address-u root-P password power on/reset/off
Power on hard bootPower ResetPower off hard shutdown
For example, the IP address of your server is 192.168.162.14, And the password set at that time is donglirong. Now the server is in the starting state, if you want to remotely restart the server (equivalent to pressing the restart button on the server by hand), use the following command
Ipmish.exe-IP 192.168.162.14-u root-P donglirong Power Reset
If no other prompt is displayed after the preceding
In today's large network of enterprises, network security has always been a concern of managers, virus transmission and hacker intrusion has become the main threat of foreign attacks on corporate networks. At present only the virus or hacker's single means attacks the network to attack the phenomenon to be less and more, but is more uses many kinds of attack means the synthesis use. At present, the most prominent is the transmission characteristics of the virus and hacker attack characteristics
This article describes the use of Ipmitool tools, this command is mainly used to operate the server hardware, so the general business operations are rarely used, but it is very powerful, such as: can be hard to restart the server, reset the BMC port, configure BMC Port IP, into the GRUB environment, set the boot sequence, and so on.
It will be installed by default in most versions of CentOS and Redhat Linux, so it is more practical.
Another benefit
IPMI is an extensible standard that defines how to monitor hardware and sensors, control system components, and record critical events as IPMI technology is used in servers, leveraging the many advantages of IPMI as an integral part of server management, especially in cluster management. This paper first introduces some basic concepts of IPMI, and then gives the steps and methods to implement IPMI management in Linux system by using Ipmitool tool. 1.
Ipmitool Chinese help document
Name)Ipmitool -- Effective for devices that support IPMI.
Synopsis (Summary)Ipmitool [-c |-H |-v]-I openIpmitool [-c |-H |-v]-I Lan-H[-P][-U][-A][-L][-A |-E |-p |-F][-O]Ipmitool [-c |-H |-v]-I lanplus-H[-P][-U][-L][-A |-E |-p |-F][-O][-C]Description)This program enables you to use IPMI v1
1. Introduction
IPMI (Intelligent platform management interface) is a new generation of common interface standards that enable intelligent Hardware Management. You can use IPMI to monitor the physical characteristics of the server, such as temperature, voltage, fan operating status, power supply, and chassis intrusion. The biggest advantage of IPMI is that it is independent of the CPU bios and OS. Therefore, you can monitor the server as long as the power is switched on or off. IPMI is a standar
This article describes the use of the Ipmitool tool, this command is mainly used to operate the server hardware, so the general business operations will rarely use it, but it is very powerful, such as: the ability to restart the server, reset the BMC port, configure the BMC Port IP, into the GRUB environment, set the boot sequence, and so on.It is installed by default in most versions of CentOS and Redhat, so it is more useful.Another advantage is tha
1. Download ipmitool:http://ipmitool.sourceforge.net/2. Make sure the GCC tools are installed3. Load the IPMI-enabled driver on the Linux system:Insmod/lib/modules/2.6.32-220.el6.x86_64/kernel/drivers/char/ipmi/ipmi_msghandler.koInsmod/lib/modules/2.6.32-220.el6.x86_64/kernel/drivers/char/ipmi/ipmi_devintf.koInsmod/lib/modules/2.6.32-220.el6.x86_64/kernel/drivers/char/ipmi/ipmi_si.ko4. Check your/dev directory for ipmi0 this device:Ls-l/dev/ipmi*5. Unzip the
information, the display of system log content, and network remote switching machines. There are two ways to use Ipmitool (table 1)Table 1Back to top of page2. Prerequisites for using IPMITo achieve IPMI management of the server, you must meet the following aspects: hardware, OS, management tools, etc.2.1 The server hardware itself provides support for IPMICurrently, most vendors such as HP, Dell, and NEC support IPMI 1.5, but not all servers are sup
remote switching machines. There are two ways to use Ipmitool (table 1)Table 1Back to top of page2. Prerequisites for using IPMITo achieve IPMI management of the server, you must meet the following aspects: hardware, OS, management tools, etc.2.1 The server hardware itself provides support for IPMICurrently, most vendors such as HP, Dell, and NEC support IPMI 1.5, but not all servers are supported, so you should first determine whether the server sup
, sdr,sensor information view1. View the SDR sensor information:Ipmitool-h (BMC management IP address)-I lanplus-u (BMC login user name)-p (password for BMC login username) SDR2. View sensor information:Ipmitool-h (BMC management IP address)-I lanplus-u (BMC login user name)-p (password for BMC login username) sensor listVIII. MC (Management Unit BMC) status and control1. Restart the BMC:Ipmitool-h (BMC management IP address)-I lanplus-u (BMC login user name)-p (password for BMC login username)
./Configure-enable-INTF-open = static
Insufficient Permissions
Chmod 755 configure authorization
./Configure-enable-INTF-open = static
Make
Make install
[Root @ localhost ipmitool-1.8.10] # ipmitool-I open sensor get "processor 1 Temp"Locating sensor record...Cocould not open device at/dev/ipmi0 or/dev/IPMI/0 or/dev/ipmidev/0: no such file or directoryGet device id command failedUnable to open SDR f
Remote KVM Switching machine:Ipmitool-h IP address-i lan-u KVM user-P KVM password power off #关机Ipmitool-h IP address-i lan-u KVM user-P KVM password power on #开机Ipmitool-h IP address-i lan-u KVM user-P KVM password Power reset #重启Ipmitool-h IP address-i lan-u KVM user-P KVM password MC reset #重启BMCTo create an IPMI account and add permissions:Ipmitool-h IP addre
One, the GPU server#配置两个主板集成千兆四个外插PCI万兆网卡 #The onboard network card can be obtained using the command: RAW 0X30 0X21 can read to the first NIC of the Mac, is the following return value of the next 6 bits. 0c,c4,7a,55,4d,6c.0x30 0x9F = Yellow circle indicates how many LAN Macs are behind the first LAN, and the red box is a second LAN MacGet the first motherboard integrated gigabit NICIpmitool-i lanplus-h 10.28.115.11-u admin-p ADMIN Raw 0x30 0x21Get other motherboard integrated Gigabit NICsIpmito
In the past two days, a bunch of large clusters with 500 nodes have been configured, which has been plagued by the IPMI problem for a day and a half. At pm, the problem was finally solved. Here is a summary:
The intelligent platform management interface (IPMI) is an industrial standard used to manage peripheral devices in an Intel-based enterprise-level system, you can use IPMI to monitor the physical health characteristics of servers, such as temperature, voltage, fan operating status, and Pow
1. IPMI (Intelligent platform management interface ):That is, the smart platform management interface is a new generation of common interface standards that make Hardware Management "intelligent. You can use IPMI to monitor the physical characteristics of the server, such as temperature, voltage, fan operating status, power supply, and chassis intrusion. The biggest advantage of IPMI is that it is independent of the CPU bios and OS. Therefore, you can monitor the server as long as the power is s
Http://blog.csdn.net/yunsongice/article/details/5408802
The intelligent platform management interface (IPMI) is an industrial standard used to manage peripheral devices in an Intel-based enterprise-level system, you can use IPMI to monitor the physical health characteristics of servers, such as temperature, voltage, fan operating status, and Power status. The standards are customized by companies such as Intel, Hewlett-Packard (Hewlett-Packard), NEC, Dell, and
Background information:IPMI, an acronym for the Intelligent Platform Management interface (Intelligent Platform Management Interface), is an industry standard used in managing peripherals used in intel-based enterprise systems, which is based on Intel, Hp,dell and Supermicro and other companies developed. Users can use IPMI to monitor the physical health characteristics of the server, such as temperature, voltage, fan status, power status, and so on.
key points.
Cobbler already has the web ui. However, a lot of things are not tied to the work orders and Data Platform interfaces on your own side, so you just do it yourself.
You must be extremely careful when installing an automatic installation. Do not install it on your online machine. To ensure this, competent companies generally configure a vlan, where pxe is located, in this vlan, pxe can only communicate with pxe servers and servers of the same level. Pxe has two NICs, one being pxe a
The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion;
products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the
content of the page makes you feel confusing, please write us an email, we will handle the problem
within 5 days after receiving your email.
If you find any instances of plagiarism from the community, please send an email to:
info-contact@alibabacloud.com
and provide relevant evidence. A staff member will contact you within 5 working days.