Windows OID uses SNMP for host information

size of the hard disk is 512*25157789 + 4096*2815383 + 4096*4096567+ 4096*11006525 =about 80GDisk usage size is 512*7427924 + 4096*861039 + 4096*16820 + 4096*5788717 =about 29GTotal HDD usage 29/80 *100% = 36.2%Physical memoryTotal RAM 65536*32754 = 2096256 KB, 2047.125M approximately 2G this number is about the same as the 1.3.6.1.2.1.25.2.2.0 result.Used RAM 65536*13270 = 829MMemory Utilization 829/2048 * 100% = 40.4%Memory size per chopsticks/block: Hrstorageallocationunits,1.3.6.1.2.1.25.2.

How to extract the device OID and add to cacti mapping! Get a full set!

First we look for oid! This thing to Baidu or manufacturers to find, such as Huawei to find a MIB reference650) this.width=650; "src="/e/u261/themes/default/images/spacer.gif "style=" Background:url ("/e/u261/lang/zh-cn/ Images/localimage.png ") no-repeat center;border:1px solid #ddd;" alt= "Spacer.gif"/>650 "this.width=650;" src= "http ://s3.51cto.com/wyfs02/m01/5b/fa/wkiom1uydjgjq-uwaaucafbh2zo132.jpg "ti

Structure and representation of MIB Object Names-snmp Tutorial

30.8 Structure and representation of MIB Object Names  We said that ASN.1 specifies what to represent both data items and names. However, understanding the names used for Mibvariables requires us to know about the underlying namespace. Names used for MIB variables is taken from the object identifier namespace administered by ISO and ITU. the key idea behind the object identifier namespace was that it provid

Usage of UCD-SNMP in MIB Module

In SNMP, I believe no one knows about the MIB module. Next we will introduce the preparation process of the UCD-SNMP defined by the MIB module. For details, refer to the article. A simple MIB module, next, try to expand several methods of ucd-snmp proxy program snmpd. First, write a MIB module definition file to be add

Troubleshooting Cannot find module (IP-MIB) under PHP

PhenomenonRecent work in the company's system to add some network-related features, it is based on Gatewayworker, after the launch report similar to the following error message:Cannot find module (IP-MIB): at line 0 in (none)Cannot find module (IF-MIB): at line 0 in (none)Cannot find module (TCP-MIB): at line 0 in (none)Cannot find module (UDP-

How to modify the oid of a table in PostgreSQL

Oid is a hidden column of the system. Direct modification is not acceptable.Mysql = # update pg_class set oid = 99999 where oid = 73728;ERROR: cannot assign to system column "oid"LINE 1: update pg_class set oid = 99999 where oid =

Monitoring Zabbix Custom OID

1. Script to write the monitoring service[email protected] ~]# cat mysqlstat.sh#!/bin/bashmysqlstat= ' ps aux | grep MySQL | Wc-l 'Echo $mysqlstat[Email protected] ~]#./mysqlstat.sh3[Email protected] ~]# snmpwalk-v 2c-c public localhost. 1.3.6.1.2.1.1.9.1.4.100snmpv2-mib::sysoruptime.100 = No Such Instance currently exists at the This OID[Email protected] ~]# vim/etc/snmp/snmpd.confextend. 1.3.6.1.2.1.1.9.1

Linux snmp oid's for CPU, memory and disk statistics

Systems (NMSS ). A managed device is a node that has an SNMP agent and resides on a managed network. these devices can be routers and Access Server, switches and bridges, hubs, computer hosts, or printers. an agent is a software module residing within a device. this agent translates information into a compatible format with SNMP. an NMS runs monitoring applications. they provide the bulk of processing and memory resources required for network management. SNMP mibs, oids Overview

Examples of MIB Variables-snmp Tutorial

30.5 Examples of MIB VariablesVersions 1 and 2 of SNMP each collected variables together in a single large MIB, with the entire set documented in a sing Le RFC. After publication of the second generation, Mib-ii, the IETF took a different approach by allowing the publication of many Individual MIB documents, specify th

Xubuntu-oriented MIB-Xubuntu topic

A mib-xubuntuplymotopic for XUbuntu is as follows: for detailed installation methods, see Ubuntu10.04 install MIB-ubuntupluth uth theme 1, sudocp-RMIB-Xubuntu/lib/plymouth uth/themes/2, sudoupdate-alternatives -- install/lib/plymouth uth/t A mib-XUbuntu Plymouth topic for Xubuntu is as follows: For details about the installation method, see "Install

Note PostgreSQL OID synchronization

Previously studied PostgreSQL's notesCREATE TABLE consumption OID create table My_ test_table, He's going to consume a pg_type insert two records _my_ test_table my_test_table oid If the table requires Toast will generate a change in the Toast Tables and Toast Index The table consumes another two, and the viewing process is as follows: CREATE TABLE my_test_table (a int,

Configure MIB writing during SNMP

We all know that MIB is a module in SNMP and is an indispensable part of SNMP. So next we will parse this part of MIB. First, you need to compile the pix mib on the SNMP manager. Compile the Cisco System Log MIB file to receive secure and failover SNMP events from the PIX Firewall. Compile and load the CiscoSMI

Get the OID value of a Cisco device

Tags: oid1, first landing equipment, check the device version;2, open the URL:https://www.cisco.com/c/en/us/support/web/tools-catalog.html, select Launch MIB Locator;3. Jump Web page, click Cisco IOS MIB Locator;4, jump page, enter version information, according to the SNMP version used to select the corresponding v1 or v2, to find the corresponding OID library ;

Monitor Zabbix User-Defined OID

Monitor Zabbix User-Defined OID Monitor Zabbix User-Defined OID 1. Write the Monitoring Service script [Root @ db02 ~] # Cat mysqlstat. sh#! /Bin/bashMysqlstat = 'ps aux | grep mysql | wc-l'Echo $ mysqlstat[Root @ db02 ~] #./Mysqlstat. sh3 [Root @ db02 ~] # Snmpwalk-v 2c-c public localhost. 1.3.6.1.2.1.1.9.1.4.100SNMPv2-MIB: sysORUpTime.100 = No Such Instance cur

How to modify the oid of a table in PostgreSQL

Oid is a hidden column of the system. Direct modification is not acceptable. Mysql # updatepg_classsetoid99999whereoid73728; ERROR: cannotassignt Oid is a hidden column of the system. Direct modification is not acceptable. Mysql = # update pg_class set oid = 99999 where oid = 73728; ERROR: cannot assign t

Management Information Library (MIB) Learning in Linux SNMP

The Simple Network Management Protocol (Linux SNMP) is first proposed by the Internet Engineering Task Organization (IETF) research team to solve the router management problem on the Internet. We usually seldom call a database in a managed device a database. In terms of Linux SNMP, it is usually called the Management Information Library MIB ). A mib describes the objects or table items contained in the data

How to modify the oId of a table in PostgreSQL

Oid is a hidden column of the system. Direct modification is not acceptable.MySQL = # update pg_class set OID = 99999 where OID = 73728;Error: cannot assign to system column "oid"Line 1: Update pg_class set OID = 99999 where OID =

How to view SNMP MIB

What is the MIB in SNMP? I believe you have some knowledge about SNMP MIB. This document describes how to view the local snmp mib. The specific operations are described in detail in this article. Run the following command on the cluster node to check the MIB: #snmpwalklocalhost-v1-cpublic This command should gen

Win 7 under Install Mib-browser version 8.0

Win 7 installs Mib-browser 8.0 version, install no problem, but always prompt at startup: failed to register OCX.Find the Help file found need to run the following two files (please note this you have to run the Regsvr32.exe utility from the MIB Browser ' s BIN folder.)regsvr32 mibpropc.ocxregsvr32 mgdchrt2.ocxHowever, when you run both commands, you are prompted: DllRegisterServer failed with error code 0x

Zookeeper LTE common system information-MiB, SIB

LTE system information is one of the key aspects of the air interface. it consists of the master information block (MIB) and a number of system information blocks (SIBs ). the MIB is broadcast on the physical Broadcast Channel(Pbch), while sibs are sent on the physical downlink shared channel (pdsch) through radio resource control (RRC) messages. sib1 is carried by "systeminformationblocktype 1" message. si

Total Pages: 15 1 2 3 4 5 6 .... 15 Go to: Go

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.