Intel released the Nehalem-EP processor successor Westmere-EP at us time in March 16 this year. The new-generation processor adopts a 32nm process. When the power consumption remains roughly the same, the number of cores of the processor is increased to six, and the number of cores is improved in all aspects.
Xeon 5600: Westmere-EP
Generally, Major server vendors will launch a series of products that use new processors and integrate other new technologies later this year. HP's new dual-channel
recently got an old server. HP DL380 G6 after installing esxi6.0 , found that the local hard disk will often fall off from time to time, and then have to restart the server, found the relevant information is due to the onboard p410i firmware version is too old to cause, And then prepare to update the firmware. Found several articles about using hpsum to update the firmware in the ESXi host, try this method because it works well for batch servers to up
Start the server, press F10 to start the HP Intelligent Provisioning, then select Perform Maintenance, then select HP Smart Storage Administrator (HP SSA) to open H The P SSA graphical interface is configured for RAID.1. If intelligent Provisioning is disabled, what to do, can be restarted, then press F9, then proceed to the next step in, that is, into the BIOS, and then put intelligent Provisioning This option is changed from disenabled to Enabled.2. After configuring the raid, reboot and insta
Solve the issue that CentOS 7 installation and startup of HP ProLiant DL380 G5 cannot recognize hard disks
1. Preface
The installation and startup of HP ProLiant DL380 G5 CentOS 7 cannot identify the hard disk. The author solved the installation problem by referring to the original article.
2. Practice
2.1 Identification of system installation Hard Disks
As shown in:
Select "Install Centos 7"
Press
Work needs, to deploy on the HP DL380 ge8 Server 2012, because the hand is only a USB flash drive, using the Windows USB DVD tool to write the system to the USB flash drive, set up the USB flash drive, you can directly enter the installation interface.Question 1. Windows cannot is installed to this diskThis is because the currently selected disk has an MBR partition table that can only be installed on a GPT disk on the EFI systemThe difference between
Recently, the company's management system is often unable to open, and the machine can not ping, check the discovery machine automatically shut down and the PPM lamp turns red, the server model is: HP DL380 G5Restart the machine after the normal start, but not a period of time after the failure to appear again, the PPM lamp red again!Consider the problem on the PPM, ppm is the "Processor Power Module Processor Power Modules" abbreviation, General Ente
BiosSP44873.exe (5.9 MB)http://h20000.www2.hp.com/bizsupport/TechSupport/SoftwareDescription.jsp?lang=encc=usprodTypeId= 15351prodseriesid=3884082prodnameid=3884083swenvoid=1005swlang=13mode=2taskid= 135switem=mtx-88b06606a93d42929136f411d7Reference Methodafter downloading the first unzip, and then you can see a few folders, respectively, different refresh mode required: There is disc refresh, floppy disk refresh, network refresh (ILO),usb key Refresh,USB floppy key Refreshes several ways. Refr
Solution:
Use Orca to configure RAID 5
The f8.
Press F8 to enter the array Configuration tool rbsu. Select the first item: create logical drive to go to the array creation page.
Use the Space key selection and Tab key
According to a report from the China IT lab on October 18, HP proliantdlw.g5 (470064-635) is a 2U rack-mounted server launched by HP. IT uses Intel's next-generation 45nm process processor IntelXeonDP54052.0G, the 2U chassis makes it suitable for hosting and ensures a spacious internal space, which is good for both heat dissipation and expansion.
According to a report from the China IT lab on October 18, HP ProLiant DL380 G5 (470064-635) is a 2U rack-
May 4-May 24, intermittent tossing and greenplum for three weeks, finally came to an end: the expansion, found that the expansion of capacity, had to upgrade; upgrade, found a bunch of errors, had to pause the repair database; fixed, continue to upgrade; Finally completed the expansion. This process is written in 8 blog post to the implementation process and problem solving are recorded, here to summarize the whole process. Originally had to write, but home outside a pile of things, dragged to t
Operations Case: HP server, Linux system extended/home partition with data protection
Department Requirements: The Research and Development Department proposes to expand disk space on existing servers to meet the disk requirements of the development environment. The existing space 1.6T needs to be increased to 2T.
Requirements Survey Analysis: 1, Hardware environment: Server HP dl380 GEN9, disk Configuration (600g*4), RAID5; th
I have the following errors in DMESG in my two servers, what is the reason for consulting?
os :rhel4.4 服务器型号: hp dl380 g4 ,g5 shpchp: acpi_shpchprm:\_SB_.PCI0 evaluate _BBN fail=0x5 shpchp: acpi_shpchprm:get_device PCI ROOT HID fail=0x5 shpchp: acpi_shpchprm:\_SB_.PCI0 evaluate _BBN fail=0x5 shpchp: acpi_shpchprm:get_device PCI ROOT HID fail=0x5 shpchp: acpi_shpchprm:\_SB_.PCI0 evaluate _BBN fail=0x5 shpchp: acpi_shpchprm:get_device PCI ROOT HID fail
Server 2008 Client Access License.
Starting with Windows Server 2008 R2, Microsoft has reduced support for the x86 platform while maintaining support for the X86-64 and Intel Itanium 2 processor platforms.
We tested the 2008 version of the Windows Server R2 x86-64 Datacenter version on a pair of HP servers (DL360 G6 and DL380 G6), which are used as hyper-V nodes in the failover cluster configuration. We also tested the R2 system running the domain
First, let's introduce the situation. server A and server B are both CentOS4.6 systems. now we need to create HACluster. to avoid split-brain attacks, we need to improve the reliability of the heartbeat link, which is the current connection situation, the eth2 and eth3 of server A are connected to eth2 and eth3 of server B respectively (no...
First, we will introduce the situation that both server A and server B are CentOS 4.6 Systems. now we need to build an HA Cluster. to avoid split-brain att
dl380 installing windows2008r2 times wrong, the installation package is the installation package that I have been using. I use CD-ROM, USB flash drive or ILO installation are reported the same error. Detailed errors are as follows:1. After copying the system, restart the installation times below error. When I click OK, the system restarts.Windows cannot read the 650) this.width=650; "Width=" 380 "height=" "src="/e/u261/themes/default/images/spacer.gif
file that contains multiple complex processes, including database queries, file cache reads, and template [compile] processing. Hardware environmentHardware: HP DL380 G5Hardware cpu:2x Intel Xeon E5420 (4 cores each, total of 8 cores)Hardware memory: 8GB of ECC RAMHardware disk: Smart Array p400i RAID-1 with 2x 147GB SAS drivesOperating system: Slackware 12.2 With almost all software compiled from sourceFile system: Ext3Apache version: 2.2.11, PHP ru
Installation of Oracle under a virtual machine:
(1) hardware environment
HP DL380 server CPU 3.0*2 memory: 4 GB hard disk: 100 GB
(2) software environment
Windows 2000 penetration Sion (using the same method as Windows XP 2003) Vmware gsx 3.0
(3) Installation
Vmware gsx 3.0 and a Windows 2000 Protocol sion operating system are provided in many documents.
(4) copy the installed system
Copy the system installed above and change the machine name and IP a
and compares the computing cost of the global (IP) method in both dynamic and static environments.(2) Measuring QoS of composite services Composite service has 20 or 80 tasks and one execution path, in static and dynamic environment.The result of the experiment is naturally that the global optimization method is better than the local optimization method.
Alrifai09, "combining global optimization with local selection for efficient QoS-aware service composition" Experiment settings
Hardware and
There's just an out-of-the-box HP DL380 G5, today trying to use this server to build an iSCSI storage space and connect to a vsphere host.System: Windows Server Storage Server,vsphere 5.0General installation system, add domain.I. Network-related configurationBecause Windows Server 2012 started to support multiple NIC bundles directly, no additional software tools were needed, so we bundled 2 ports to increase bandwidth and availability of iSCSI traffi
The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion;
products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the
content of the page makes you feel confusing, please write us an email, we will handle the problem
within 5 days after receiving your email.
If you find any instances of plagiarism from the community, please send an email to:
info-contact@alibabacloud.com
and provide relevant evidence. A staff member will contact you within 5 working days.