1. Install all SAS hard drive, boot up
2, the post process appears Ctrl + C prompts, press CTRL + C into LSI Logic Config Utility ...
Start SAS configuration
3, select the "SAS 1068" channel, press.
4, RAID select "Raid Properties", press
RAID Properties: Creating, managing arraysSAS topology: View Physical disk and RAID configuration informationAdvanced Adapter Properties: View advanced attributes and their restore Defaults (this action do
The company has several servers installed on esxi5.0 virtual machines. They used to use common desktops, now we have purchased a dedicated server and installed the LSI 8708 sas raid card (the server's onboard RAID card esxi is not supported). Now we need to migrate the virtual machine.
The best method would have been to mount the array. Now the virtual machine is moved to the array and then to the new
equal sign, that is, the left side of the equal sign is equivalent to the right side of the equal sign. In other words, we only changed the original expression A without losing any information. It's like 24 = 2*3*4. Therefore, if LSI directly uses SVD, not only R is uncontrollable, but R is likely to be too large to achieve dimensionality reduction, in fact, this operation not only does not reduce the dimension, but also consumes a lot of computing t
About the LSI 2208 array card is not enabled by default JOBD mode, how to configure as JBOD mode1, the server boot press ctrl+y into the BIOS preboot CLI interface2. Enter the command:$ Adpgetprop Enablejbod-aall (can be viewed to JBOD is disabled)Adapter 0:jbod:disabledExit Code = 0x0Enable JBOD$ adpsetprop enablejbod 1-aall (enable array card JBOD mode)Adapter 0:set JBOD to Enable success.Exit Code = 0x03
the server with Ubuntu system is turned on, but to see the status of the server RAID10, the LSI megacli Disk array management tool can be viewed by the following steps:1. Add Update sourcesudo vim/etc/apt/sources.list//add at the end
Deb Http://hwraid.le-vert.net/ubuntu Precise Main
sudo apt-get update//updating sourceNote: Some warning
VMware, on the official blog today, said the use of PVSCSI storage adapter driver can improve 10-30% performance for high IO VMs. See
Http://blogs.vmware.com/performance/2010/02/highperformance-pvsci-storage-adapter-can-reduce-cpio-by-1030.html
We know that the default type of SCSI controller when creating VMS is the LSI Logic. Now under vsphere 4, you can select a new type PVSCSI (the option is VMware paravirtual), and this type can significantly
When a new technology or product emerges, everyone is eager to know whether or when the new product will completely replace the original product. In fact, many products have a "long tail effect". For example, when a disk backup occurs, people think that the tape will soon exit the market, but today the tape is still the main force of backup and archiving; after the emergence of SSD, many people think that it will eventually replace the mechanical hard disk, but at least from now on, it is not ea
With the development of LSI, the computer entered the fourth generation development. The fourth generation computer takes the large scale integrated circuit as the logic element and the memory, causes the computer to the miniaturization and the massive two direction development. From the first generation to the fourth generation, the architecture of the computer is the same, which is composed of controller, memory, arithmetic and input, called von Neu
Root tree enumeration and Its Application in LSI analysis and identification and Program Arrangement simplification
(Enumeration problemsCompleted by a student as a graduation thesis. I wrote the Application Section)
Root tree Enumeration
Requirement: write a program that includes {n} and {Non-standard root tree} A 1-1 correspondence is established between all elements.
The following table lists natural numbers.N = 1... 18Correspond
1. If you have multiple raid on a LSI array card, you may report hard disk error (CentOS 6.6) If you need to install the system on the first raid, or you can create a raid on the system first.
2. Hot Plug the consequences: If the hard drive does not fail, RAID is normal, in the system running state to hot plug hard drive, will cause raid different steps, the entire RAID may appear various strange problems,
For example: 1. HDD display off-line, red a
Latent Semantic Indexing is an algorithm that relies heavily on SVD. This article is reproduced from the summary of Wu Jun's beautiful mathematics and the reference document mathematics in machine learning.
------------
In natural language
. (generally used to reload the system or do not install the operating system to create a container (Adaptec array card)/logical drive (Ami/lsi array card).Use the Configuration tool software provided by the third party to implement the management of the card. such as Dell Array Manager. (These software is used on the server already has the operating system installed)Third, correctly identify the model of y
. (generally used to reload the system or do not install the operating system to create a container (Adaptec array card)/logical drive (Ami/lsi array card).Use the Configuration tool software provided by the third party to implement the management of the card. such as Dell Array Manager. (These software is used on the server already has the operating system installed)Third, correctly identify the model of y
power supply, which has a maximum output power of 500W, where the total output power of +3.3v and +5v is no more than 90W. From the server configuration, this server does not have the ability to directly extend the redundant power supply.
The PR1700G2 server is equipped with 1 Intel Xeon 2.8GHz Processors (800Mhz FSB,2MB L2), two 512MB Dd
, it can affect performance.Just as important as memory is the tuning of the disk system, which is especially important for the impact of the ESX server disk system. The disk hosting the ESX server kernel, as well as the kernel image, and the console system files should be equipped with RAID1 protectionWe do not recommend using on-board LSI for raid, 5i 6i 6m car
Text Description:
How to use LSI configuration RAID1
x servers have a number of integrated LSI SCSI controller models, press CTRL C at post to configure two hard drive mirrors. However, after upgrading the BIOS, some of the settings in CTRL C have changed, and the configuration method is somewhat different than the previous version.
Configuration steps for the new version:
1. Start the
Dell PowerEdge Server RAID card driver downloadDell new Array Card driver download
Model
Support System Driver
h310/710/710p/810
Win2008 x32
Windows 2008 x64
Windows 2008 R2
Windows 2012
h700/h800
Win 2003 x32
Windows 2003 x64
Windows 2008 x32
Windows 2008 x64
Windows 2008 R2
H200
Win 2003 x32
Windows 2003 x64
Windows 2008 x32
Windows 2008 x6
period, the iner is not redundant)
11) containers is created. Use the "ESC" key to launch and restart the computer.
Part 2: Create a logical drive (Logical Disk) --- perc2/SC, perc2/DC, perc3/SC, perc3/DC, perc3/DCL on the AIM/LSI disk array controller, perc4 di/DC (slightly different, please read the following documents carefully)* Note: Please back up the data on your server in ad
Domestic Professional Server rental hosting Chess Server game Server video server open area Hang -up serverWonderful solution! Ignore the attack!High-protection Special: website, game, chess best choiceHengyang Telecom (30G single-defense) 8h/8g/1t/exclusive 20M-800 yuanHengyang Double Line (30G single defense) 8h/8g/1
The IIS Server Load balancer ARR routes requests to the ARR server and the processing server. The Server Load balancer arr
. Net web uses the iis arr (Application Request Route) technology to achieve high web performance, high reliability, scalability, and load balancing. For more information about how to use ARR, seeI
The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion;
products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the