Cisco, Huawei Switch OID get

To monitor the switch port traffic, status, CPU utilization, memory status, temperature, etc., the key is to find the corresponding OID, this article will discuss with you how to get Cisco and Huawei Switch OID, the method is the same, we can extrapolate.One, the acquisition of the Cisco

Get the OID value of a Cisco device

1, first landing equipment, check the device version;2, open the URL:https://www.cisco.com/c/en/us/support/web/tools-catalog.html, select Launch MIB Locator;3. Jump Web page, click Cisco IOS MIB Locator;4, jump page, enter version information, according to the SNMP version used to select the corresponding v1 or v2, to find the corresponding OID library ;5. In the OID

Device location in SNMP-based Cisco Network Environment

Background: 1. The relationship between the IP address and the MAC address in the ARP table of the layer-3 device. 2. the forwarding bridge table of the L2 device stores the correspondence between MAC and forwarding ports. 3. CDP (Cisco Discovery Protocol) is the link layer protocol for discovering adjacent devices between Cisco devices. 4. The forwarding table in the layer-2 module of a layer-3 swi

In Ubuntu, CentOS, and Cisco, how does one configure SNMPv3?

Group-name: v3Group Snmpwalk in any Linux device can be used to verify the configuration and check the output. Snmpwalk-u snmpv3user-A snmpv3pass-a MD5-l authnoPriv 192.168.1.3-v3 Iso.3.6.1.2.1.1.1.0 = STRING: "Cisco IOS Software" Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2012 by Cisco Systems, Inc. Iso.3.6.1.2.1.1.2.0 = OID: iso.3.6

Add SNMP ++ to vc6.0

With the successful compilation of the last snmp_pp.lib file, I learned more about SNMP ++. This is to learn various types of SNMP ++ software packages, they are OID, IPaddress, udpaddress, VB, PDU, and SNMP, in the end, we can use SNMP ++ to perform SNMP operations (such as get) on network devices that support SNMP management (such as Cisco switches ).I. Self-entertainment

CISCO PIX Firewall System Management (2)

DHCP server. The Debug DHCPC command provides error-correcting tools for the boot DHCP client feature. The PIX firewall commands that are used to implement the DHCP client are described in the IP Address command page and the Debug command page of the Cisco PIX Firewall Command Reference. Please see these command pages for specific information.Note the IP address of the external interface required by DHCP can also be used as the PAT Global address. Th

Zabbix 3.0 Monitoring Switch (3)--CPU, memory monitoring and configuration trigger

The key to monitoring the CPU and memory of the switch is to find the correct OID, please refer to the following blog post for how to find the OID.http://tryrus.blog.51cto.com/10914693/1788833Before looking at this blog post please make sure that you have an understanding of the basic operation of Zabbix, there is no clear place to read my previous blog post.http://tryrus.blog.51cto.com/10914693/1772271http://tryrus.blog.51cto.com/10914693/1782062Firs

Slime: Using Snmpwalk to capture device OID information

This article by show according to Lin Feng to provide friendship sponsorship, starting in the mud row world. Planning to start learning about monitoring, but now a lot of monitoring systems are based on SNMP. and SNMP monitoring performance indicators are through the Snmpwalk acquisition device OID Information obtained, so today to introduce, how to collect the OID information of the device through Snmpwalk

Rotten mud: Use snmpwalk to collect device OID information, snmpwalkoid

Rotten mud: Use snmpwalk to collect device OID information, snmpwalkoid This article was sponsored by Xiuyi linfeng and first launched in the dark world. I plan to start learning about monitoring, but now many monitoring systems are based on SNMP. Many performance indicators of SNMP monitoring are obtained by collecting device OID information through snmpwalk. So today we will introduce how to collect devi

Zabbix Monitoring Switch settings

int value in the Interface tab, view the OID value of the port on the current switch, and then use the OID value in Zabbix to monitor the switch port.The ports and OID values for Cisco switches are listed here1. C3750E PortIfinoctets #进口流量1.3.6.1.2.1.2.2.1.10. Ifoutoctets #出口流量1.3.6.1.2.1.2.2.1.16. 1 Vlan15179 StackPo

Zabbix Monitoring Switch Setup method _zabbix

value in the Interface tab, view the OID value of the current switch's port, and then use the OID value to monitor the switch port in Zabbix. Here is a list of the ports and OID values of several Cisco switches 1, c3750e Port Ifinoctets #进口流量1.3.6.1.2.1.2.2.1.10. Ifoutoctets #出口流量1.3.6.1.2.1.2.2.1.16. 1 Vlan1

Zabbix Monitoring switch setup steps in Linux

Interfaces.iftable.ifentry.ifinoctets.1 corresponds to the Vlan1 interface of the switch, the OID value is: 1.3.6.1.2.1.2.2.1.10.1 interfaces.iftable.ifentry.ifinoctets.5179 corresponds to the StackPort1 interface of the switch, the OID value is: 1.3.6.1.2.1.2.2.1.10.5179 interfaces.iftable.ifentry.ifinoctets.10101 corresponds to the GIGABITETHERNET1/0/1 interface of the switch,

Ubutun Uninstall PHP expansion

) Did not find ' ucdexperimental ' in Module Ucd-snmp-mib (/usr/share/snmp/mibs/ucd-dlmod-mib.txt) Unlinked OID in Ucd-dlmod-mib:ucddlmodmib:: = {ucdexperimental} Undefined identifier:ucdexperimental near line of/usr/sh Are/snmp/mibs/ucd-dlmod-mib.txt cannot find module (SNMPV2-TC): At line In/usr/share/snmp/mibs/lm-sensors-mib.txt Did not find ' displaystring ' in Module #-1 (/usr/share/snmp/mibs/lm-sensors-mib.txt) Did don't find ' ucdexperimental '

Slime: Using Snmpwalk to capture device OID information

this article starting at Slime Line the world . Planning to start learning about monitoring, but now a lot of monitoring systems are based on SNMP. and SNMP monitoring performance indicators are through the Snmpwalk acquisition device OID Information obtained, so today to introduce, how to collect the OID information of the device through Snmpwalk.To use Snmpwalk to capture the

[Reprinted] rrdtool Chinese manual-Quick Start (2)

= "loopback0" For Cisco devices, I want to monitor the 'ethernet0' interface. From the above output, we can see that the interface number is 4. I tried to run the following command: [User @ host/home/Alex] $ snmpget-v2c-C public Cisco 2.2.1.10.4 2.2.1.16.4 Interfaces. iftable. ifentry. ifinoctets.4 = 2290729126Interfaces. iftable. ifentry. ifoutoctets.4 = 1256486519 In this way, I have two

Linux SNMP commands and application instances (1)

. ifDescr.2 = "BRI0: B-Channel 2" interfaces. ifTable. ifEntry. ifDescr.3 = "BRI0" Hex: 42 52 49 30 interfaces. ifTable. ifEntry. ifDescr.4 = "Ethernet0" interfaces. ifTable. ifEntry. ifDescr.5 = "Loopback0" for cisco devices, I want to monitor the 'ethernet0' interface. From the output above, I can see that the interface number is 4. Run the following command: [user @ host/home/alex] $ Linux SNMPget-v2c-c public

Crack two network management software keys of eduwitt

, especially during troubleshooting.With manageengineoputils, you can repair network problems, such as network connectivity, availability, running status, and the waiting time of any IP node in the network. The software also allows custom tools to manage DNS names, IP addresses, and MAC addresses, and obtain information such as CPU, memory, and software list. The SNMP tool can be used to monitor any IP nodes that support SNMP. The Cisco tool is used t

Knowledge about Linux SNMP and RRD database updates

" interfaces.ifTable.ifEntry.ifDescr.3="BRI0"Hex:42524930 interfaces.ifTable.ifEntry.ifDescr.4="Ethernet0" interfaces.ifTable.ifEntry.ifDescr.5="Loopback0" For cisco devices, I want to monitor the 'ethernet0' interface. From the above output, we can see that the interface number is 4. Run the following command: [user @ host/home/alex] $ Linux SNMPget-v2c-c public cisco 2.2.1.10.4 2.2.1.16.4 in

Network engineer software SolarWinds Tools function Introduction

Monitor monitors a variety of detailed networking states for multiple routing devicesNetperfmon database maintenance for maintaining the databases generated by the tools aboveSNMP Graph is used to collect detailed data of the set OID in a timely manner in the MIB.Bandwidth Gauges Monitor the path and bandwidth of remote devices in the form of metersBandwidth monitor channels and bandwidth of multiple devices in a timely fashion with trend graphsAdvan

Zabbix 3.0 Monitoring Switch (4)-temperature, fan monitoring and configuration trigger

slightly different, create the item directly above the switch type template, as shown in.Name,key these two values can be filled in casually, but it is better to be like me, can be very intuitive to know what this item is monitoredTYPE:SNMP v2 VersionSNMP OID: the corresponding OIDSNMP Community: The corresponding SNMP read group wordUnits: Unit of temperature ℃The other options are default, and the last item description fills in the description when

Total Pages: 15 1 2 3 4 5 .... 15 Go to: Go

Alibaba Cloud 10 Year Anniversary

With You, We are Shaping a Digital World, 2009-2019

Learn more >

Apsara Conference 2019

The Rise of Data Intelligence, September 25th - 27th, Hangzhou, China

Learn more >

Alibaba Cloud Free Trial

Learn and experience the power of Alibaba Cloud with a free trial worth $300-1200 USD

Learn more >

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.