Differences between optical transceiver and Optical Transceiver

One end of the optical transceiver is connected to the optical transmission system, and the other end is the 10/100 M Ethernet interface. Optical fiber transceiver achieves photoelectric signal conversion. The main principle of the optical transceiver is achieved through photoelectrical coupling. Optical Transceiver ge

Enterprise Networking and LAN Optical Fiber transceiver selection (1)

Nowadays, optical transceiver network devices are increasingly used in our network engineering. They are used in small-scale optical fiber trunk connection solutions, so it is better to use optical fiber interfaces for switches in large-scale optical fiber trunk. Because of the various types of optical fiber, wavelength, interface type, rate, and other technical indicators, a wide range of Optical Fiber transceive

Light Cat, photoelectric converter, fiber optic transceiver Three devices what is the difference

"Netizen asks a question": have been not clear exactly what difference does photoelectric converter, fiber transceiver, light cat, light module have? "Answer": Optical module is inserted in the router or switch, can not be used independently, belong to other devices part. and netizens mentioned (photoelectric converter, optical transceiver, light cat, optical module) A few things are basically one thing,

Design of ONU and transceiver module in E-pon

Absrtact: This paper introduces the technical requirements of E-PON (Ethernet passive optical network) system for ONU (Optical Network Unit) and the basic principle and design method of ONU transceiver module, and gives the experimental results. Keywords: e-pon;onu; burst; transceiver module; BiDi 1. Foreword With the rapid development of the information society, People's reliance on it becomes more and

Using Delphi to establish communication and data Exchange Server-transceiver Technical Analysis (i)

Introduction In the domestic common information development and implementation projects, most of the work of the development of the workload is concentrated in order to adapt to different customer needs, the specific modules to modify, and ultimately achieve customer expectations of the software functional characteristics. But for the development of vendors, in the face of different customers to develop different software versions, will lead to duplication of labor, cost rise, maintenance incre

Can transceiver pca82c0000and tja1040

1. Similarities 1.High-speed can transceiver, can reach 1 mbaud 2.Can all enter the standby mode 3.Both have strong anti-interference capabilities 4.Both features hot shutdown (overheating protection) 5.When txd (Pin 1) is high, the output bus is in the implicit (recessive) state. When txd is low, the output bus is in the dominant (dominant) state. 6.Differential voltage VI (DIF) = VCANH-VVANL, when vi (DIF)> 0.9v, the bus is dominant; VI (DIF) Ii. Di

Using Delphi to establish communication and data Exchange Server-transceiver Technical analysis (next)

Second, transceiver service detailed 1. Transceiver Service Analysis Summary Transceiver Service is the core of the transceiver system, transceiver kernel is responsible for reading the port, transceiver definition and parameter

Xilinx FPGA high-speed serial transceiver Introduction

of the signal, keeping the low-frequency signal, to compensate the transmission line attenuation of the signal, improve the performance of the eye graph and guarantee the transmission quality.3 Xilinx FPGA Transceivers3.1 system ArchitectureThe 7 Series FPGAs GTX and GTH transceivers is power-efficient transceivers, supporting line rates from $ MB/s to 12.5 GB/s for GTX transceivers and 13.1 Gb/s for GTH transceivers. Four Gtxe2_channel Primitives and one Gtxe2_common primitive to be a Quad.The

Using the python-twisted Library to implement a file transceiver service

= Open ('files/%s'% (Name_file,),'WB') except: Print 'Open%s fail!'%(Name_file,) self.handle_f_=None#self.transfer.loseConnection () Else: Self.setrawmode ()elif 'Get'==Self.command_: Self.size_remain_=0ifOs.path.exists ('files/%s'%(Name_file,)): Self.size_remain_= Os.stat ('files/%s'%(Name_file,)). st_size instruction= Dict (size_file=self.size_remain_)ifSelf.size_remain_>0:Try: Self.handle_f_= Open ('files/%s'% (Name_file,),'RB') except: Self

POP3, SMTP mail transceiver

") return false; } if (fputs ($this->socket, "$this->bodyrnrn") return false; } if (fputs ($this->socket, ". Rn") return false; } $this-> POP3, SMTP mail transceiver Publish time: September 28, 2001 read times: 18 recommended to friends print this page if ($EMAIL _inc) return; $EMAIL _inc= "defined"; Define ("Smtpport", 25); Class Pop3 { var $subject; Message subject var $from _email; Sender Address var $from _name; Sender Name var $to _email; R

What to pay attention to using optical transceiver

When using a fiber-optic transceiver, it is necessary to pay attention to some problems in order to make the use of fiber-optic transceiver better. 1. View whether full duplex or half-duplex is supported. Some of the market can only use a full dual public environment, can not support Half-duplex, such as receiving other brands of switches or hubs, and it uses Half-duplex mode, otherwise it will cau

Comparison and Analysis of Wireless Transceiver Chip Solutions

In the wireless data transmission system, the wireless transceiver chip is the core carrier of the technology. As the signal sending and receiving, modulation, and debugging, it plays an absolute core role. We will compare and analyze several Wireless Transceiver Chip Solutions. 1) CC1000 Wireless Transceiver Chip Solution CC1000 is a single-chip programmable RF

What is the meaning of the panel LEDs and switches on the tr-962d/932d of the optical transceiver?

Indication of the indicator meaning:Power (green): "Solid" indicates that the fiber transceiver is in power state;LFP indicator: "Solid" indicates that the LFP function is turned on, "normally extinguished" means that the LFP function is closed;Fx_link/act (green): "Solid" indicates that the fibre port connection is valid, "flashing" indicates that the transceiver is receiving or transmitting data from the

Design and implementation of transceiver management system based on ASP

Network Office has become the trend of modern enterprise development. This paper mainly expounds the function module of the transceiver management system based on B/s structure and how to use ASP and SQL Server to solve some related technologies, including the security of the system. Introduction Traditional manual Office is unable to meet the needs of modern office, transceiver management system as to impr

Realization of hexadecimal transceiver based on QT

Previous wrote a serial assistant with QT to do the blog post (based on Qt5.6 do a simple serial port with the transceiver function), do out of the serial assistant can only carry out the character of the transceiver, if the reception is the hexadecimal data, it will show garbled, and now on its basis to do some modification, so that the implementation of hexadecimal tr

STM32F0XX_DMA Transceiver Usart Data Configuration detailed procedure

ObjectiveAbout the function of DMA (Direct Memory Access), the people who are concerned about me should know that I have briefly spoken on the F1 chip. There are netizens asked to explain in F0 the use of DMA transceiver serial data. Today should be a user request to summarize on the F0 chip, the use of DMA transmission (transceiver) Usart data functions.In a variety of chips (F0, F1, F2, F3, F4) know the f

The single-chip microcomputer is based on the wireless communication of the 4G wireless transceiver module nrf24l01 (basic test passed)

In wireless communication, the nrf24l01 wireless transceiver module produced by Nordic is the choice of many players. It is GHz ~ The single-chip wireless transceiver chip in the GHz ISM band has the advantages of strong functions, convenient control, and low price. One piece of nrf24l01 can receive data sent from six channels at the same time, and change the communication channel to avoid wireless communic

NI pxie-5644r vector Signal Transceiver hardware architecture

http://xilinx.eetrend.com/article/7471With the advent of the NI pxie-5644r vector signal transceiver (VST), ni reshaped the concept of the instrument by introducing the flexibility of the user-programmable FPGA into the RF instrument.1. High performance and revolutionary designNI pxie-5644r VST combines typical RF I/O functions in a vector signal analyzer (VSA) and vector signal Generator (VSG) with NI or user-defined functions for signal processing a

A CANBus Tiny Network without transceiver Ics:stm32f4 Discovery

Sometimes you have a can equipped processor in a low cost board but it has no CAN transceiver chips.Here is a method, the can be used to create a small experimental network with such a board.There'll is no noise immunity and you might has to lower the speed ....But many experimenters has made this work satisfactorily.Use a signal diode similar to 1n914 or 1N4148.Power supply diodes usually do not has a fast enough recovery time for CAN to function.Mod

dm9000 Network Port Transceiver control and MAC address filtering settings

Objective: To complete the network Port transceiver debugging process: NBSP;NBSP;1, network port initialization, according to the chip data sheet configuration 2, the number of network port, first to the TX FIFO in DM9000 to the data, and then sent to send the register to complete the sending; 3, network port reception. 1) Interrupt mode: DM9000 interrupts can be queried by proactively querying the DM9000 interrupt register, and by interrupting th

Total Pages: 15 1 2 3 4 5 .... 15 Go to: Go

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.