infiniband pcie

Read about infiniband pcie, The latest news, videos, and discussion topics about infiniband pcie from alibabacloud.com

NVMe over fabrics makes RDMA technology fire again.

What the hell is an RDMA? It is believed that most children who do not care about high-performance networks do not know much. But the advent of nvme over fabrics let the storage have to take time to look at this thing, this article will introduce the RDMA I know.RDMA (Remote Direct memory access) is intended to directly access the host's memory at the remote, without the need for host involvement . For example, when both the host and client are equipped with RDMA NICs, the data is transferred di

Disk iops Calculation and Measurement

). G. Skill Phoenix Pro et. al. ~ 20,000 iops SATA III SandForce-1200 based SSD Drives with enhanced firmware, States up to 50,000 iops, but real-world performance shows for all drives from different manufacturers ~ 25,000 iops for random read and ~ 15,000 iops for random write. Iodrive, a PCI-Express card with Flash 140,000 read iops, 135,000 write iops PCIe Iodrive duo 250,000 + iops

Devon's Linux kernel feature: 03 Driver "Go"

-wire bus for lightweight communications.IDE-These drivers are used to handle these pata/ide devices like CDROM and hard drives.Idle-This driver is used to manage the idle functionality of Intel processors.Iio-The industrial I/O core driver is used to process a digital-to-analog converter or A/D converter.InfiniBand-InfiniBand is a high-performance port for use in enterprise data centers and some supercomputers. The drivers in this directory are used

Ethernet (40g/100g) and basic cabling for next-generation data centers

has been launched, such as Mellanox Launched in September 2009 ConnectX-2 EN 40G PCIe network card, support IEEE Draft p802.3ba/d2.0 40GBASE-CR4,-SR and other protocols. Unlike the Mellanox monopoly InfiniBand chip, the IEEE 802.3BA chip competition will be more intense, the future price advantage of the product will be very obvious. 40G and 100G Ethernet in the end is what, to put it simply is to increas

NVME Related references

Dellpoweredge FC830 with Intel Broadwell Review mellanoxannounces Next Gen 100G InfiniBand Ethernet Smart interconnectadapter Mellanoxintroduces New BlueField Family of SoC Programmable processors Samsungbegins producing 512GB NVMe PCIe SSD microndebuts New 1100 2100 SSDs with 3D NAND Marvellintroduces New 88rc13xx Line of RAID Storage Controllers Emcexpands Its market leads in All-flash

Oracle Exadata Integration and cloud computing applications (i)

performance and availability. With Sun's industry-standard hardware and Oracle's intelligent database and storage software, the Exadata appliance delivers superior performance for all database load types, including online transaction processing (OLTP), Data warehousing (DW), and hybrid load consolidation. The Exadata all-in-one implementation is simple and fast, capable of handling the largest and most important database applications, and typically allows these applications to run up to 10 time

Java 7 SDP: Once written, running everywhere, sometimes also run super dazzle!

This article will briefly introduce the Java Socket Direct protocol (Sockets Direct PROTOCOL,SDP) introduced in the Java 7 SDK, and this new technology is a very exciting breakthrough. If you want to native access to InfiniBand's remote Direct memory access (Sqlremote direct Memory ACCESS,RDMA), SDP enables ultra-high performance computing (Ultra high Performance Computing, UHPC) Community uses Java-generic features and advantages in this uncommon scenario. RDMA provides a protocol for low laten

HPSuperdome: locate and change the NIC location

Description ========================================================== ==================================== Fc 0 0/0/4/0/0/0/0 fclp claimed interface hp AD299-60001 4 Gb PCIe 1-port fiber rechannel Adapter /Dev/fclp0 Fc 1 0/0/5/0/0/0/0 fclp claimed interface hp AD299-60001 4 Gb PCIe 1-port Fiber adapter /Dev/fclp1 Fc 2 3/0/4/0/0/0/0 fclp claimed interface hp AD299-60001 4 Gb

Some basic concepts of Oracle 11g RAC (2)

between different instances, but also can be used for heartbeat and regular communication. If the connection fails, the cluster is reorganized to avoid split-brain. Grid infrastructure restarts one or more nodes. You can configure a separate connection between RAC and grid infrastructure. In this case, you need to configure RAC to use the correct connection. This connection should always be private and should not be disturbed by other networks. RAC users can use two technologies to achieve inte

PC hardware knowledge required series-Main Board

vendors, such as AMD's a85x/a75 and Intel's z87/b75 are the chipset codes. It is mainly responsible for controlling non-video card slots such as sound card, Sata device, and I/O interface. It almost determines all functions of the motherboard and is the most important chip in the motherboard. There are a lot of old materials on the Internet, such as the "chipset" entry under Baidu encyclopedia. It also says [it is a general term of "nanqiao" and "beiqiao ], in fact, the North Bridge has been i

Configuration space of PCI and PCI-E devices in PowerPC

alignment. So pay attention to byte sequence conversion. When the powercp processor reads int_ack, the host converts the read operation into a PCI bus to interrupt the response transaction. It is the configuration space of 64 bytes that the PCI device must support. The value range is 0x00-0x3f: Many PCI devices only support 64-byte configuration space. The differences between PCI and PCIe configuration spaces are as follows: PCI/PCI-X and

Linux Device Tree in my eyes (four interruptions ),

it./{Model = "Marvell Armada 375 family SoC ";Compatible = "marvell, armada375 ";Soc {# Address-cells = # Size-cells = Interrupt-parent = Internal-regs {Compatible = "simple-bus ";# Address-cells = # Size-cells = Timer @ c600 {Compatible = "arm, cortex-a9-twd-timer ";Reg = Interrupts = Clocks = };Gic: interrupt-controller @ d000 {Compatible = "arm, cortex-a9-gic ";# Interrupt-cells = # Address-cells = Interrupt-controller;Reg = };}Pcie-controller {Co

Go FCoE completely subvert storage network architecture pattern Date: 2010-3-22

integration and synergy. Setting standards will enable administrators to trust FCoE and CEE on virtualization and blade servers on the periphery of the data center, and to be able to trust their capabilities in the datacenter core environment. Although the standard has not yet been formally established, but has attracted enough manufacturers and enterprises to bring commercial products to the adopters, is expected 2010 FCoE and CEE will become mainstream products. In addition, most of the stora

Examples of CLOS architectures network-level device-level Fattree network-level Clos and Clos-related scheduling algorithm RR

, because in each case you could immediately imagine or construct a theoretical test method to prove it.2. FAT Tree Network and network level ClosTo say the fat tree concept, you can start with the architecture of the infiniband[Note 1] switch. The InfiniBand switch is prone to 288 ports (port rate 10g/20g/40g), and its chip is a fat tree to build a high-density port switch. Note The 1:

Distributed File System Glusterfs installation steps

1------------192.168.2.55 the directory in which the configuration file is located is/etc/glusterfs/ [Root@redhat1 glusterfs]# more Protocol-server.vol ### Export volume ' brick ' with the contents '/home/export ' Directo Ry. Volume brick type storage/posix # POSIX FS translator option Directory/data/movies # EXP Ort this directory End-volume ### ADD network serving capability to above. Volume server type protocol/server option transport-type TCP # for TCP/IP transport option Transport.socket

Introduction to VF and NF functions

VF: virtual functionPF: Physical functionSR-Iov:Introduction to SR-IovSR-Iov Technology is a hardware-based virtualization solution that improves performance and scalability. The SR-Iov standard allows efficient sharing of PCIe (peripheral Component Interconnect Express, fast Peripheral Component Interconnect) devices between virtual machines, and it is implemented in hardware to achieve I/O performance comparable to native performance. The SR-Iov spe

Huawei MiB parsing and translation

powerPeakpoweroccurtime Peak power generation timeAveragepower Historical Average PowerPowerconsumption Cumulative Power consumptionPowerstatisticstarttime Power Statistics Start timeClearpowerstatistic Clearing Power statisticsPower ManagementPowercappingenable Power capping enabled statePowercappingvalue Power Capping ValuePowercappingfailureaction Power capping failure further actionPCIe Device PropertiesPciedeviceentirestatus PCIe Overall health

PCI Hot-swappable __ Embedded

PCI Express Hot plug, the firmware must provide either a oshp method or one of the ACPI _OSC methods; The software element refers to the functional components that must be provided by the operating system for the integrated use of PCI Express Hot plug. software Elements In order to manipulate the hardware elements of the platform and provide PCI Express hot-swappable services, we must implement the main hot-swappable software elements shown in table 1. PCI Express Service Model Standard hot-swa

Multi-port server Nic solution in Bypass Mode

PCI Express, with four-port gigabit connections providing higher network bandwidth Using a four-port Gigabit server Nic on any server, especially on Intrusion Prevention servers, can demonstrate significant advantages. The four-port PCI Express (PCIe) server Nic can provide four network connections from a single server slot, so that other server slots can be retained for more applications. Multiple Gigabit ports can increase network bandwidth through

DELL R710 Error code Rollup

Battery. (RAID controller battery failure.) Please check the battery. The RAID battery is lost, damaged, or unable to recharge due to temperature problems.E1216 3.3V regulator failure. Reseat PCIe cards. (3.3V regulator failure.) Please reset the PCIe card. ) The 3.3V voltage regulator is faulted.E1229 CPU # VCORE regulator failure. Reseat CPU. (CPU # VCORE voltage regulator failure. Please reset the CPU.

Total Pages: 15 1 .... 3 4 5 6 7 .... 15 Go to: Go

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.