cisco 3750 switch

Read about cisco 3750 switch, The latest news, videos, and discussion topics about cisco 3750 switch from alibabacloud.com

[Cisco] DHCP relay, layer-3 Switch VLAN Routing Practice

[Cisco] DHCP relay, layer-3 Switch VLAN Routing PracticeThe experiment topology uses the GNS3 0.8.6 simulator to build a DHCP server using Red Hat 6.5. The experiment requires configuring a layer-3 Switch VLAN routing so that VLAN10 and VLAN20 members can access each other. Performs DHCP relay for layer-3 switches so that VLAN10 and VLAN20 members can obtain IP a

Cisco 3550 Switch configuration (1)

For complete syntax and application information about this chapter, seeCatalyst 3550 Multilayer Switch Command ReferenceAnd Cisco IOS Interface Command Reference For Release 12.1. Understanding Interface Types This section describes different interface types and some reference content for configuring these interfaces in detail in other sections. Other sections describe the configuration process of physi

Cisco switch, inter-vlan routing, and nat address translation

I am eager for the first time to switch between vlan routing and nat addresses of Cisco switches. I am very energetic and have an undefeated spirit. I am ready to continue to answer questions during multiple rounds of interviews. My little brother squashed his eyes and took out the bottom of the press box: If my company has two Internet interfaces, A and B, respectively. The following vswitch divides multip

Cisco switch speed limit Summary

Cisco switches enable port speed limiting As shown in, Node switch 3550 is placed in an office room. The networks of all office companies are from this place. How does the operator configure network bandwidth settings for each company on this device? Let's take the IT Training Center of XX foreign companies as an example. The IT Training Center of XX foreign companies applied for a 2 m link. Step-1 Rongxi

Centos 6.2 Nic aggregation and Cisco switch link Aggregation

protected] bonding] # ethtool EM2Settings for EM2:Supported ports: [TP]Supported link modes: 10 BaseT/half 10 BaseT/full100 Baset/half 100 Baset/full1000 Baset/fullSupports auto-negotiation: YesAdvertised link modes: 10 BaseT/half 10 BaseT/full100 Baset/half 100 Baset/full1000 Baset/fullAdvertised pause frame use: NoAdvertised auto-negotiation: YesSpeed: 1000 MB/SDuplex: fullPort: Twisted PairPhyad: 1Transceiver: InternalAuto-negotiation: OnMDI-X: UnknownSupports wake-on: GWake-on: dLink detect

Cisco Router switch Configuration command detailed

trunkSwitch (config-if) #switchport trunk allowed VLAN, set allowed VLANsSwitch (config-if) #switchport trunk encap dot1q; set VLAN trunkingSwitch (config) #vtp domain; Set the VTP domain nameSwitch (config) #vtp password; set the VTP passwordSwitch (config) #vtp mode server, setting the VTP patternSwitch (config) #vtp mode client, setting the VTP patternSwitch set IP address:Switch (config) #interface vlan 1; go to VLAN 1Switch (config-if) #ip address; Set IP addressesSwitch (config) #ip defau

Initial configuration of the Cisco switch (login with telnet)

Experimental requirements: Use Telnet login to complete the initialization configuration of a switchTopology diagram1. Enter the command line of the switch2. Enter enable into privileged mode3. Enter configure terminal into global mode4. Enter hostname Ruan Change host name to Ruan (here the hostname is just as good as you remember)5. Enter enable password 1314 to set the plaintext management password to 13146. Enter enable secret 520 to set the encryption management password to 520 (note here t

Network Foundation Cisco Routing switch One

) #interface range F0/1-2 (check 1.2 port number)Switch (config-if-range) #switchport Access VLAN 3 (Connect 1.2 ports to VLAN3)Interface joins VLAN:Switch (config) #interface fastethernet 0/1 (enter Port 1th)Switch (config-if) #switchport Access VLAN 2 (Configure the 1th interface into vlan2)Trunk Trunk Link:Implement VLAN communication across switchesTrunk links can host multiple VLANsIdentity of the VLAN

Quickly restore Cisco Route switch IOS

With the development of China's routing industry, we have also promoted the update and upgrade of the routing switch technology. Here we have introduced the IOS restoration method of the Cisco routing switch, and we have tried one method, after Flash is deleted, the system cannot be started. You can use X-Modem to restore it. At that time, I accidentally deleted

How to configure a Cisco router as a Frame relay switch

Experimental topology Router (config) #frame-relay switching to simulate a router as a Frame relay switch Router (config) #inter S1/1 Router (config-if) #clock rate 128000 Router (config-if) #encapsulation Frame-relay Configuration Interface encapsulation and binding relay The default Frame relay enabled on the interface is encapsulated in the Cisco package and, if connected to a non-

Cisco 3560 switch interface traffic grabbing vbs script

Cisco 3560 switch interface traffic grabbing vbs scriptTo make it easy for you to view the traffic of the vswitch interface, the customer does not log on to the vswitch, and does not have any network management traffic statistics device. Simply write a vbs script, which is simple and usable. On error resume next dim wshellset WshShell = WScript. createObject ("WScript. shell ") WshShell. run "cmd" WshShell

Cisco switch port broadcast storm settings

Cisco switch port broadcast storm settings are more practical. When a port receives a large number of broadcast, unicast, Or multicast packets, a broadcast storm occurs. Forwarding these packets will slow down the network or cause timeout. Using broadcast storm control on ports can effectively avoid network paralysis caused by hardware damage or link failure. By default, broadcast, multicast, and unicast st

Using the Gigabit module on the Cisco 4507 switch engine

No X2Input Flow-control is off, output Flow-control is offARP Type:arpa, ARP Timeout 04:00:00Last input never, output never, output hang neverLast clearing of "show interface" counters neverInput queue:0/2000/0/0 (size/max/drops/flushes); Total Output drops:0Queueing Strategy:fifoOutput Queue:0/40 (Size/max)5 minute input rate 0 bits/sec, 0 packets/sec5 minute output rate 0 bits/sec, 0 packets/sec0 packets Input, 0 bytes, 0 no bufferReceived 0 broadcasts (0 multicasts)0 runts, 0 giants, 0 throt

Enterprise Network Cisco switch DHCP snooping and IP source guard prohibit manual IP configuration

----------- --------------------------------------------------------GI1/0/1 Ip-mac INACTIVE-NO-SNOOPING-VLANGI1/0/2 Ip-mac Active Deny-all deny-all 24GI1/0/3 Ip-mac INACTIVE-NO-SNOOPING-VLANGI1/0/4 Ip-mac Active Deny-all deny-all 24GI1/0/5 Ip-mac Active Deny-all Deny-all 24GI1/0/6 Ip-mac Active deny-all deny-all 24GI1/0/7 ip-mac AC tive 172.16.24.150 a4:4c:c8:10:63:ee 24gi1/0/8 ip-mac INACTIVE-NO-SNOOPING-VLANGI1/0/9 Ip-mac Active Deny-all deny-all 24GI1/0/10 ip-mac IN

Cisco launches a new multi-layer smart optical fiber switch

High intelligence, high availability, and high reliability are the characteristics of multi-layer intelligent optical fiber switch. Although its technology is not very mature yet, it has been recognized by people. Cisco Systems recently announced that it will launch the CiscoMDS9100 series of multi-layer smart Optical Fiber switches this fall to meet the needs of small and medium-sized enterprises for deplo

Cisco switch Port Aggregation configuration

The port rate between switches and switches, between switches and routers, does not meet the actual rate and requires tying more than two ports together to load balance and prevent single points of failure.1. Select Switch SW2960 to configure the F0/1 and F0/2 port modes to truck#conf Terminal into privileged mode#interface Range Fa0/1–2 used to bind a set of ports and enter the port batch configuration view Figure#switchport mode truck will figure p

Cisco Catalyst 6500 Series Switch Denial of Service Vulnerability (CVE-2015-0771)

Cisco Catalyst 6500 Series Switch Denial of Service Vulnerability (CVE-2015-0771)Cisco Catalyst 6500 Series Switch Denial of Service Vulnerability (CVE-2015-0771) Release date:Updated on:Affected Systems: Cisco catalytic 6500 Description: Bugtraq id: 75063CVE (CAN) ID:

Cisco switch password settings

Cisco switch password settings www.2cto.com 1. set console password> enable # configure trminal (confing) # line console 0 secure console port ① (config-line) # password (cisco) Secure password (config-line) # login logs must not be small. console Password settings complete exit 2: set the global password www.2cto.com enadle # configure terminal ② (config) # enab

Cisco LAN switch maintenance and configuration application skills (1)

Overview of LAN switches LAN switches have evolved from a HUB-based LAN shared in the traditional sense to a broader space. Take Cisco's Catalyst 5000 Series LAN switch as an example. It includes an integrated switching hardware structure, 10-Mbps Ethernet that supports switching, and-Mbps Fast Ethernet, supports fast Ethernet, FDDI, exchange-type ring, and layer-3 switching processing. This type of switch

Cisco switch status light solution

Cisco switch status lights are all available on the front panel of the Cisco switch and are used to monitor system activity and performance. These LEDs are called LEDs ).The indicators on the front panel include: · system indicator www.2cto.com · remote power supply indicator · port mode indicator · Port Status Indicat

Total Pages: 10 1 .... 6 7 8 9 10 Go to: Go

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.