.
B. Set the BIOS of Perc 2/DC to disable (select enable)
C. Set the initiator ID of the perc 2/DC card to 6 for server a and 7 for server B.
D. Exit the prec card settings and disable server a and server B.
Ii. Configure the powervanlt 201s disk array
1. pv201s has two Es em s cards, which are pulled out. Each of them has a patch cord jp8, which is used to transient jp8.
2. Connect pv201s with server a's prec 2/DC on the SCSI line. Enter the BIOS configuration disk array (pv201s) of prec 2/DC

RAID (usually RAID 5), and then select initialize settings.
3. Exit.
Note: Server B is disabled at this time.
3. Configure clustre
1. Disable server B.
2. Open Server A, go to Windows 2000, and upgrade Windows 2000 Perc 2/DC driver as follows:
The Perc driver must be upgraded on two nodes. The following process describes the process of updating the driver:
# Update the perc driver
1. Choose Start> program> Management Tools> Computer Management.
2. Under [System Tools], select [device management].
3. Click SCSI and RAID Controller on the right panel.
4. Right-click AMI meagraid or Dell Perc 2/dc raid Controller and select [properties].
5. Click the [Driver] page and then click [update driver].
6. On the update driver wizard page, click [next].
7. In the list, select [display the list of drivers for known devices, select a specific driver], and then click [next].
8. Click [install from disk].
9. Insert a floppy disk containing a new driver to the floppy disk drive and click [OK].
10. Select Dell on the left panel, and then select the perc 2/dc raid Controller on the right panel.
11. Click [next].
12. If you have a driver warning form, click [Yes].
13. Click [next].
14. After the driver installation is complete, click [finish].
15. Select [Restart computer] and click [Yes] to restart the computer.
3. After Entering Windows 2000, configure the cluster as follows:
1. Choose Start> program> Management Tools> Computer Management.
2. Click [disk management] to view the current disk in the right pane.
3. The signature and disk Upgrade Wizard is automatically displayed. Otherwise, right-click the gray [disk 0] and click [Signature].
4. Click [next].
5. Select all disks and click [next].
6. If the disk does not need to be upgraded, deselect all selected disks and click [next].
7. Click [finish].
8. The read/write status of the disk must be basic. If they are dynamic, right-click each disk and select [restore to basic magnetic

Disk].
9. Right-click the first disk (Disk 0) and select [create disk].
10. Click [next].
11. Check whether the [primary partition] is selected, and then click [next].
12. Check whether the maximum disk space is available and click [next].
13. Assign the drive letter of the first disk to Z and click [next].
14. Check whether the NTFS file system is selected and click [next].
15. Click [finish].
16. After the first disk format is complete, repeat steps 8-15 to create a shared drive for each disk and select the last available drive letter

.
17. Disable server.
Note: It is recommended that the given drive letter start from the Z disk and set the status of the recognized Z disk from dynamic to the basic status so that the following

Cluster services can be installed. The modification method is as follows: Right-click my computer, select Manage, select disk management, right-click disk 0, and select set as base

This status.
4. Disable server a, enable server B, configure cluster on server B, and disable server a during this process. The configuration process is as follows:

Below:
Note: Because server a has RAID 5 for pv201s and formatted the hard disk, you do not need to redo RAID 5 on server B.

Save it.
# Change drive name and path of server B
1. Restart server B and log on as the system administrator.
2. Choose Start> program> Management Tools> Computer Management, and then select [disk management].
3. Right-click [disk 0] and choose [Change drive name and path].
4. Click [edit].
5. When assigning a drive letter, change the current drive letter to select drive letter Z, and then click [OK].
6. Click [Yes] to confirm and change the drive letter.
7. Repeat steps 3-7 to change the remaining shared disk.
5. You must configure cluster services for both cluster nodes. This is done through the window popped up when the system reboot is completed after each setup. This

This step can be completed when both nodes are started. Start with node.
The configuration steps for server a are as follows:
# Configure cluster nodes on server
1. After the system is started, the installation completion dialog box is displayed automatically. Click [installation completed]. If the installation screen is turned off,

Click Start> program> Management Tools> Configure server and click [install complete].
2. Click [configuration] under the installation service.
3. Click [next].
4. Click "I understand" and then [next].
5. Select "first node" when installing node ".
6. Enter a name for the cluster. Click [next].
7. Enter a name and password for the domain account. This account should be the same as the node Accounts added to this domain. (Recommended)

Administrator), click [next].
8. Shared disks are automatically displayed in the disk management window. Click [next].
9. Cluster files should be stored in shared disks. Select disk Z. Click [next].
10. Click [next].
11. Configure the first Nic as a public network and select "client access only" (Public Network ). Click [next].
12. Select Intranet cluster connection as the second Nic. (Private Network) Click [next].
13. Click [OK].
14. Enter an expected public IP address for the cluster IP address. The subnet mask is 255.255.255.0.
15. Click [finish].
The configuration steps of server B are as follows :.
# Configure cluster nodes in server B
1. After the system is started, the installation completion dialog box is displayed automatically. Click [installation completed]. If the installation screen is turned off,

Click Start> program> Management Tools> Configure server and click [install complete].
2. Click [configuration] under the installation service.
3. Click [next].
4. Click "I understand" and then [next].
5. Select "second or next node" when installing Node B, and then click [next].
6. The cluster names of node A and Node B should be consistent. Select or enter the cluster name of node A and click [next].
7. Click [OK].
8. Enter a name and password for the domain account. This account should be the same as the node Accounts added to this domain. (Recommended)

Administrator), click [next].
9. Click [finish].

6. Check the Cluster
# Check the Cluster
1. Choose Start> program> management tools and click cluster management. (In server B)
2. nodes A and B should display a "up." status.
3. Minimize cluster management and move to server.
4. Select Start Menu> program> attachment> Windows resource manager. Z disk is available. Click Z disk to view Z disk of node.

Contains the quolog file, which is not a text file. Do not open or modify it.
5. Move to Node B and choose "start"> "program"> "attachment"> "Windows Resource Manager". The Z disk cannot be seen in Node B.
6. Turn off a and use Windows Explorer to find the Z drive on B 30 seconds later. If node A fails, switch to Node B.

Related Article

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.