1. Install all SAS hard drive, boot up
2, the post process appears Ctrl + C prompts, press CTRL + C into LSI Logic Config Utility ...
Start SAS configuration
3, select the "SAS 1068" channel, press.
4, RAID select "Raid Properties", press
RAID Properties: Creating, managing arraysSAS topology: View Physical
The company has several servers installed on esxi5.0 virtual machines. They used to use common desktops, now we have purchased a dedicated server and installed the LSI 8708 sas raid card (the server's onboard RAID card esxi is not supported). Now we need to migrate the virtual machine.
The best method would have been to mount the array. Now the virtual machine is
raid Introduction: RAID (Redundant array of inexpensive Disks) is called a redundant array of inexpensive disks. The basic principle of RAID is to put multiple inexpensive small disks RAID level description; generally used RAID class, Are
equal sign, that is, the left side of the equal sign is equivalent to the right side of the equal sign. In other words, we only changed the original expression A without losing any information. It's like 24 = 2*3*4. Therefore, if LSI directly uses SVD, not only R is uncontrollable, but R is likely to be too large to achieve dimensionality reduction, in fact, this operation not only does not reduce the dimension, but also consumes a lot of computing t
Graphic RAID 0, RAID 1, RAID 5, RAID 10
RAID (Redundant Array of Independent Disk Independent Redundant Disk Array) technology was proposed by the University of California at Berkeley in 1987, initially to combine small cheap disks to replace large expensive disks, at the sa
originally. In addition to the reconstruction there is data risk.
In fact, most raid damage is not from good to paralysis, most of which will pass the downgrade this step, so the actual forced reconstruction of the file system is not a good practice, but the downgrade to the paralysis during the period of time if the data write is not much, Repair file system may be rebuilt after the change that the movie star downgraded to paralysis during this per
the server with Ubuntu system is turned on, but to see the status of the server RAID10, the LSI megacli Disk array management tool can be viewed by the following steps:1. Add Update sourcesudo vim/etc/apt/sources.list//add at the end
Deb Http://hwraid.le-vert.net/ubuntu Precise Main
sudo apt-get update//updating sourceNote: Some warnings can be ignored, but if you are prompted with a GPG error, you need to add a certificate
1. If you have multiple raid on a LSI array card, you may report hard disk error (CentOS 6.6) If you need to install the system on the first raid, or you can create a raid on the system first.
2. Hot Plug the consequences: If the hard drive does not fail, RAID is normal, in
VMware, on the official blog today, said the use of PVSCSI storage adapter driver can improve 10-30% performance for high IO VMs. See
Http://blogs.vmware.com/performance/2010/02/highperformance-pvsci-storage-adapter-can-reduce-cpio-by-1030.html
We know that the default type of SCSI controller when creating VMS is the LSI Logic. Now under vsphere 4, you can select a new type PVSCSI (the option is VMware paravirtual), and this type can significantly
When a new technology or product emerges, everyone is eager to know whether or when the new product will completely replace the original product. In fact, many products have a "long tail effect". For example, when a disk backup occurs, people think that the tape will soon exit the market, but today the tape is still the main force of backup and archiving; after the emergence of SSD, many people think that it will eventually replace the mechanical hard disk, but at least from now on, it is not ea
About the LSI 2208 array card is not enabled by default JOBD mode, how to configure as JBOD mode1, the server boot press ctrl+y into the BIOS preboot CLI interface2. Enter the command:$ Adpgetprop Enablejbod-aall (can be viewed to JBOD is disabled)Adapter 0:jbod:disabledExit Code = 0x0Enable JBOD$ adpsetprop enablejbod 1-aall (enable array card JBOD mode)Adapter 0:set JBOD to Enable success.Exit Code = 0x03, restart the server and press Ctrl+h to ente
With the development of LSI, the computer entered the fourth generation development. The fourth generation computer takes the large scale integrated circuit as the logic element and the memory, causes the computer to the miniaturization and the massive two direction development. From the first generation to the fourth generation, the architecture of the computer is the same, which is composed of controller, memory, arithmetic and input, called von Neu
Question: What is a RAID level? What does the raid level mean?
RAID technology is divided into several different levels, offering different speeds, security, and price/performance. Choose the appropriate RAID level to meet the user's requirements for storage system availability, performance, and capacity, depending on
Root tree enumeration and Its Application in LSI analysis and identification and Program Arrangement simplification
(Enumeration problemsCompleted by a student as a graduation thesis. I wrote the Application Section)
Root tree Enumeration
Requirement: write a program that includes {n} and {Non-standard root tree} A 1-1 correspondence is established between all elements.
The following table lists natural numbers.N = 1... 18Correspond
Recently, I was thinking about a cheap and convenient way to integrate cinder with LVM driver, that is, a raid hard disk consisting of cinder + LVM + multiple disks. In this case, you need to consider what raid should be used based on read/write requirements and available resources, and how to choose the raid mode. There are two
From RAID 0 to raid 6, different levels of RAID compromise in terms of performance, redundancy, and price. The purpose of combining different levels of raid is to foster strengths and circumvent weaknesses and generate a hybrid raid level with advantageous features. Commonly
Often someone communications raid, but it does not know its so dye, today I will be an example of Internet cafes to explain.With the expansion of Internet cafes, internet cafes will increase the number of computers, Internet users also increased, the speed of data access to the server will become a new bottleneck, many customers began to complain about the server on-demand film comparison card, game upgrade slow and other issues, if not to take releva
Raid implementation:Raid: cheap redundant disk array, which turns several hard disks into a wholeLater, because it lost its original cheap purpose and became very expensive, it changed its nameIndependent redundant disk arrayAlthough we cannot implement raid on hardware, we can still implement raid because of our limited strength and we didn't buy those devices.N
RAID (Redundant array of Inexpensive disks): Redundant array of independent hard disks, the basic idea is to combine multiple small hard disks together into a disk group to achieve performance improvement or capacity increase or redundancy through the management of software or hardware. Software RAID: The soft array provides the most basic raid fault tolerance th
RAID, or Redundantarrays of Lnexpensive Disks (RAID), is a fault-tolerant, inexpensive disk array.First, RAID-0Isometric mode-stripe for best performanceThis model is best if it is made up of two types of disks with the same capacity. This mode of RAID will cut the disk into equal chunks, and when a file is written to
The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion;
products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the
content of the page makes you feel confusing, please write us an email, we will handle the problem
within 5 days after receiving your email.
If you find any instances of plagiarism from the community, please send an email to:
info-contact@alibabacloud.com
and provide relevant evidence. A staff member will contact you within 5 working days.