Welcome to pay attention to http://www.raymontec.com (Personal special blog) Altium Designer Learning-understanding interface and overall PCB design requirementshttp://www.raymontec.com/altium-designer-%e5%ad%a6%e4%b9%a0-%e8%ae%a4%e8%af%86%e7%95%8c%e9%9d%a2%e4%bb%a5%e5% 8f%8apcb%e8%ae%be%e8%ae%a1%e6%95%b4%e4%bd%93%e
after seeing andy_2020 's post "Altium designer Theme", I was interested in the 3D features of Altium Designer and started to make an ad 3D package library. Just started in the way Andy introduced, learned two days SolidWorks, drew a PQ3230 transformer. I paint the transformer, the big god do not spraybut later found
Take Altium Designer 6.9 for example:1. Click Dxp→run Script.2. Click Browse to open: ad's installation directory under \altium Designer 6\examples\scripts\delphiscript scripts\pcb\pcb Logo Creator\ PCBLOGOCREATOR.PRJSCR file3. Select Runconverterscript, then click OK.4. load the BMP file and select which layer you wan
Altium Designer v15.1.12 win7_8 1DVD Integrated Electronic Product development systemAltium Vault 2.5.9.45043 1CD Unified Library and Multiplexing module managementAltium Designer is the original Protel software developer Altium Company launched an integrated electronic product development system, mainly run on the Win
In the PCB board production finished, in order to demonstrate their sense of accomplishment, you can add a few logo or explanatory English in the blank area of the PCB (do not Chinese, Chinese may not do PCB manufacturers).I like to add a personalized two-dimensional code in the blank area, counted as a small affirmation of their achievements. Sweep a prize ha!! (joking drops).Before the logo design, you need to download the logo generation plugin, can be downloaded in the Baidu network disk. Ht
Altium designer BGA fan out 2012-02-28 14:52:06 share:First, Altium Designer has known for so long, did not use his automatic fan-out function, today, a try, the effect is good, but now has not found not fan out no network pin method, I now talk about my automatic fan out step to everyone to say, in the BGA above the r
Turn chenzelin2009 csdn Blog: http://blog.csdn.net/chenzelin2009/article/details/5751251#Altium Designer's multi-drawing function feels more convenient; today, I turned down teacher Xu "Altium designer Quick Start" in the introduction of multi-drawing design, and then refer to the Altium website some information, is fa
Reprint Please specify: http://blog.csdn.net/u011046042/article/details/73824333
The use of Altium Designer drawing schematic diagram is found to find no signal generator, is generally labeled as XFG1 is a function generator, XFC1 oscilloscope.
Found in Altium Desinger for a long while did not find finally find in the view to open the related toolbar
As shown
The actual results of the PCB effect (note slot edge) in the different layers of the hole shape are drawn in different layers of the slot shape (note the slot edge)Many friends asked in the use of Altium designer PCB design, want to open a slot on the board or dig a hole how to operate, is the use of keep-out layer or mechanical layer, today, here to answer, both in the actual operation are used (and large
For an example of a eight-pin AD8009-phase amplifier, review the process of the Altium designer artboard with the following steps:1, new project, and new Sch file and add the project. Schematic diagram of the board (Sch):A, most of the schematic devices can be found in their own library, commonly used are device and connector. If not, there are a lot of ready-made components in the forum, Sch, you can click
Tags: establish the company convenient data info version control database PCBObjectiveUsing the Altium Designer database feature, you can easily link components with the company's schematic library, PCB library, and device parameters to reduce human error, and improve output BOM, statistical price efficiency.Preparation materials
Schematic Library
PBC Library
1. Create ExcelOperation Steps
fixed column hole size should be more than 5.2mm (generally for the sake of easy to use the hole directly instead of 5.2mm 7mm)If it is the top layer of the double layer and the bottom of the line is best perpendicular to each other (parallel will cause a capacitance between the presence of the two)Crystal oscillator should be close to the chip so as to play a certain role (sometimes the crystal next to a large resistance effect is stable)Each power pin of the chip should be connected to a 0.01
This error pops up at the time of copying the schematic diagram.Invalidparameter at 2510219C.AdvSch.dll, Base address:24c80000.Exception occurred in CopyMethod 1:Let's see if we can join the local printer. If you can't join the printer, check my computer on the desktop. right mouse button Select "Manage";In the manage form, choose the Services option under the Services and Applications extension project, locate the print Spooler service in the list of system services that appears on the right si
Online about batch modification also has a lot of introduction, in accordance with the attempt of the Internet in the modification of the PCB can be normal operation,But in the schematic, but can only modify one, the reason, the original is a bad step. The correct steps are:1. Select one of the devices to be modified first.2, right-click Find similar objects, and then in the Pop-up dialog box, the property you want to modify is changed to same3, click on the application, the schematic diagram of
made of PCB board part is on the silver-white solder, not on the green oil this is not strange; but we draw the PCB board on the line part, only the toplayer or Bottomlayer layer, There is no solder layer, but the PCB board is made of traces on the part of a layer of green oil.That can be understood as follows: 1, solder resistance layer means that the whole piece of green Oil resistance welding window, the purpose is to allow welding! 2, by default, there is no solder layer of the area should
This program cannot be started because MFC71.DLL is missing from the computer. Try reloading the programBaidu under Search download MFC71.DLL, after decompression copy to c:windows/system32/, under Start-run input regsvr32 MFC71. DLL Carriage returnHttp://www.xiazaiba.com/html/6125.htmlAltium Designer 10 installation files. txtUse Thunder to open the following address : ed2k://|file| altiumdesignerrelease10.0.0.20340-beta.zip|1795619101| f6aa43869747
1. Version: Altium Designer 102, Reason: In the multi-schematic design, the different schematic diagram through the net label connection, and the ad default Net label (network label) scope is automatic, that is, when Sch has sheet Entry (sheet entry) or port (port), the net The label is scoped to a single sheet. In the design, the scope of the net label is modified because the port exists, but the net label
Altium Designer uses the wizard to paint the package library
The methods have been summed up very well by the predecessors. Cite the results of the predecessors, in case the time is long forgotten. First of all, I would appreciate the work of our predecessors.For example, Altium designer6.9 draws a BTS7960 package.Firs
1, keyboard shortcut combination o+g, open the grid Manager, click "Menu" in the lower left corner, in the dialog box, select "Add Polar Grid".2. Double-click the newly added raster with priority Level 1 and set the contents in the Polar Grid Editor dialog box that pops up.Please check out my example diagram and try more. When choosing a placement, click "Set the origin in PCB view" in the lower left corner and click "Apply" without setting an item. You can see the changes in the contents of the
) MOSFETN (n-channel reinforced tube) MOSFETP (P-Channel reinforced tube)The PIN package is in the same form as the transistor.6, inductance: inductor, INDUCTOR1, INDUCTOR2 (ordinary inductor), inductor VAR, INDUCTOR3, INDUCTOR4 (variable inductance)8. The BRIDGE1 and BRIDGE2 are often used in the bridge schematic diagram, and the PIN package is in the D-series, such as d-44,d-37,d-46.9. Single-row multi-pin sockets the often used name in the schematic is the Con series. From CON1 to CON60, the
The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion;
products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the
content of the page makes you feel confusing, please write us an email, we will handle the problem
within 5 days after receiving your email.
If you find any instances of plagiarism from the community, please send an email to:
info-contact@alibabacloud.com
and provide relevant evidence. A staff member will contact you within 5 working days.