Preface
Prior to using RABBITMQ to deploy a simple MQTT server, no user isolation, but also deployed the Influxdb sequential database, but can not directly through the configuration of the MQTT server data to the Time-series database, so I decided to write my own script implementation. Ready to
Open shell UsePip Install influxdb install inluxdb required modulesPip Install Paho-
Design Scenario 1:On the PLC, when using qdial to adjust the volume, trigger the Qdial signal:valuechange (), corresponding slot sends the custom key code 0x22 to LPC;On LPC, when the 0x22 key is received, the operation: set the current volume value, when the setup is complete, the PLC will receive the volume data from LPC to update.Problem found:1, when the trigger valuechange () signal, due to LPC set 3s
PLC Learning 1
By: Chen Hao
Hardware plc: OMRON cp1h xa40dr-a.
Example 1
Function Description: One switch controls one lamp.
Hardware wiring :.
L1 and L2/N: connected to AC 220 V
COM and 00 (0ch channel): Access the Input Switch DC 24 V (I corresponds to the input address of 0.00)
COM (first from the left of 100ch) and 00 (100ch): both ends are equivalent to one switch. 220v power supply and 2
Because of a variety of reasons colleagues are very unpleasant to go, equipment is not moving up, is my life.Write a simple program, debugging equipment, the results of colleagues said the problem, not only the motor is not controlled. I had to check the program from the beginning, because the program is very simple, so certainly not a procedural problem. After a few troubleshooting equipment, it is found in a connection between the stepper motor driver direction control of the terminal and the
St language is one of the 5 standard languages stipulated in Iec61131-3, the PLC which is commonly used to see the brand supports this language (Schneider, AB can directly choose to create this type of program segment or function block, Siemens a little Trouble), one of the advantages of St language is good transplant, The St language of the family is basically similar, so if there is a giant good algorithm, with St language implementation is no bette
Objective:MQTT is an Instant Messaging protocol developed by IBM. MQTT is a connectivity protocol for both the machine and the internet of Things, with lightweight publishing and subscription messaging.You can directly on GitHub download MQQT service source code, source address: https://github.com/mqtt/mqtt.github.io/wiki/librariesMain content:Official Document Translation:The M2MQTT library provides a main
His page attempts to document the features, various MQTT servers (brokers) support. This was specific to their MQTT support; Many of these servers have much wider capabilities beyond just MQTT.Capabilities
Server
QoS 0
QoS 1
QoS 2
Auth
Bridge
$SYS
SSL
Dynamic Topics
Cluster
WebSockets
Plugin System
2lemetry
?
Wolfram Hempel is the co-founder of Deepstreamio. Deepstreamio is a German-based technology start-up company that provides high-performance, secure, and scalable real-time communication services for mobile clients, as well as IoT devices. Text translated by Jiatong, please specify from the highly available architecture.
Want to send a request to the server and get a response? Use HTTP directly! Very simple. But when you need to communicate through a long-lasting two-way connection, such as
ObjectiveMQTT (Message Queuing Telemetry Transport), an IoT transport protocol, is designed for lightweight publish/subscribe messaging, designed to provide reliable network services for IoT devices in low-bandwidth and unstable network environments. MQTT is a lightweight transport protocol developed specifically for the Internet of things. The MQTT protocol is optimized for low-bandwidth networks and low-c
1. Introduction of Mosquitto Warehouse and update
$sudo apt-add-repository Ppa:mosquitto-dev/mosquitto-ppa
$sudo apt-get Update
2. Install the Mosquitto package by executing the following command
$sudo Apt-get Install Mosquitto
3. Installing the Mosquitto Development Kit
$sudo apt-get instal Llibmosquitto-dev
4. Installing the Mosquitto client
$sudo Apt-get Install Mosquitto-clients
5. Query whether Mosquitto is running correctly
$sudo Service Mosquitto Status
6. Native Test
Op
Today, writing a study note of the PLC, this article will introduce the most basic operation of the PLC and control instructions, this article will be directly on.1. Basic Arithmetic Operation instruction1) Integer arithmetic2) Long integer operation3) Real arithmetic、STL Programming Example (arithmetic operations for 16-bit integers)liw10//the input word IW10 load accumulator 1 Low word lmw12//the accumula
Http://emqtt.com/docs/v2/guide.html1 The default is anonymous authentication, without entering the user name and password, directly can connect2 How to turn on user name and password Authentication mode2-1 Turn off Anonymous authenticationUnder your MQTT installation directory, go to the folderEtc/emq.conf Configure enable Anonymous authentication:# # Allow Anonymous authenticationTrue()2-2 Setting up configuration filesUser Name Password Authenticati
Tag: Polling an MQTT message through a two-way synchronous device Server communication protocolWe know that the device used by the user is called the client, and the port that is provided to the user information is called the server side. Two ports can be interacted with through a variety of communication protocols, such as HTTP (synchronous) or message-based asynchronous.The MQTT protocol has the advantage
Both client:
pub_1.pyImportPaho.mqtt.client as MqttImport TimeImportSYSImportRandomdefon_connect (client, UserData, flags, RC):Print("connected with result code"+str (RC))defon_publish (client, UserData, mid):Print("Publish au/csie/5/9/5912/temperture",) client=Mqtt. Client () Client.on_connect=On_connectclient.on_publish=On_publishclient.connect ("iot.eclipse.org", 1883, 60) whileTrue:Try: With open ("C:\\users\\86390\\desktop\\test_s.txt","R") a
Domestic Android devices, can not stabilize the use of Google GCM (Google Cloud messageing) message push service.
1. Domestic Android devices, basically from the bottom of the operating system to remove the Google framework
2. Google servers are abroad, the most recent in Hong Kong, and other reasons, causing domestic mobile phone and Google server connectivity instability
3. Some enterprise customers also do not want to use public services, it is best to use their own intranet to push the se
1. Server Installation: ibm rsmb (MQTT protocol proxy) ReallySmallMessageBroke (rsmb_1.2.0) download. csdn. netdetailwuzehai024735055 install TostartthebrokeronWindows: kernel.
1. server Installation: ibm rsmb (MQTT protocol proxy) Really Small Message Broke (rsmb_1.2.0) http://download.csdn.net/detail/wuzehai02/4735055 installation To start the broker on Windows: In the folder where you installed the broke
the event action when the event occurs and disappears, through the event trigger condition, can open the picture, play the sound, execute the *.exe executable program and set the variable value, etc.2.5 Real-time databaseThe user specifies the data storage method, which can be stored in the database by timing, conditional expression and rate of change.2.6 Control StrategyWith FBD61499 graphical programming, users can complete advanced complex control with simple drag-and-drop and wiring. Input
The timers in the PLC are placed in a specific PRG task unit, and the PRG unit needs to be placed in a specific periodic cycle task in order to be executed, and this cycle cycle task cycle T; The timing time of the timer T0; T and T0 The order of magnitude, or size determines the accuracy of the timer.Ttest:ton;Uicount:uint;TTest (in: = Not ttest.q, PT: = t#2s);IF TTEST.Q ThenUicount: = uicount+10;End_ifSituation one: T0 > > t (Timer T0 (seconds) time
Double-click Plctask, and then cycle ticks to modify the PLC scan cycle, for example, modified to 2ms?In order to verify whether it is really 2ms, can be used in the program with the counter binding, PLC2MS scan once, the counter is also increased by 0.002 per cycle, so you can see whether the time is one second of the increase.?In TC2, you need to switch to the task configuration and then navigate to a task (default is standard only), and then modify
PLC Ladder diagram Programming exercise
Traffic light ControlWhen the SW2 is off, it is easy to turn the traffic lights on and off, but when the SW2 is turned on (ie into the night mode), the red and green lights are not lit when the simulation is added.I guess the reason is that the ladder control of the one by one corresponding principle in the night mode to join the ladder after the problem, I did not find out the specific problem, did not th
The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion;
products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the
content of the page makes you feel confusing, please write us an email, we will handle the problem
within 5 days after receiving your email.
If you find any instances of plagiarism from the community, please send an email to:
info-contact@alibabacloud.com
and provide relevant evidence. A staff member will contact you within 5 working days.