ISUZU 8971891360 (16267710/1.7l EDU) repair solution with pinout, pictures and explanations!Check the CapacitorsCheck the transistorRedo soldering (90% of fault)"If your Astra 1.7 Diesel with an Isuzu engine have problems starting, stalling, or just does not run, the usual problem is The Diesel I ECU becoming faulty. Symptoms is complete non start or a spurious fault code blaming the spill valve.We can now repair the problem and get car up and running
Something about parallel interfaces.
This is about paralllel port (db25) comnector.
Introduction
Hi there, I was searching the web for a way to allow me to control electrical appliances using PC and I found it here. here is a circuit (figure 1) for using the printer port of a PC, for control application using software and some interface hardware. the interface circuit along with the given software can be used with the printer port of any PC for contr
RS-232C interface definition (DB9) PIN definition symbols 1 Carrier Detection DCD (data carrier detect) 2 receive data rxd (received data) 3 send data txd (transmit data) 4 data terminal prepare DTR (Data Terminal ready) 5 signal SG (signal ground) 6 data prepare DSR (data set ready) 7 request to send RTS (request to send) 8. Clear send CTS (clear to send) 9. The ring indicator prompt is Ri (ring indicator)1. description of common signal ports of DB9 and db2
During the experiment, we usually use the serial port to connect two routers. But what should I do if my serial port is used up? You can also use the aux port to connect two vrouters using PPP.
We know that a router generally has an aux port. There are two interface types: RJ45 (for example, 25 series and 26 series ), another type is DB25 (for example, 45 Series and 7000 Series). aux is a DTE device, so two DTE devices need to be connected using a rol
understand the Java in the serial communication
Technology is also necessary, perhaps a reader who would like to use this technology to write a PDA and computer data sharing process
Preface it.
This article mainly to RS232 to explain the Java serial communication technology.
RS232 Communication Basics
Rs-232-c (also known as EIA Rs-232-c, hereinafter referred to as RS232) was in 1970 by the American Electronics Association (E
IA) Joint Bell System, modem manufacturer, and computer terminal manu
How to configure a network device for connecting a notebook to the Console PortIf you use the Console port to manage CISCO devices, connect one end of the Console line to the Console port of the device, and the other end to the DB9 or DB25 interface of the computer.DB9 and DB25 interfaces are generally only available on the desktop. We cannot debug devices around the desktop every day. Instead, we often use
The RS232 interface is a standard for serial communication jointly developed by the American Association of Electronic Industry (EIA) and bell system, modulation regulator manufacturers and computer terminal manufacturers in 1970.
Its full name is "Technical Standard for Serial Binary data exchange interfaces between data terminal devices (DTE) and data communication devices (DCE)", which requires a 25-pin db25 connector, specify the signal content o
. RS-232 Serial Interface StandardAt present, RS-232 is one of the most widely used serial interfaces in PC and communication industry. A RS-232 is defined as a single-ended standard that increases communication distances in low-rate serial communication. The RS-232 adopts the unbalanced transmission mode, that is, the so-called single-ended communication.The data signal sent and received is relative to the signal location. For example, the data sent from the DTE device is 2-pin relative to 7-pi
Parallel Port
In 1284, the IEEE 1994 standard defined five parallel transmission modes:
1) compatibility mode
2) nibble Mode
3) byte mode
4) EPP enhanced parallel port Mode
5) ECP Extended Parallel Port
The hardware connector of the parallel port is db25, which is divided into three groups, such
1) Data lines (Data Bus) data lines2) control lines3) status linesThe data line is used to transmit data. The control line is used to control peripheral dev
addition, it can be used to connect to other terminals. When the router is connected to the modem through a cable, it must be connected using a AYSNC-to-DB25 or AYSNC-to-DB9 adapter. The connection between the router and the modem or terminal is shown in Figure 12.
The image of this topic is as follows:
Comprehensive Understanding of router interfaces and connections (4)
(2). Synchronous Serial Port
There are many synchronous serial port types supp
Currently, the commonly used serial ports include 9-pin serial ports (DB9) and 25-pin serial ports (DB25). When the communication distance is close (1. Description of common signal ports of DB9 and DB259-pin serial port (DB9) 25-pin serial port (DB25)PIN number Function Description1. Data Carrier Detection DCD 8. Data Carrier Detection DCD2 receive data RXD 3 receive data RXD3 send data TXD 2 send data TXD4
transceiver. The twisted pair jumper between the transceiver and the switch must also use a straight line. However, it is rare that a vswitch is a pure fiber interface.
2. connection between a router and an Internet access device
As we know above, the main application of routers is to connect to the Internet. This is the most widely used scenario when Internet access is made by local networks of public institutions, it is also an essential device. The connection between routers and Internet
, which is incompatible with the commonly used 24 V in industrial control. Therefore, the digital output needs to be connected to a drive module od25.
The connection between od25 and labjack u12 is mainly through a db25 line. It provides drivers for all the digital interfaces of labjack u12. The driving voltage can reach 50 V, the driving current can reach 500 mA, and multiple relays can be directly driven at the same time (if necessary ). Therefore,
terminal" phenomenon occurs. IEEE802.11 offers the following solutions. In the parameter configuration, if the Rts/cts protocol is used, and the maximum number of bytes is set at the same time----the Rts/cts handshake protocol is initiated once the data to be transmitted is greater than this upper limit: First, a sends an RTS signal to B, indicating that a sends some data to B, and B receives the RTS, A CTS signal to all base stations indicates that it is ready, a can be sent, the rest of the b
RS232 standard, using DB25 Connector, support synchronous and asynchronous serial port, The D-type interface can effectively prevent plug-in. Standardization has brought convenience to use.With the advent of the PC, these existing serial devices have undoubtedly become the original peripherals, and naturally the RS232 standard is adopted by the PC. But device manufacturers tend to have smaller, lower-cost interfaces, so the
video recorder RS-422 control protocol is different, Video Server Control Protocol is more, such as Louth, Odetis Protocol is open, proLINK is based on Profile.
Serial Interface Standard for RS-232 Protocol
At present, RS-232 is one of the most widely used serial interfaces in PC and communication industry. A RS-232 is defined as a single-ended standard that increases communication distances in low-rate serial communication. The RS-232 adopts the unbalanced transmission mode, that is, the so-ca
one of the most widely used serial interfaces in PC and communication industry. A RS-232 is defined as a single-ended standard that increases communication distances in low-rate serial communication. The RS-232 adopts the unbalanced transmission mode, that is, the so-called single-ended communication.
Figure 1 (see the figure below)
The data signal sent and received is relative to the signal location. For example, the data sent from the DTE device is 2-pin relative to 7-pin (Signal Locat
communication technology is also necessary, perhaps a reader who would like to use this technology to write a PDA and computer data sharing program.
This article mainly to RS232 to explain the Java serial communication technology.
RS232 Communication Basics
Rs-232-c (also known as EIA Rs-232-c, hereinafter referred to as RS232) is a standard for serial communications developed in 1970 by the United States Electronics Association (EIA) Joint Bell System, modem manufacturers and computer termi
connectivity Analyzer is primarily used to extend the connectivity of the Master Analyzer. And the length of the connecting cable can not exceed 15 meters. Both standalone and master parsers are connected to the database through 10BASE-T Ethernet and TCP/IP protocols.
Enterprise-Class Analyzer
Height is 1U and 6U two kinds
1U Height Analyzer can monitor 240 ports
The standard 6U Height Analyzer monitors 480 ports and can monitor up to 1920 ports by increasing the expansion card (6 expansion
The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion;
products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the
content of the page makes you feel confusing, please write us an email, we will handle the problem
within 5 days after receiving your email.
If you find any instances of plagiarism from the community, please send an email to:
info-contact@alibabacloud.com
and provide relevant evidence. A staff member will contact you within 5 working days.