InstallShield Program Packaging diagramThe packaging tool in VS2012 is considered an assembly, and is created under the program solution as it is used with the assembly. What we need to do is add the item. But for first-time friends, we need to download and install the packaging tool as prompted. Specific installation methods are no longer detailed, many online information.1. Set the installation assemblyAfter the
InstallShield only InstallScript works, the installation package is compressed into a Setup.exe in case you can modify the icon. How to do this is in the release view, select your release entry, and then select the Setup.exe tab, set in the single Exe Icon fileInstallShield Basic MSIA Engineering Setup Method:1. Open the installation:C:\Program Files\installshield\2010\redist\language independent\i3862. Usi
This document describes how to useInstallShieldInstall and uninstall the database, andInstallShield 11.5 premier EditionAndInstallShield 12 premier EditionEnvironment. (AboutInstallShieldSuch a well-known InstallationProgramI will not introduce the production tools much.)
(InInstallShieldPackage in. NET FrameworkSee about Using InstallShield to deploy. NET Framework) Zhang Lei. Live
1. Open "SQL scripts View", 1
Figure 1. Open the SQL Script Vie
The installation package of Pb software is the registry and database, which has been used in the past. The Registry and database must be manually written to the script, which is annoying and often causes errors, because is does not track external programs called, there is no fault tolerance during errors, no error is reported, and the customer cannot generate a database, that is, it cannot. I don't know why it doesn't work.
This is how to generate a database during
Create an InstallShield installer for the installscript script, update the environment variables in the script code, and then find that the Registry and computer-> properties-> advanced-> the variable values in the environment variables are updated, however, the environment variables cannot be obtained from the command line (WIN + R, CMD.
This problem occurs because no update notification event is sent to the Windows system when the environment variab
////////////////////////////////////////////////////////////////////////////////
//
IIIIIII ssssss
II SS InstallShield (R)
II ssssss (c) 1996-1999, InstallShield Software Corporation
II SS (c) 1990-1996, InstallShield Corporation
IIIIIII ssssss all Rights Reserved.
//
//
This code is generated as a starting Setup template. You should
Modify it to provide all nece
recently in the study using Instanllshield to make the installation package, and to create data, to master the InstallShield in the launchappandwait functionThis function is the effect of running other programs at run time, and can pass parameters and whether to run silently. For example:szscriptpath =supportdir+ "\\CREATEORACLEUSER. SQL ";longpathtoquote (Szscriptpath, TRUE);szCmdLine = DBUSER + "/" + Dbpass + "@" + DBNAME + "@" + Szscriptpath; nresu
Brief Introduction
InstallShield has built-in support for MySQL and Oracle. However, this function is implemented through ODBC and has strict requirements on the SQL script format. Therefore, an error is often reported when the script that has been tested on the official client is executed in is.
Generally, database scripts can only be tested through the official client. It is time and effort-consuming to maintain a script for is execution. Therefore,
Original post address: http://www.delphibbs.com/delphibbs/dispq.asp? Lid = 1048756
Our company's software is packaged together with sqlserver and has a protocol with Microsoft.
I wrote
Program To control the installation of sqlserver7. After trying for a year, it can basically be installed, no major problems
In fact, it is done by referring to the installation instructions of online help.
The following is a typical unattended installation script. During installation, the SQL installer is notifi
In the following example, InstallShield can use Winsock to obtain the IP address and save the following files as tcpip. rul
# Define wsadescription_len 256
# Define wsasys_status_len 128
Typedef
Wsadata
Begin
Int wversion;
Int whighversion;
Char szdescription [wsadescription_len + 1];
Char szsystemstatus [wsasys_status_len + 1];
Short imaxsockets;
Short imaxudpdg;
Pointer lpvendorinfo;
End;
Wsadata structwsadata;
Wsadata pointer pwsadata;
Typedef host
Previous Article: solved the problem of residual target folders during uninstallation.
In installation designer --> organization --> features, select the feature to be set. In the attribute column on the right, select "yes" for required. During installation, the feature is selected, the check box is gray and the status cannot be changed. That is, the feature cannot be selected and will be installed on the target machine.
Next article: InstallShield
Original article: InstallShield script file copy FAQsMany friends often ask: why is it invalid for me to copy files using the copyfile/xcopyfile function?There are many reasons for this situation. I have summarized it a little today. You are welcome to follow this article to find some incomplete information.1: The file path is incorrect. For example, the copyfile/xcopyfile script is put in onfirstuibefore, but the Referenced File Path is installdir/ta
Original article: InstallShield refresh the system at the end of InstallationAdd code in onend, two solutionsKevin's Solution# Include "ifx. H"// Call to Windows used in the "onend" function to refresh the DesktopPrototype shell32.shchangenotify (long, long, pointer, pointer );// -- Add the following to the "onend" Function// Refresh the desktop to display icons (or remove if uninstall)Shchangenovel (134217728, 0, null, null );Solutions for group frie
Http://www.cnblogs.com/installshield/archive/2010/12/23/1914595.html Author: Kevin Wan
Below is a sampleCodeAssume that the MSI file is stored in support files and the third-party MSI package is called through Silent Installation. You can enter msiexec to view the parameters of msiexec.
Function callthirdmsipackage ()String svmsiexec, svparam, svmsipackage;BeginSvmsiexec = winsysdir ^ "msiexec.exe ";Svmsipackage = supportdir ^ "***. MSI ";Svpar
Problem Description: you need to enter a string of characters at the time of installation to call C # encapsulated DLL for processing. Calling the DLL method with InstallScript has failed, prompting an error such as.Tools: InstallShield 2015Visual Studio 2017Solution:C # code sectionTestClass.cs, define three methods. The namespace is libtest and the class name is TestClass.AssemblyInfo.cs, set ComVisible to true;Put the generated LibTest.dll into the
This tool is called "InstallShield", you can go to the next online, there is a green version of the installation version.
1, a new project, those companies and software basic information just fill in the line.
2, choose the format, here we choose the first one. Language Select Simplified Chinese
3. Select program Folder
4. Set executable file
(1) Here can be set according to their own preferences, in order to facilitate my ch
installshield| program///////////////////////////////////////////////////////////////////////////////
//
Function:onmaintuiafter
//
Event:maintuiafter event is sent after file transfer, as end user runs
Installation that has already been installed on the machine. Usually
This happens through Add/remove Programs applet.
In the handler installation usually displays UI that would inform
End user that Maintenance/uninstallation has been completed successf
installshield| program///////////////////////////////////////////////////////////////////////////////
//
Function:onmaintuiafter
//
Event:maintuiafter event is sent after file transfer, as end user runs
Installation that has already been installed on the machine. Usually
This happens through Add/remove Programs applet.
In the handler installation usually displays UI that would inform
End user that Maintenance/uninstallation has been completed successf
The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion;
products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the
content of the page makes you feel confusing, please write us an email, we will handle the problem
within 5 days after receiving your email.
If you find any instances of plagiarism from the community, please send an email to:
info-contact@alibabacloud.com
and provide relevant evidence. A staff member will contact you within 5 working days.