Support Education Informatization APC build integrated Core Room

Source: Internet
Author: User
Keywords Server solution data center Schneider data center

BEIJING/China, February 13, 2012--the global leader in key power and refrigeration services Schneider Electric's APC (APC) recently announced that the integrated solution provided by APC successfully settled in the core data room of Northwestern University's Changan campus, providing the data center with key power supply, Integrated physical infrastructure solutions for refrigeration and http://www.aliyun.com/zixun/aggregation/23104.html "> Monitoring Systems". The integration of the programme, its high reliability and availability, and the need to comprehensively build high-quality green data centers while balancing overall costs. After the completion of the data center room, its outstanding integration advantages and advanced computer room overall construction perspective, for those who seek high-performance solutions for similar users to provide a model for reference.

"Informatization of education industry not only carries the needs of the users of the education industry, but also carries the deep demand for the efficient use of educational resources by the whole social progress," said Huang Honghong, senior vice president of APC and Greater China. Because of this, its overall demand for information has been maintained at a high level. Specific to the education industry users in the construction of data center, the user advanced, performance and easy to manage the maintenance of the solution has a clearer demand. APC has extensive practical experience and innovative solutions in the Data center field, and always in the market to maintain a strong advantage, can provide users, including data center for distribution, refrigeration, security, monitoring and other integrated solutions and services, fully meet the hope of building an integrated, highly integrated data center users needs. ”

Northwest University of Chang ' an campus is located in Xi ' an city Changan District, the new core computer room project is located in the Northwest University of Changan campus graphic information building, building area of about 519 square meters. The core computer room is the center of Northwest University Campus Network, which undertakes the interconnection and interworking with Taibai Campus and Taoyuan Campus, and provides operation guarantee for the core data and key applications of campus network. In order to ensure the normal operation of all the equipment in the core room, it is necessary to use efficient and safe technology and equipment to provide uninterrupted operation and safe and reliable working environment for the equipments in the core room. Therefore, the Changan campus of Northwestern University has put forward the clear demand for the integration, high availability, high reliability and high expansion of the new core room. At the same time, from the total cost of ownership, the construction party requires a comprehensive planning of the data center distribution, refrigeration, security, access control and later operation management and other aspects, hope to effectively optimize the overall structure of the data center to control the power consumption, so that the real data center from the upfront capital expenditure to the late operating costs of the return on investment.

Taking into account the APC's technical advantages in the data center market and world-class building experience, the core computer room project of the Northwest University's Changan campus has finally chosen the overall solution provided by APC. In view of the importance of the initial environment and load of the data center, the need to provide power redundancy protection to the important load, the data center deployed 2 sets of Galaxy5000 120KVA three-phase UPS system. Galaxy 5000 integrates efficient performance into the entire precision structure, enabling all components to be operated from the front to facilitate maintenance. The modular design of Galaxy 5000 means that the core room will become a standardized process, and, if necessary, can connect up to 6 redundant UPS units to accommodate the uncertainties in the installation to achieve high availability.

In addition, the refrigeration of the data center is also a very concerned part of the user, in addition to the requirements of the computer room air-conditioning system with air supply, return air, heating, humidification, cooling, moisture and air purification functions, in order to ensure the efficiency of equipment and energy-saving, but also require unit refrigeration system with the environment and load requirements, accurate adjustment of refrigeration capacity. APC for the user needs and room environment, provided 3 Schneider Electric air-conditioning TDAR1622, the program is not only a stand-alone system with redundant configuration, and at the refrigeration system level to ensure redundancy; At the same time, the precision air-conditioning system also integrates the Schneider Electric air-conditioning unique intelligent control system, Therefore, the user can easily adjust to meet the different operating parameters, performance indicators and thermal load distribution requirements. These focus on the user's actual needs of products and technology, together to form an APC for Northwestern University to provide an integrated solution, and this program for the Northwest University Building information platform for the campus, and even the future development of the school provides a strong support.

(Author: anon Editor: Meng)
Related Article

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.