Explain various raidRAID0:It's usually done with two plates.Write a file on two plates, respectively.This improves read and write speed.But it is not redundant and cannot be recovered by backup after data lossRAID1:It's done with two plates.That's what they call a mirror.Backup for each otherOnce a piece of data is lost, it can be recovered by another pieceRAID5:At least three plates requiredRAID5 is a compromise between RAID0 and RAID1.So it's 10/2=5.20170713l08-00 old boy Linux OPS training-
sure you want to initialize, press ENTER at OK to continue.Note: Initialization clears all information from the hard disk, array, and cannot be restored12, the confirmation can see the progress of the initialization, the left red box as a percentage, the right red box indicates the current operation. Waiting for initialization to proceed to 100%, the virtual disk configuration is complete.13, if you have just configured the virtual disk without using the full capacity of the array, the remainin
How to configure and install centos on the DELL R710 Server
At the time of writing this article, I just installed a DELLR710 system. Install the system on the server for the first time. The article will not describe the installation process in detail, there are many online. It only describes the problems I encountered.
In fact, the server is almost bigger, and the hardware self-check takes a long time. Ther
As a dual top configuration server, the Dell PowerEdge R710 adopts a 2U rack-mounted design style with excellent ventilation and heat dissipation, and features unique data security protection, it is specially designed for key nodes of large and medium-sized enterprises to meet the server requirements of enterprises.
Product features:
2U rack Server
Excellent ventilation and heat dissipation performance
. (generally used to reload the system or do not install the operating system to create a container (Adaptec array card)/logical drive (Ami/lsi array card).Use the Configuration tool software provided by the third party to implement the management of the card. such as Dell Array Manager. (These software is used on the server already has the operating system installed)Third, correctly identify the model of your array card (in this case,
If the total capacity of the hard disk is greater than 2T, the system cannot be installed in MBR format.Use GPT formatYou can't use Fdisk to partition it at this time.To use parted to partitionMore than 2t hard disk partition, the old boy video used to 5 pieces of 600G hard diskThere are several ways to install the systemI only remember two of them.Method One: Take 2 pieces of RAID 1 for the remaining 3 pieces to do RAID5Method Two: All made RAID5, th
The server is a R710 common error rollup:Error:E1422 CPU 1 Machine Check error. Power Cycle ACSolution:The system BIOS has reported a machine check error. Disconnect the system from AC power for 10 seconds, and then restart the systemAttached: DELL_LCD Error Prompt codeCode text ReasonE1000 Failsafe voltage error. Contact Support. (Fault protection voltage error.) Please contact your support staff. Review the system event logs for critical failure eve
The site environment has two units of 06 annual output of the Dell R710 Server, RHEL5.4 operating system, an application server, an Oracle database server, hardware configuration, operating system, independent array card.A computer room power outage, air conditioning does not work, the engine room server UPS power supply, because the temperature is too high shut down the machine, the database server shutdow
Label: for SP problems Linux BS server as installation
Many people have said that after the hard disk of the array is removed from the array, the location cannot be disrupted when the array information is re-imported from the hard disk. Two Dell r710 instances were used yesterday, perform experiments on four SAS 300g HP hard drives. The experiment steps are as follows:
1.
Dell PowerEdge Server RAID card driver downloadDell new Array Card driver download
Model
Support System Driver
h310/710/710p/810
Win2008 x32
Windows 2008 x64
Windows 2008 R2
Windows 2012
h700/h800
Win 2003 x32
Windows 2003 x64
Windows 2008 x32
Windows 2008 x64
Windows 2008 R2
H200
Win 2003 x32
Windows 2003
for system disks and LVM partitions for raid5 and raid0 when installing CentOS to facilitate dynamic resizing later.
Create a PV --> Create a VG (including the created PV). you can create a PV after installing the system, as shown in:
II. OMSA online RAID resizing
For OMSA installation instructions, see Dell PowerEdge R710 install OpenManage Server Administrator
. (generally used to reload the system or do not install the operating system to create a container (Adaptec array card)/logical drive (Ami/lsi array card).Use the Configuration tool software provided by the third party to implement the management of the card. such as Dell Array Manager. (These software is used on the server already has the operating system installed)Third, correctly identify the model of your array card (in this case,
Recently, my instructor asked me to configure a Samba server for the new Dell r900 server in the lab, sharing Linux and Linux Files on two PCs in the lab, and sharing Windows and Linux Files.
However, when installing the server system, I am a newbie and have not installed any servers. Follow the instructions in the instruction manual to install the boot disk. The first step is to click "Server Settings" on the main interface, why is an error prompte
Dell PERC 201710p import RAID card array information
Dell PERC 201710p import RAID card array information
1. Unplug the hard disks of one server (A) and insert them to another server (B) with the same configuration in the same order)
2. Start the server (B)
3. Press ctrl + R on the keyboard prompt To Go To The
Two days ago, a Dell r720 installed rh5.1 for business needs. Both the Dell official website and the utilty disc support rh5.8 or above.
The hard disk cannot be found at the partitioning step when the disc is installed. That is to say, the ramdisk of the initrd of the disc does not have the driver of the RAID card,
The procedure is described as follows:
This mach
A Dell nx3200 NAS storage (Dell r720) cannot enter the system when it is started, and the raid configuration cannot be detected on the raid card configuration page when you press F10 F2 F12 F11.
Fault prompt:There are offline ormissing virtual drives with preserved CachePlease check the cables and ensure that all dr
[Data recovery failure description]
A Dell PowerVault NF500, 3 300G SAS hard Drive composed of the RAID5 logical volume, the operating system for WSS 2003, two hard drive offline led to the entire NAS system is not working, Dell engineers forced the data after the failure to recover successfully.
The original logical volume is divided into C, d two areas, C for the system partition, you can reload, D is t
Centos 7 mounts a raid 10 hard drive to the Dell R730 Server
The company purchased a new Dell R730 server with two SAS hard disks and four SATA hard disks respectively. SAS hard disks constitute RAID 1 and SATA constitute raid 10. Install Centos 7 on the server and set
host service status for rebuild, starting from about 8 o'clock to 11 3 hours to complete the process.In fact, online reconstruction is allowed, but I always cautious. There is a saying: be careful to make the perpetual boat.If you take some time to recover your data business, you will get a colleague to say something. If you spend less time making the wrong data, you will get the boss to have tea.This article is from the "Anthony Big Group" blog, please be sure to keep this source http://52czy.
The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion;
products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the
content of the page makes you feel confusing, please write us an email, we will handle the problem
within 5 days after receiving your email.
If you find any instances of plagiarism from the community, please send an email to:
info-contact@alibabacloud.com
and provide relevant evidence. A staff member will contact you within 5 working days.