http://blog.csdn.net/u011981242/article/details/51059441Development environment: Vs2010+sql Server 2008Operating system: Win7_32bit flagship editionDevelopment language: C #Project name: Student Homestay Management SystemLet's start with: How do I package Windows applications?Open VS2010, open the project you want to package, then right-click on "Solution", "Add", "New project" and pop up the interface as shown:Click on the "Install and deploy" triangle to the left, select "Visual Studio Install
several questions on the use of Inno setupCategory: Install Setup 2013-02-02 15:48 1781 people read comments (0) favorite reports Inno Setup uses a few questions:
"Question one: Inno Setup executes the reg file code?" 】[Run]Filename: "{Win}\regedit.exe"; Parameters: "/s {tmp}\reg.reg" //Silent parameter/s
"Problem two: When installing, if you
computer, of course, you can also use the wireless search connection directly, but the novice is recommended to use a network cable directly connected.After the connection, open the browser, it is recommended to use IE, in the address bar input 192.168.1.1 into the wireless router settings interface.650) this.width=650; "border=" 0 "alt=" \ "src=" Http://www.xp510.com/uploadfile/2012-4/2012428172741336.jpg "style=" Border:none; "/>You need to log in to set additional parameters, the default log
there is no font directory at that time.{DAO} The DAO directory, when Setup runs on Windows 95/nt 4+, is equivalent to {Cf}\microsoft Shared\Dao, which is equivalent to {Win}\msapps\dao when running on Windows NT 3.51.Shell (shell) folder constants Inno Setup also supports a separate set of directory constants, which is the shell (shell) folder constants that are involved, and they have the same usage as o
Script sample analysis: Let's take a look at the [setup] section of the BASIC script created using the Inno Setup script Wizard: [setup]Appname = premiere 6.5 localized patch ----------------- (program name) appvername = premiere 6.5 localized patch ------------ (program name + version) apppublisher = Haizi studio ---------------------------- (developer or author
Install the Inno Setup Chapter1. Search Inno Setup2. Download Inno Setup3, choose to download the latest Innosetup-5.5.9-unicode.exe version (Innosetup-5.5.9.exe also support the Chinese Installation wizard)4. Install Inno Setup: Select the installation language (no Chinese option)5. Installation Inno Setup: consent Agreement6. Installation Inno
After compiling and compiling a program in VB and other languages, we often want to make a beautiful installation program to release our own software. We recommend using setup factory 7.0, which is a powerful Installation tool. This software provides the installation and production wizard interface, even if you do not know about installation and production, you can also generate professional installation programs. You can create shortcuts, add content
VarErrorcode:integer;Isrunning:integer;Determine if the client is running at installation function Initializesetup (): Boolean; Begin Result: =true; The Setup program continues Isrunning:=findwindowbywindowname (' E family client '); While isrunning Begin If Msgbox (' Setup detects that the client is running. ' #13 #13 ' You must close it first and then click Yes to continue the installation, or press No to
Today, small series in the online collection of some award BIOS setup tutorial, integration in addition to a more comprehensive, I believe that the general user can master the Basic Award BIOS setup method, in fact, award BIOS and AMI BIOS There are many things are the same, It can be said that basically the same, although some names are different, but the actual effect is the same.
The following is a deta
There is a huge competition in the current vro detailed setup and installation market. Some people may not know what the vro detailed setup and installation is. It doesn't matter. I have read the following parameters, you will also become an expert.
Dlink DI-524 router detailed setup Installation Process
Dlink DI-524 router detailed
Summarize:Simply put, because the flip-flop port to the gate has a delay, if the clock that paragraph delay is significantly larger, the setup may be negative, if the flip-flop port Gata that period of delay is significantly too large, hold may take a negative value. In my opinion, both of them are used to fine tune the same asynchronous problem when the data and clock pass through the filp-flop, so that the data and clock can not be changed so that t
1. Get the SQL Server installation pathVardbpath:string;Rtn:boolean;RTN: = Regquerystringvalue (HKEY_LOCAL_MACHINE, ' Softwaremicrosoftmssqlserversetup ', ' SQLPath ', dbpath);if (!RTN) then dbpath: = Expandconstant (' {app} ');2. Get the IP address of this machineip:string;Rtn:boolean;RTN: =regquerystringvalue (HKEY_LOCAL_MACHINE, ' systemcurrentcontrolsetservices{ 083565f8-18f0-4f92-8797-9ad701fcf1bf}parameterstcpip ', ' IpAddress ', IP);if (not RTN) or (ip= ' 0.0.0.0 ') or (ip= ") then IP: =
Script Example Analysis: First take a look at the [Setup] section of a basic script created with the Inno Setup Script Wizard:[Setup]appname=premiere 6.5 Chinese patch-----------------(program name) appvername=premiere 6.5 Chinese patch------------(program name + version) apppublisher= Studio----------------------------(development unit or author) apppublisherurl
http://379910987.blog.163.com/blog/static/3352379720110259414788/Some programs need to boot with the system, or need to establish some file associations, which are the result of operating the registry in the Setup program. The operation of the registry is implemented in Inno Setup through the [Registry] segment. Description of this paragraph:Parameter list:
Parameters
Description
For more detailed configuration, refer:
· Preparation-the Setup Manager wizard
· Preparation-the answer File
· Preparation-starting unattended setup Summary
This article describesHow to install the Windows 2000 Setup Manager wizard and use it to create an answer File. An answer File(The unattend.txt file)Is used to help automate Windows 2000 installations by prov
BUG: "setup was unable to create a DCOM User Account" error message in Visual Studio 6.0
*. Symptoms When you run the Visual Studio 6.0 setup program, you may receive the following error message: Setup was unable to create a DCOM User Account in order to register This first error message may be followed by a second message that indicates that
setup. How to make Inno setup package, I don't think I need to watch it here. A search a lot of ah, everyone is yard farming, each IQ high, no need to OH. Take a look at the help documentation and take care of the minute clock.Here's a talk about how to set up the Chinese Installation Wizard interface for Inno Setup.First, you download Inno Setup (for example, I
Python automated testing: setUp and tearDown instances, pythonteardown
This article describes how to use setUp and tearDown for python automated testing. The details are as follows:
The instance code is as follows:
class RomanNumeralConverter(object): def __init__(self): self.digit_map = {"M":1000, "D":500, "C":100, "L":50, "X":10, "V":5, "I":1} def convert_to_decimal(self, roman_numer
Use the Setup Factory installation package creation tool to create the installation package, setupfactory
After we develop the software, in addition to a few cases, we copy the entire directory to the customer, we generally need to make the installation package to facilitate the deployment of the entire software, to deploy an installation package, you may simply copy the file or perform additional operations such as the registry and database, however,
The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion;
products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the
content of the page makes you feel confusing, please write us an email, we will handle the problem
within 5 days after receiving your email.
If you find any instances of plagiarism from the community, please send an email to:
info-contact@alibabacloud.com
and provide relevant evidence. A staff member will contact you within 5 working days.