gbic 10gb

Read about gbic 10gb, The latest news, videos, and discussion topics about gbic 10gb from alibabacloud.com

What are gbic and Gbic Port cabling specifications

GBIC is the abbreviation of Giga Bitrate Interface Converter, is an interface device which converts gigabit electrical signals into light signal. The Gbic design can be used for hot-swappable. The gbic is an interchangeable product that conforms to international standards. Gigabit switches designed with GBIC interfaces

GBIC technical specifications and port wiring specifications

Technical Specifications for Gbic Specification size (high ' width ' length) 0.39 ' 1.18 ' 2.56 "(1 ' 3 ' 6.5 cm) connector multimode Fiber: SC single mode fiber: sc wavelength sx:850nm lx/lh:1300nm zx:1550nm Cabling Distance (max) sx:1804 ft (550 m) lx/lh:32810 ft. (10 km) zx:70 to 100 km Cabling Speci

Cabling Technology: Gigabit Optical GBIC and SFP specifications

1. What is GBIC? GBIC is short for Giga Bitrate Interface Converter. It is an Interface device that converts Gigabit electrical signals into optical signals. GBIC is designed for hot swapping. GBICIs an Interchangeable product that complies with international standards. The gigabit switches designed with GBIC interface

GB optical GBIC and SFP interface specifications

1. What is GBIC?? GBIC is short for Giga bitrate interface converter. It is an interface device that converts Gigabit electrical signals into optical signals. GBIC is designed for hot swapping. GBIC is an Interchangeable product that complies with international standards. The gigabit switches designed with

Technical Specifications of Gigabit Optical Fiber GBIC and SFP

1. What is GBIC? GBIC is short for Giga Bitrate Interface Converter. It is an Interface device that converts Gigabit electrical signals into optical signals. GBIC is designed for hot swapping. GBIC is an Interchangeable product that complies with international standards. The gigabit switches designed with

Quickoffice free and comes with 10GB space

Google has quickoffice the document editing software to iOS and Android devices, which cost 19.99 of dollars before users can use it to edit Microsoft Office documents. Get Quickoffice: Google play, IOS app Store. Google bought the Quickoffice in June 2012, and its purchase price was not officially disclosed. The software is well integrated into Google Drive and Google Docs, and so on. Except to make Quickoffice free, Google will also give Google Drive

The difference between Gbic and SFP

The SFP is the abbreviation for the small FORM pluggable and can be easily understood as an upgraded version of the Gbic. The SFP module is half the size of the Gbic module, and can be configured with more than one port number on the same panel. The other features of the SFP module are basic and gbic consistent. Some switch vendors call the SFP module a miniaturi

Cisco 3850 gbic Error handling

Today there are user Cisco 3850 Insert multimode Gigabit module after error log as follows:*oct 13:48:54:%platform_pm-6-module_errdisable:the inserted SFP MODULE with interface name GI1/0/18 was not suppor Ted*OCT 13:48:54:%pm-4-err_disable:gbic-invalid error detected on GI1/0/18, putting GI1/0/18 in err-disable state*oct 13:48:56:%LINK-3-UPDOWN:INTERFACEGIGABITETHERNET1/0/18, changed state-to-downCisco official website to view the document after processing as follows:3850 (config) # no errdisab

Recommend a few free PHP space/100G/10GB/1GB

Hongji host provides 10G free PHP space/100g traffic Hongji free Host network to provide the YH distributor, the full Chinese interface can be highly operational, speed is no problem. 10G space, 100G traffic, can be upgraded without hidden charges,

A few free php space/100G/10GB/1GB

Hongji host provides 10G free PHP space/100g traffic Hongji free Host network to provide the YH distributor, the full Chinese interface can be highly operational, speed is no problem. 10G space, 100G traffic, can be upgraded without hidden charges,

Binding domain name in Germany 10GB free php space _ free PHP space

Kilu.de free space from Germany, 10G capacity, unlimited monthly flow, FTP upload management files, support PHP5 (unsafe mode), provide 3 300M capacity of the MySQL database, more than 500 kinds of suffix of the free two class domain name for your

Basic knowledge of Ethernet switch stack and cascade (1)

When the number of ports that a single switch can provide is insufficient to meet the requirements of the network computer, more than two switches must provide the corresponding number of ports, which also involves the connection between switches. Basically, there are two ways to connect vswitches: Stack and cascade. 1. GBIC and SFP 1) GBIC Cisco GBICGigaStack Gigabit Interface Converter) is a common and lo

Ethernet switch stack effectively improves network performance

From the data, we can see that the bandwidth of the Ethernet switch stack is dozens of times the speed of the switch port, which can effectively improve the network performance, when the number of ports that a single switch can provide is insufficient to meet the requirements of the network computer, more than two switches must provide the corresponding number of ports, which also involves the connection between switches. Basically, there are two ways to connect a vswitch: Ethernet switch stack

Ethernet switch Stack

The maximum rate of Ethernet switch stack is faster, Which is multiple times faster than the port rate of the switch. Not all switches support Ethernet switch stack, when the number of ports that a single switch can provide is insufficient to meet the requirements of the network computer, more than two switches must provide the corresponding number of ports, which also involves the connection between switches. Basically, there are two ways to connect a vswitch: Ethernet switch stack and cascade.

Cisco Network device Naming conventions

-----Indicates that the TC represents the normal mouth is baset, there is no uplink mouth.-L LAN Base Image-S Standard Image-E Enhanced Image1u (1RU height)The SFP is an abbreviation for the Small Form-factor pluggable, which can be simply understood as the GBICUpgrade version. The SFP module is less than half the size of the Gbic module and can be configured on the same panel with multipleThe number of ports that are more than one times. Other functi

Network Technology Summary

are often recommended. 1000BASE-T requires four pairs of differential lines, In addition, compared with the 100BASE-TX standard, the requirements for transmission lines are much higher than those for the latter. If two Gigabit-speed devices are connected through four pairs of lines that do not meet CAT-5 Requirements, many frame verification errors and retransmission will occur. Terms: two thousand Mbps Ethernet port Converter GBIC Gigabi

Knowledge points of 50 routers required by network engineers

Gigabit stacked card GigaStack GBIC (WS-X3550-XL) (the card already contains CAB-GS- 50CM stacked cables) are required ). You can use either the chrysanthemum Link Method (providing 1g bandwidth) or the point-to-point method (providing 2G bandwidth ). C. Both methods can be used for backup. D. The Chrysanthemum Link Method supports stacking of up to 9 switches, and the point-to-point method supports up to 8 switches. 32. Does the Catalyst 3550 XL ser

Terminology required for learning networks

dedicated Gigabit stacked card gigastack GBIC (WS-X3550-XL) (the card already contains cab-gs- 50CM stacked cables) are required ).B. Two stack methods can be used: the chrysanthemum Link Method (providing 1g bandwidth) or the point-to-point method (providing 2G bandwidth ).C. Both methods can be used for backup.D. The Chrysanthemum Link Method supports stacking of up to 9 switches, and the point-to-point method supports up to 8 switches.2. is redund

Key Points of 44 vro knowledge

supports hot swapping of network modules, while Cisco3620/3640 does not support hot swapping of network modules. * The Cisco3660 redundant power supply is built in, while the Cisco3620/3640 redundant power supply is external.    24. Why 3640 cannot identify NM-1FE2W? Upgrade IOS to 12.0.7T Vswitch Problems About vswitches: 1. How is the stacking of Catalyst 35500XL/2950XL implemented? A. dedicated stacked cables, 1 m long or 50 cm long (CAB-GS-1M or CAB-GS- 50CM) and dedicated Gigabit st

Route Optimization Master Network engineer should master the 50 router knowledge points

built-in, while the cisco3620/3640 redundant power supply is external. 30, why 3640 does not recognize nm-1fe2w? Need to upgrade iOS to 12.0.7T About switch Issues: 31. How is the stack of Catalyst 35500XL/2950XL implemented? A. A dedicated stacking cable is required, 1 m long or 50 cm long (cab-gs-1m or cab-gs-50cm) and a dedicated gigabit stacking card Gigastack GBIC (WS-X3550-XL) with cab-gs-50cm stacking cable. . There are 2 stacking method

Total Pages: 15 1 2 3 4 5 .... 15 Go to: Go

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.