This article introduces the dell server prompt Info: Memory module [DIMM] needs attention error solution. I hope this tutorial will help you.
The dell server hardware monitoring software openmanager can monitor the battery, motherboard, temperature, and hard disk. During monitoring, the following error message may be d
The site environment has two units of 06 annual output of the Dell R710 Server, RHEL5.4 operating system, an application server, an Oracle database server, hardware configuration, operating system, independent array card.A computer room power outage, air conditioning does not work, the engine room
Centos 7 mounts a raid 10 hard drive to the Dell R730 Server
The company purchased a new Dell R730 server with two SAS hard disks and four SATA hard disks respectively. SAS hard disks constitute RAID 1 and SATA constitute raid 10. Install Centos 7 on the server and set RAID
Virtualization of DELL server account opening and hyper-threading EnabledR410 R7101. Press the F11 button in the upper-right corner of the boot screen, and EnterBiosBootingManager will be displayed after you press it. In a short time, you will enter BIOS settings.2. Enter the BIOS option, select "SystemSetup", and press Enter.3. Select "ProcessSettings" and press Enter.4. Click the tab, select "Virtualizati
How to configure and install centos on the DELL R710 Server
At the time of writing this article, I just installed a DELLR710 system. Install the system on the server for the first time. The article will not describe the installation process in detail, there are many online. It only describes the problems I encountered.
In fact, the
Here are the steps to import a foreign hard drive into an array card, please do so when you are sure the data is backed up, and only provide references .Today, the Dell 720 system fails to boot up the monitor to see if there is a problem with the raid;1. Start the boot by pressing "ctrl+r" to enter the raid settings.2. enter PD Mgmt to view the status of the failed disk (foreign: foreign, Online: normal, missing: Disk not found, failed: failed)3. If t
Server: dell™poweredge™860
System: Windows 2003 R2
Problem: Install the 2003R2 version, the BIOS can identify 4G memory, after installing the system, can only recognize 256MB memory.
"How to solve the problem"
Enter BIOS as shown:
Setting the original OS Install Mode = "on" to "off" solves the problem that the
DELL
On the Dell R410 server, Debian 6 is issued by datahunter at, 28/11/2011 -.
Downstream PDF text
Update Time: 2/2/2012
Installing Debian on Dell R410 has a problem,
No Nic bnx2 driver (Broadcom NetXtremeII)
The reason is that it is non-free ....
There are two solutions:
1. The simplest
After the complete security of Debian, the lower-end firmware-bnx2.deb to n
◆ 1. For WINDOWS systems, password breaking software can be used to break the password, but it is different for LINUX systems. The following describes the specific operations:
1. After the server is restarted, press the key e to select the second item in the last three items, press the key e, enter linux single (single user mode), and press Enter.
2. Press the second key B and enter bash (clear password) and press Enter.
3. Enter passwd root and pr
1. Install the DEST tool on the local sideHttp://www.dell.com/support/article/cn/zh/cnbsd1/SLN287927_zh/zh?c=cns=bsdcs=cnbsd1l=zh2. connect idrac port ( Span style= "Font-family:simsun;" lang= "en-us" xml:lang= "en-US" >192.168.0.120 0 segment ip , interworking on the line. 3. The administrator runs the dest CLICommand : dellsysteminfo.exe-s 192.168.0.120-u root-p calvin-n root/dcim-d hw,st-r c:\logIdrac User name Root Password Calvin (password is the default password)4. You can a
.jpg "title=" Store 7.jpg "alt=" Wkiol1d_aiicykhcaadktvn3eug556.jpg "/>Ok! The expansion of the virtual host disk is complete. View the results. The disk space is getting bigger. The whole process of the original disk is a data storage. Directly after the online expansion. No data loss found. If the data is very important. Please back up beforehand.650) this.width=650; "src=" Http://s2.51cto.com/wyfs02/M00/83/E9/wKioL1d_aW6D_12KAAKIFUbljHw091.jpg "title=" Chunchu7.jpg "alt=" Wkiol1d_aw6d_12kaaki
if the value of await is much higher than the value of SVCTM, the I/O queue waits too long for the applications running on the system to become slower.- C parameterIostat can also be used to get CPU partial state values:Iostat-c 1 10avg-cpu:%user%nice%sys%iowait%idle1.98 0.00 0.35 11.45 86.22avg-cpu:%user%nice%sys%iowait%idle1.62 0.00 0.25 34.46 63.67Common usageIostat-d-K 1 #查看TPS和吞吐量信息 (disk read and write speed in KB) iostat-d-M 2 #查看TPS和吞吐量信息 (disk read and write speed in MB) iostat-d-x-k 1
Dell server operations
1. Raid problems:
# Deleting existing Raid configurations
MegaCli64-CfgLdDel-LALL-aALL
# Obtain the device ID and Slot Number
MegaCli64-PDList-aALL | egrep 'enclosure Device ID | Slot Number '| awk 'nr % 2 = 0 {print $3}; NR % 2! = 0 {print $4 ;}'
# Create Raid5, $ sdaslots is the disk ID and slot number used to create Raid that meet the parameter requirements. The size is 500 GB.
Meg
RAID1, and then looked at the instructions, the RAID card model is perc6/i, So he ran away with lunch at noon.
It took a little time to check it out at noon. There are 3 ways to solve the drive that loads raid:
1, load with floppy disk
2, use the software to write the drive into the U disk, U disk as a floppy disk.
3, using NLite to integrate the drive into the Server2003 installation disk.
1 on the pass, all the time, who has a floppy disk. Moreover the
A few days ago, the company purchased a new server, DELL R720. After installing and installing CentOS 5.6, it found that only lo exists and there is no eth * Nic, after several queries, rhel5.x or centos 5 was installed for newer machines such as r620 and r720. x system, without its NIC driver, so we need to install it ourselvesNIC Driver, http://zh-cn.broadcom.com/support/ethernet_nic/downloaddrivers.phpWe
, originally this may be related to the hard disk, that driver 0 is not the hard disk in the BIOS ID number? Is there a problem? The server uses a RAID5 array that has broken a hard drive and can continue to serve. (The server's hardware is compared to the old Powerage 850 's machine)
The next morning came to the office early, the Dell after the After-sale technical support, explained the situation, Dell's
Boot Disk download link: http://support1.ap.dell.com/cn/zh/forum/thread.asp? Fid = 15 tid = 261838
Note: using the dosa cd to boot and install the server system will cause all data on your server's hard disk to be lost. Therefore, this method is only for the installation of brand new servers and servers with the premise that data is backed upThis installation method only supports the retail version of the operating system and is integrated with SP2.
The unit's new Add 5 Blade service card, 3 M630 and 2 M820. My system is loaded with Windows 2008R2One of the M630 today temporarily said to connect the public network and to distribute the network IP, do a good network cable and external network connection, with the laptop input public IP after the test is normal, but even on the M630 network card even lights are not bright, it is called an egg pain.Toss for a long time to find out why:I just server
The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion;
products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the