Linux Server Setup--ISCSI

---service-side---1. Preparing the diskAdd a disk SDD to another virtual machine2. Install the target packageperl-config-general-2.40-1.noarch.rpmscsi-target-utils-0.0-5.20080917snap.ky3.x86_64.rpm3. Modify the configuration file, set the storage disk/etc/tgt/targets.confSet/DEV/SDB to Ip-san's network storage disk.IQN:ISCSI qualified name (ISCSI qualified name)iqn.yyyy-mm.# TGTD Example targets file## Example ISC

How to setup ISCSI target using Tgtadm

1.Start the TGTD service#service TGTD StartThe TGTD service is provided by the package:scsi-target-utils.x86_642.Define an ISCSI target name: (for example)# Tgtadm--lld iSCSI--op new--mode target--tid=1--targetname iqn.2001-04.com.example:storage.disk1.amiens.sys1.xyz3.To View the Currect configuration:# Tgtadm--lld iSCSI--op show--mode TargetFor example, we are

Rh436-configure the iscsi shared disk name and permissions through udev (rhel5.5)

Configure the iscsi shared disk name through udev: [root @ localhost ~] # Udevinfo-qpath-n/dev/sdb/block/sdb [root @ localhost ~] #/Sbin/scsi_id-g-s/block/sdb1IET00020001 [root @ localhost ~] # Vim/etc/ud Configure the iscsi shared disk name through udev: [Root @ localhost ~] # Udevinfo-q path-n/dev/sdb/Block/sdb[Root @ localhost ~] #/Sbin/scsi_id-g-s/block/sdb1IET 00020001[Root @ localhost ~] # Vim/etc/ude

Mount iSCSI network storage in CentOS 6.4

Mount iSCSI configuration on CentOS 6.4 1. Install the iscsi support package and start the service.Yuminstall binutils iscsi-initiator-utils kmod-xfs xfsprogs Service iscsi start2. log on to Network StorageIscsiadm-m discovery -- type sendtargets -- portal 192.168.1.100 (storage address)Results: 192.168.1.100: 3260,1 i

iSCSI Workflow Target and initiator

With the exponential growth of enterprise-class data, the traditional centralized storage scheme cannot meet its storage requirements, so the storage area network (storage region Network,san) technology is widely used, but its existence is short, the price is expensive and the construction is complex. IP storage technology based on iSCSI protocol is an emerging network storage technology, which integrates IP network technology into storage I/O, and ha

Attaching NBD and iSCSI in Ubuntu

: The NBD device is used as the swap space. NBD-client-D nbd_device is used to disconnect After the connection is successful, you can view the NBD-client process. # Ps-Ef | grep NBD Root3156 1 0 00:00:00 pts/0 NBD-client 192.168.1.1 1234/dev/nbd0 You need to format the device before use. # Mkfs. ext3/dev/nbd0 Mount this block device. # Mkdir/mnt/nbd0 # Mount/dev/nbd0/mnt/nbd0 Reference link: Http://blog.csdn.net/gui694278452/article/details/7652450 Mounting

Iscsi discovery configuration and saving of nodes

Scenario: On Suse, the device discovery results are recorded in the/etc/iSCSI/node, which is effective upon startup and restart. In the RedHat system, the node found by the device is recorded in/var/lib/iSCSI/nodes. This file is created by the iSCSI initor program and can be found in/etc/init. d/iscsid service, view the START process, use this file. Fr

Iscsi workflow target and initiator

As enterprise-level data grows exponentially, traditional centralized storage solutions cannot meet their storage requirements. Therefore, the storage area network (SAN) technology is widely used, however, there are shortcomings such as short distance, expensive price, and complicated construction. The iscsi-Based IP Storage technology is a new network storage technology that integrates the IP network technology into storage I/O, what are the advantag

Two machines in Linux use iSCSI to complete a disk share from a server to B server

Idea: first need to support iSCSI function in two servers, then need to install two software server installation scsi-target....rpm inside the/cluster storge ./media/clusterstorage scsi-target-utils-1.0.8-0.el5.i386.rpm Client Install iSCSI ... Rpm in the/server/... Inside iscsi-initiator-utils-6.2.0.872-6.el5.i386.rpmThe server opens the shar

iSCSI Networked Storage Detailed

Server: Note: Firewall opens port 3260 (TCP,UDP) ********************************************************************************** Environment: ISCSI qualified Name (IQN) IQN string Format: Iqn. Iqn.2011-10.com.example.www:my.disk2 Experiment steps: Installation software: #yum Install Scsi-target-utils #chkconfig TGTD on #/etc/init.d/tgtd start #tgtadm--lld iSCSI--op new--mode target--tid=1-t Iq

To create an iSCSI disk on Windows Storage Server 2008

iSCSI disk as a resource required by the cluster, the application is more extensive, but the iSCSI provider is now generally provided by the hardware vendors dedicated storage equipment, but the current device is usually tens of thousands, not very economic reality, so the current variety of software iSCSI endlessly, With open source Openfiler and Microsoft's sto

is VMware vsphere storage connected to NFS or iSCSI?

VMware connects to shared storage in three different ways, San,ip sans (that is, iSCSI) and Nas (NFS). This article is not about the difference between the 3 and the SAN and NAS, please go to Google. Second, this article does not look at FC Sans, if your environment already has a SAN that supports MPIO and has enough storage space, try to make the most of it. Because many articles point out that Nas/nfs is an ideal medium for low I/O demand workloads

Update new NIC driver, fix win7 ralink nic ralink RT3290 blue screen netr28x.sys drive file error when PC sleeps and boot NIC

Update new NIC driver, fix win7 ralink nic ralink RT3290 blue screen netr28x.sys drive file error when PC sleeps and boot NICMy laptop is win7, ralink Nic Ralink RT3290 802.11bgn Wi-Fi AdapterAfter testing did solve the blue screen problem, download the network card driver here, install the update: NIC driver version:

Configure iSCSI using targetcli

Overview: This article introduces the user-state tool targetcli in Lio to configure the iscsi service. Virtual Machine environment: centos7.x (kernel version 3.10.0-862. el7.x86 _ 64) The IP addresses are 192.168.1.200/201, respectively. Targetcli Installation Centos generally comes with this tool. If you do not have it, you can download it from the official website. Quickly create IP-SAN 1. enter targetcli in the command line to enter the interaction

An example of an iSCSI fault

Tag: iSCSI detected conn error (1011) /Var/log/messages error description SEP 14 04:02:58 kernel: connection4: 0: detected conn error (1011) SEP 14 04:02:59 iscsid: Kernel reported iSCSI connection error (1011) State (3) SEP 14 04:03:01 kernel: connection3: 0: detected conn error (1011) SEP 14 04:03:02 iscsid: Kernel reported iSCSI connection error (1011) State (

Use openfiler2.99 under iSCSI to maximize logical volumes (command line)

Use openfiler2.99 under iSCSI to maximize logical volumes (command line) Use openfiler2.99 under iSCSI to maximize logical volumes (command line) Generally, a logical volume cannot be created in the Web mode to maximize its size. In this experiment, an iSCSI storage is used as an example. The openfiler2.99 operating system has just been set up. Log on to the Web

REDHAT7 Building iSCSI Target

REDHAT7 Building iSCSI TargetDividing new partitions (steps)# FDISK/DEV/SDC# partprobe (update partition table)Create a volume group first# PVCREATE/DEV/SDC1# vgcreate VGMING/DEV/SDC1# lvcreate-l 2g-n/dev/vgming/lvming# LvscanISCSI Target# yum Install Targetcli# TARGETCLI> Backstores/block create/dev/vgming/lvming> CD iSCSI/iscsi> Create Iqn.2016-03.com.ming:aa>

iSCSI Service and Client configuration (Redhat Liunx 7.0)

Providing iSCSI remote block storage servicesiSCSI Block Storage ConceptsThe Internet Small computer System Interface (iSCSI) is based on the TCP/IP protocol, simulating high-performance local storage buses, and reading and managing Remote Storage devices over IP networks. As a SAM protocol, iSCSI can provide storage services to Lan,wan.At present, the highest tr

Heartbeat+iscsi+mysql for dual-machine high availability

8, Heartbeat+iscsi+mysql realize dual machine high availabilityMigration of virtual addressesiSCSI provides storage sharing (MySQL is application also can be FTP web, etc. ) 650) this.width=650; "src=" Http://note.youdao.com/yws/res/21276/0B9FB083AE2248FEA35605DB7AC09BB7 "alt=" Qq20150730161150.png "/>on the iSCSI server: 10.0.2.220There are two disks required. /dev/sdb are used for sharing.(1) Installin

Microsoft's own iSCSI client requirements for IQN

Node Name:The Microsoft iSCSI Initiator strictly adheres to the rules specified for the ISCSI node name. These rules also apply to the Microsoft ISCSI initiator node name and any target node names that are discovered. The rules for building iSCSI node names, such as the iSCSI

Total Pages: 15 1 .... 6 7 8 9 10 .... 15 Go to: Go

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

not found

404! Not Found!

Sorry, you’ve landed on an unexplored planet!

Return Home
phone Contact Us
not found

404! Not Found!

Sorry, you’ve landed on an unexplored planet!

Return Home
phone Contact Us

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.