informatica installation

Discover informatica installation, include the articles, news, trends, analysis and practical advice about informatica installation on alibabacloud.com

Informatica Common Components Lookup cache two use the persistent lookup cache

fail. Rebuild the cache. Edit mappings (except for lookup conversions). Re-use the cache. Rebuild the cache. Change the database connection or the file location used to access the lookup table. Causes the session to fail. Rebuild the cache. Change the PowerCenter Server data movement mode. Causes the session to fail. Rebuild the cache. Change the order of arrangement in Unicode mode. Causes the sessi

Overview of the Informatica Common components filter

passes the transformation, depending on whether the row meets the specified criteria. Only rows that return TRUE can pass this conversion. The discarded rows do not appear in the session log or in the Reject file.For session performance optimization, you should make the filter transform as close to the source in the map as possible. Instead of passing the rows you are about to discard to the map, you filter out unwanted data from the source-to-destination data stream later.You cannot connect mu

Informatica Common Components Source Qualifier Distinct

. customer_id, ORDERS. Sales_tax_rate, ORDERS. store_id fromWHERE CUSTOMERS. customer_id=ORDERS. customer_idSelect DistinctHowever, if you modify the default query after selecting Select different, PowerCenter will only use the query defined in the SQL query properties. That is, the SQL query overrides the select dissimilar setting.To use Select dissimilar: Open the Source qualifier transformation in the map, and then click the Properties tab. Select Sel

Informatica Common components lookup two connected and disconnected lookups

Connected Lookup transformation receives input values directly from other transformations in the pipeline. For each input row, PowerCenter queries the lookup source or cache based on the lookup port and criteria in the transformation. If the conversion is not cached or the static cache is used, PowerCenter Server returns the value of the lookup query. If the transformation uses dynamic caching, PowerCenter Server inserts the row into the cache when no rows are

[Informatica] converts data formats using normalizer

In Informatica development, we can use the normalizer component to convert the data format. First, we will introduce some property parameters of the normalizer component. Attribute Description Column name Name of the source column. Level Group Columns. columns in the same group occur beneath a column with a lower level number. When each column is the same level, the transformation contains no column groups.

Bulk export of the shell script for Informatica Object

#!/bin/bash #-----------------------------------------------------------------------# Script name:inf_impobj.sh# purpose:to batch export mappings or workflows to XML files # Created by:indifferent_to# date:2014-11-26 #------------- ---------------------------------------------------------function Usage {cat Bulk export of the shell script for Informatica Object

Informatica Common components source qualifier before and after the session SQL

semicolon (;) Separate multiple statements. PowerCenter Use the/* ... */comment. If you need to use semicolons outside of quotation marks or notes, you can avoid this by using a backslash (\). If the semicolon is escaped, PowerCenter ignores the backslash and does not use a semicolon as the statement delimiter. The Designer does not validate SQL. Note: You can also enter pre-and post-session SQL commands on the Properties tab of the target i

Informatica Common Components Source qualifier SQL Query

the variable. 5. Select the ODBC data source that contains the sources included in the query. 6. Enter the user name and password to connect to this database. 7. Click "Validate". Designer runs the query and reports that the syntax is correct. 8. Click OK to return to the Edit Transform dialog box. Click OK again to return to the Designer. 9. Select "Database-save". Tip: You can adjust the size of the expression editor. Drag the border of the dialog box to enlarge it.Designer Saves the new dime

Why are the double quotation marks at the beginning and end when Informatica writes a parameter file ""

When you use mpping in infa811 to generate a parameter file, the generated TXT text will be opened and double quotation marks at the end, as shown below: "[Global] $ Flight_date = 20090105 $ St_date = '2017-01-05' $ End_date = '2017-01-05' "  

Informatica Common Components lookup seven find criteria

PowerCenter uses the find criteria to test the received values. This is similar to the WHERE clause in the SQL query. When you configure a lookup condition for a transformation, the values in the transform input values and the lookup source or cache

Informatica Common Component Source qualifier User Defined Join

User defined join:Entering a user-defined join is similar to entering a custom SQL query. However, you only need to enter the contents of the WHERE clause instead of the entire query.When you add a user-defined join, the Source qualifier

Informatica Common Components lookup three relationship and flat file lookup

When you create a Lookup transformation, you can choose to use a relational table or flat file as the lookup source.Relationship LookupWhen you use a relational table as a lookup source to create a Lookup transformation, you can use ODBC to connect

Informatica extracting SQL Server database garbled

1, first confirm the database relationship between the use of the code page, is consistent2, if the above method does not work, change the data type in the designer, the string type to nstring type, Chinese is not garbled3. The type of text in the

Informatica Common components aggregator two-packet-based ports

The aggregation transformation allows you to define groups for aggregations, rather than performing aggregations across all input data. For example, instead of looking for total company sales, you can find the total sales by region group.To define a

Informatica Common Component Source qualifier join query

Join source dataYou can use a Source qualifier transformation to join data from multiple relational tables. These tables must be accessible from the same instance or database server.When mapping uses related relational sources, you can join two

INFORMATICA's meta Data Management II: Running status information query

The project of two buddies to do about the running status metadata of the two job is cool, the recent period of good health, their reference to learn at the same time to do log records, hehe, in order to save ink, related metadata table structure

Informatica Common components aggregator three using sort inputs

You can use the Sort input option to improve aggregate conversion performance. When you use sort input, PowerCenter assumes that all data is sorted by group. When PowerCenter reads a set of rows, it performs an aggregation calculation. When needed,

Bi_dba_ installation (4): Installing the DAC and configuring the client

Label:1. Preparation The informatic Client must be installed before installing the DAC; dac11g client must be installed on a single machine with the Informatica client; Install Java version 1.6 and above on dac11g server; dac11g server must be installed on a single machine with Informatica server; when the installation is complete, the DAC directory contains the

Lamp Environment Deployment: Apache Source installation +mysql binary installation +php source installation +nginx Source installation

Tags: yum source thread ima mysql parameter std DSO status config useApache version: 2.2.27MySQL version: 5.5.54-linux2.6-x86_64PHP version: 5.3.27First, source code installation Apache1. First install the Upload tool2, upload the lamp environment required installation package3. Unzip all installation packages4. Install Apache Dependency Package5. Create the

The installation of vc000000006.0. prompt that the installation error of acmboot.exe cannot be sent (the installation can be solved after the installation of the XP Virtual Machine encounters a practice)

[-] Previously, vs6 has never encountered any problems. During the recent installation, there was always an acmbootexe sending error. It is estimated that some compatibility problems were caused by my XP system version. Google found the solution Copy vs98entstf under setup in the installation directory and name it acmsetupstf. Copy all files in setup to the install

Total Pages: 15 1 2 3 4 5 6 .... 15 Go to: Go

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.