Siemens PLC Learning note 11-(Loading and delivery instructions)

) format into the accumulator 1, or the specified counter's current count value in the BCD code (0~999) format into the accumulator 1. Instruction format: LCLC T3 //The current time and time base of Timer 3 is loaded into the accumulator 1 Low character LC C10 //The counter C10 count value is loaded into the accumulator 1 low word in BCD code format8.MOVE instructionThis instruction is a function box in the form of a transfer instruction, the ability to copy byte, Word or double-word data

Siemens PLC Learning note 18-(with parametric FC programming)

With parameter FC, when editing the function, define the formal parameter in the local variable declaration table, and use the virtual symbolic address in the function (FC) to complete the program writing.Here's a simple example of how to write a parameter FC function.This example completes the programming of a mathematical formula: Y = (X + 5) * 11/5;The procedure is as follows:The FC mathematical formula is written as follows (internally defined input parameter variables: x and output paramete

Siemens PLC Learning Note 16-(Structure of logical blocks)

duplex data type, or a parameter type that is specifically used for parameter passing, such as a timer, a counter, an address or a pointer to a block, and so on.3. How to use variables1) Use the variable name, preceded by the prefix "#", to distinguish it from the symbolic address in the symbol table. In incremental mode, the prefix is automatically generated.2) directly use the address of the local variable, which is only valid for the background data block and the L stack.In addition, when ca

Anti-interference capability of PLC

Why is PLC so reliable?This is not a simple question. You should answer clearly not one or two articles. Here, I have been a chief engineer of stiplc for many years.Exchange experience with friends:1. What content does reliability include?Reliability means that the product can accurately complete all the designed functions under the specified conditions. Electronic products generally include:(1) Mechanical Properties(2) Electrical Performance(3) Therm

Float examples and plc programming examples

Float examples and plc programming examplesFloat instance description Float is a powerful attribute. In the actual front-end development process, people often use it for layout. However, sometimes, it is difficult to use it. For example, now we want to implement a two-column layout, with the left column fixed in width, and the right column automatically expanded in width. See: Idea: Use div + float, div1 as the column on the left, div2 as the column

Twincat (Balford Beckhoff) Frequently asked Questions (FAQ)-How to get different PLC programs to run on separate threads TC2

In a task configuration, create a new task that can set the name and scan period?Right click on the Task,append program call and find the PRG written in the main application.?Run no problem, SUB1 collect the data of the Y variable of main once every second??For more instructional videos and downloads, please pay attention to the following information:My Youku Space:Http://i.youku.com/acetaohai123?My online forum:http://csrobot.gz01.bdysite.com/?Problem Exchange:qq:910358960Email:[email protected

Siemens PLC Learning note Five-(programming language, data type)

: Motor:structSpeed:intCurrent:realEnd_structC. StringString strings are a one-dimensional array of up to 254 characters (CHAR), with a maximum length of 256 bytes (the first 2 bytes are information that stores the length of the string). such as ' I ' M is string 'D. Date and timeThe date and time (Date_and_time) is used to store the year, month, day, hour, minute, second, millisecond, and week, accounting for 8 bytes, saved in BCD format. Week 1~7 represents Monday to Sundaysuch as: dt#2014-09-

Tech PLC Development-chat window Chinese Input Keyboard location change

In the viewdidiload method [[Nsicationcenter center defacenter center] addobserver: Self selector: @ selector (keyboardwillshow :) name: uikeyboardwillshownotification object: Nil]; [[Nsicationcenter center defacenter center] addobserver: Self

When the COM1 port is occupied, RS232 cannot connect to Siemens plc.

 * COM is displayed in the PC adapter that sets the pg/PC interface in Step 7. Indicates that the comport is replaced by another ProgramOccupied. When kepserverex4.0 is used, when the Siemens S7 MPI device driver is used, the COM1 port is prompted

PLC Ladder Diagram Design

Traffic light Control In a scenario like this, when the SW1 switch is turned on, the traffic light controller starts to work and the controller stops working when the SW1 is turned off.SW2 for control mode selector switch:When the SW2 is turned

SerialPort access COM interface to obtain PLC Data

Using system;Using system. Io. ports;Using system. text;Using system. Threading; Namespace weight{/// /// Electronic scaling Interface Information Class, encapsulation of comport data/// Public class weightinformation{String _ wdata;String _ wunit;

PLC _ Automation Control System _ 1 _ Automation Control System in short

I have mentioned some texts about the SCL Of The SIEMENS Automatic Control System some time ago. I suggest you briefly introduce the automatic control system here. Here I will give a brief introduction, in fact, we often see automated control in our

How to install Mitsubishi PLC programming software?

1. First, you need to extract the downloaded installation package to the specified folder. 2. Then need to install the environment on the computer, open the Environment installation file, and then double-click the "Setup" file

ETHERNET/IP of the introduction of industrial safety

of devices exposed IP fields were different from the actual scanned IP addresses. So we come to the conclusion that most ETHERNET/IP devices are deployed in the internal network rather than directly exposed to the Internet. As shown in 5?15, using Nmap to scan the Compactlogix control system scan results, you can see the exposed device IP and scan IP mismatch, indicating that the target system is located behind the router or firewall.Shows some infor

Development trend of industrial computer

control system is still developing. Due to the development of open structure and integration technology, the sales of large-scale decentralized control systems have been increased. DCS1997 Annual sales of $4.5 billion, 2000 to $6 billion.   The world's major DCS suppliers are: Honeywell, Bailey, Westing, House, ABB, Foxboro, Ln, Siemens, EuRo, Yokogawa, Japan Mountain Wu Honnavire and so on. DCS is one of the most affected and fastest reaction in computer industry.   The main development trend

IFIX System Configuration Guide

To help System Engineers and pre-sales service engineers better use iFIX and its components to configure enterprise-level systems, this document provides detailed descriptions and examples in various aspects, for reference by project personnel. This document covers the following topics: Device connection, iFIX function module selection, database design, network design, enterprise information system and resource scheduling system integration, and redundant system design.Chapter 1 device connectio

6.PMAC slave-Lower machine programming

The lower machine programming of PMAC consists of three programs: Command sequence program, motion program and PLC program.In the PMAC program, the file->new new file opens the editor and all the files are PMC suffixes. The current program can be viewed in the File->uplaod programs to view the current program and PLC programs and their number, status.1. Command sequence in the section, the PMAC card can use

Modbus protocol Finishing--function code description

study notes-via Modbus TCP control Gpio "--i.mx287+freemodbus modbus TCP" Modbus learning notes--modbus TK modbus TCP host Implementation "1.MODBUS function code descriptionThe following table lists some of the function codes supported by Modbus: in decimal notation.Table 1.1 Modbus part function code Code Chinese name Register PLC Address Bit manipulation/word manipulation Number of operations 01

Communication between VB and Siemens S7-200 (PPI protocol)

1. You can write and read the register values (byte, word, and dual-word ); 2. You can set and reset components (v, M, S, Q, And I; 3. the on/off status of the component (v, M, S, Q, And I) can be read. 4. PLC Operation and stop can be controlled. Published the popular PPI protocol on the Internet. Although this protocol is incorrect, the idea is correct. There are many ways to communicate between Siemens S7-200

S7-200 PLCRS485 Interface

I. RS485 interface circuit diagram inside the S7-200PLC: see the attachment for circuit diagram In the figure, R1 and R2 are common resistance with a resistance of 10 euro. Their function is to prevent the generation of an over-current burned-out chip when the RS485 signal D + and D-short circuit are used. Z1 and Z2 are the 6 V clamping voltage, zonea diode with a maximum current of 10A. The 24 V power supply and the 5 V power supply are not isolated. When the common mode dry disturbance voltage

Total Pages: 15 1 .... 5 6 7 8 9 .... 15 Go to: Go

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.