bmc itsm

Alibabacloud.com offers a wide variety of articles about bmc itsm, easily find your bmc itsm information here online.

MySQL local database How to guide data from a remote database _mysql

Written in the front: recently started with the Ubuntu system, there is no good MySQL interface program, so .... Can only use the terminal operation of the. Operation Process: Open "terminal", directly enter the following content, click to return That's a word, oh! Purpose: Copy the database of the remote server to the local. Java code Copy Code code as follows: Mysqldump-h ' 114.212.111.123 '-urose-pxxxooo--opt--compress ITSM--skip-lo

Introduction to L2 Switch Security

network equipment manufacturers, switches that enhance security are upgraded and improved for general switches. In addition to general functions, such switches also have security policy functions that are not available for general switches. Based on network security and user business applications, this type of switch can implement specific security policies, restrict unauthorized access, and conduct post-event analysis to effectively ensure the normal development of users' network services. One

Brief discussion on CAPI and its use (4)

course, once the access latency of the OPENCAPI physical link (with BlueLink) is low enough, this allows the cache to be placed on the CPU side without compromising performance.This leads to the third question about CCIX, which uses PCIe as a physical line and does not know how to avoid the problem of too much delay!!!3) Q:capi and CCIX are using PCIe as the physical line, so latency will inevitably be large, ccix how to overcome? On which side is the CCIX cache? What is the difference between

Configure CPU temperature in ubuntu. fan speed and hard disk temperature monitoring

for 'Silicon Integrated Systems SIS5595 '... NoProbing for 'via VT82C686 Integrated Sensors '... NoProbing for 'via VT8231 Integrated Sensors '... NoProbing for 'amd K8 thermal sensors '... NoProbing for 'ipmi bmc kcs 'at 0xca0... NoProbing for 'ipmi bmc smic 'at 0xca8... NoSome Super I/O chips may also contain sensors. We have to writeStandard I/O ports to probe them. This is usually safe.Do you want to s

Red Hat Cluster Suite Cluster Oracle Database

fiber is not removed, only the local hard disk is selected during the partitioning process, rather than the disk array. Two NICs of each node connect to the vswitch through a standard network cable. Note: 1. Because the rhel-4-u2-rhcs-emt64 does not yet support the rsa ii Remote Management Card, and IBM does not provide the driver for rsa ii for Redhat As4 update2 or later versions, IPMI is used as the fence device of the cluster to avoid unexpected errors due to driver mismatch. IPMI is also a

General method of chip startup debugging

preceding checks, theoretically the CPU should be able to take the finger for execution. To better track the startup process and identify and analyze the symptoms and causes of startup failure in time, you need to initialize the serial port, seven-segment digital tube, or gpio/LED lamp in the BIOS as soon as possible, in addition, print the output of each important startup step in the bios, or click the LED light and display the agreed output in the 7-segment digital tube. Of course, if the sys

RedHatClusterSuite cluster Oracle Database

array before this installation. Therefore, the disk array configuration is not described in this document. Iii. Redhat As4 update2 installation Configuration Redhat is newly installed for the server, and the server is dedicated to oracle. (1) create a drive floppy disk based on the driver provided by IBM. (2) Configure BMC Select [F1] As prompted during system boot of the two hosts, enter BIOS, select advance config, set

IPMI from drive to Application (medium)

IPMI from drive to Application (medium )In the previous article, we talked about the IPMI underlying hardware connection and the implementation of the kernel driver, which facilitated the application developer by simply opening the operation with standard device files and invoking the available IOCTL to the BMC Send the request or read the response result.In addition to using this approach, application development engineers can leverage existing open

CentOS installation lm_sensors temperature monitoring

retrieved, amongst other things.42We first try to get the information from SMBIOS. if we don't find it43there, we have to read from arbitrary I/O ports to probe for such44interfaces. this is normally safe. do you want to scan for IPMI45interfaces? (YES/no): yes46Probing for 'ipmi bmc kcs 'at 0xca0... no47Probing for 'ipmi bmc smic 'at 0xca8... no48 49 Some hardware monitoring chips are accessible through t

Introduction of Foreman Architecture 7-foreman combined with mcollective to complete push action

#validoptionsare#warn,debug, Error,Fatal,INFO,UNKNOWN:log_level:DEBUG #开启debug模式, display more detailed information, use when troubleshooting. The default is open before version 1.5 [[emailprotected]yum.repos.d]#tailf/var/log/foreman-proxy/ proxy.logi,[2014-12-17t16:27:43.148519 #24337]info--: ' Foreman_proxy ' settingswereinitializedwithdefaultvalues::enabled:trueW, [2014-12-17t16:27:43.155592 #24337]warn--:couldn ' tfindsettings file/etc/foreman-proxy/setTings.d/facts.yml.usingdefaultsettings.

The life course of a c&c++ program

Turned a lot of blog, content points, did not find what I want, now absorb the essence of the great God, plus my humble opinion, summarized as follows:A C or C + + program from the beginning you write, to the end, the whole process, what has been done, see below:First look at the general process: look at the picture:The main thing I want to say here is what the program has done at each stage, and this is sometimes important, for instance:#define BSC//#define

How to troubleshoot server failures

return, the maintenance engineer brought the latest CPU management board (CPU Management Control) firmware (firmware), then upgraded the CPU management plate firmware, the server returned to normal immediately. Firmware upgrade method is, 1 use floppy disk to start the computer, and then insert firmware floppy disk and run the relevant file Cabrillo above; 2 The system refreshes the BMC (motherboard controller) and HSC (Hot-swappable backplane Contr

Problems and workarounds that cluster management may encounter (ongoing updates ...) )

1. Create an account First create an account: Useraddxxx #xxx为用户名 passwd xxx Then CD to the NIS environment directory, perform make, synchronize other node accounts Cd/var/yp Make This is the account that is available for all compute nodes Implement SSH without password login (if required): Switch to XXX account: Su xxx ssh-keygen-t RSA #回车三次 Ssh-copy-id localhost #回车输入密码即可 Complete 2. If the management node freezes Need to log in to BMC IP to

Oracle 12c RAC Setup

SuiteRpm-q--QF'%{name}-%{version}-%{release} (%{arch}) \ n'binutils Compat-libstdc++- -Compat-libstdc++-296elfutils-libelf elfutils-libelf-develGCC GCC-c++glibc glibc-Common glibc-devel glibc-headers Libaio Libaio-devel LIBGCC libstdc++LIBSTDC++-devel Makesysstat UnixODBC UnixODBC-develYum Install binutils.x86_64 compat-libcap1.x86_64 compat-libstdc++-. x86_64 compat-libstdc++-33 gccgcc make sysstat.x86_64 unixodbc.x86_64 unixodbc.i686 unixodbc-devel.x86_64 unixodbc-devel.i682.1.3. Shutting do

Encoding switch test OK Chen

[Plain]BMA = P4 ^ 2; // encoding switch A pin 1 // must be connected with A pulling resistance of 680 EuroSbit BMB = P4 ^ 3; // code switch B Pin 3 // must be connected with a pulling resistance of 680 Euro// Encoding switch pin 2 groundedSbit BMC = P1 ^ 6; // code switch c press the pinUnsigned int counter = 0; // encoder Pulse Count/*************************************** *******************Scan encoder sub-function by ChenForward (clock direction)1

I²c from drive to application (previous)

The I²c (intel-integrated circuit) bus is a two-wire serial bus developed by Phliphs Corporation to connect peripherals and microcontrollers. The application is very extensive, can use in the connection E2rom to save the various interface card, the monitor ROM information, may also use in the BMC to connect various temperature, the voltage, the current and so on the sensor, may also use to connect the memory stripe DIMM, uses to obtain the memory bar

IPMI setup under CentOS

1. Load the IPMI-enabled system moduleModprobe Ipmi_msghandlerModprobe ipmi_devintfModprobe Ipmi_poweroffModprobe Ipmi_siModprobe Ipmi_watchdog??Write the above command to/etc/rc.local to load the module automatically?????2. View IPMI Device Information# More/proc/devices | grep Ipmidev253 Ipmidev #有这一行说明有IPMI设备?????3. Create a character device node so that Ipmitool can access the IPMI system interface through the driver, which typically saves# Mknod/dev/ipmi0 C 253 0Mknod: '/dev/ipmi0 ': File a

O & M platform-based Cobbler and ipmi automated Installation Platform

motherboard voltage. 2. Check the power status, and remotely shut down and start the instance. 3. Remotely specify the boot sequence 4. Remote view. This function is based on ipmi to improve bmc to implement the kvm function Keyboard, Video, and Mouse) 5. Remote Text View 1. First, view and configure the ip address and user information. ipmitool-H ip-U user-P xxxx lan print 1 #1 indicates the network lan. The default value is 1, when running the com

Server disconnection guide-how to build a Test Platform

overclock, but servers can only reduce the frequency and not exceed. In addition, the CPU and Xeon series in the same period are much more expensive than the home-level I3 I5 I7, which is very cost-effective. Understanding servers is actually to learn about redundant memory, redundant hard disks, redundant CPUs, redundant power supplies, and BMC remote management. It can be said that the household machine is a high startup, but the base is thin and

CentOS installation lm_sensors Temperature Monitoring

): yes46Probing for 'ipmi bmc kcs 'at 0xca0... no47Probing for 'ipmi bmc smic 'at 0xca8... no48 49 Some hardware monitoring chips are accessible through the isa I/O ports.50We have to write to arbitrary I/O ports to probe them. this is usually51safe though. yes, you do have isa I/O ports even if you do not have any52ISA slots! Do you want to scan the isa I/O ports? (YES/no): yes53Probing for 'national semic

Total Pages: 12 1 .... 5 6 7 8 9 .... 12 Go to: Go

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.