. Advantage: Data read performance is improved, and data write performance is no different than a single disk. 100% data redundancy means that there is no need to rebuild data in the event of a disk failure. It is important to note the inefficient use of disk capacity-the highest cost for all RAID types (100%).3,RAID10 Features: RAID-10 is a combination of RAID-1 and RAID-0. This configuration requires at least 4 hard drives, with the best performance, protection, and capacity in all RAID levels
In many cases everyone is convinced of the theory, the theory is conditional, not all cases are correct. The company has a server, so the disk performance test, of course, the results of testing is only sequential I/O performance test (DD mechanism determined).Prerequisites: (DELL R630 physical Machine test, memory 64G)RAID5 5 block (600G SAS) + 1 (GHS)RAID10 6 block (600G SAS) + 0 (GHS)* When testing to ensure the authenticity of the test results, ma
block data and distribute data on different disks, but the disk unit is block or record. raid 4 uses a disk as the parity disk. Each write operation requires access to the parity disk, which becomes the bottleneck of write operations. It is rarely used in commercial applications.RAID 5: RAID 5 does not have a specified parity disk. Instead, it accesses data and parity information on all disks. On RAID5, read/write pointers can be performed on the arr
store inspection and recovery information, making raid 2 more complicated. Therefore, it is rarely used in commercial environments.
RAID 3: Unlike raid 2, RAID 3 uses a single disk to store parity information. If a disk becomes invalid, data can be regenerated on the parity disk and other data disks. If the parity disk is invalid, data usage is not affected. RAID 3 provides a good transfer rate for a large amount of continuous data, but for random data, parity disks will become the bottleneck o
and mirroring, it is called a raid 0+1.
RAID5: Distributed parity independent disk architectureFrom its schematic, it can be seen that its parity code exists on all disks, where the p0 represents the parity value of the No. 0 band, and the other meanings are the same. The efficiency of RAID5 is very high, the writing efficiency is general, and the block-type collective access efficiency is good. Because p
RAID5 's name changed after Linux reboot
Use raid , the device path will be changed after each rebootFor example, the original /dev/md0 Rebooting once became /dev/md127This problem can be resolved by using the Modify configuration file.1, Mdadm-ds >>/etc/mdadm.confinput mdadm-ds Separately, outputDescription: This command is toThe data from the mdadm-d output is appended to the mdadm.conf file. The mdadm.conf file does not have this command to create
Part I: Data recovery programme
"User Unit" a pharmaceutical company
"Fault description"
IBM X3850 Server, 5 73G SAS hard Drive, where 4 pieces make up one RAID5, the other as a hot spare (hot-spare), 3rd disk is already offline, but the hot spare is not automatically activated rebuild (unexplained), after 2nd disk offline, RAID crashes.
Operating system for Linux Redhat 5.3, Application systems for the architecture of an Oracle OA, the data is im
"Customer Name": Binzhou Wudi County Hospital of Shandong Province"Software name": Zhong Lian Jia Yu His hospital information management system"Database Version": MS SQL Server 2008R2 "database size": 48GB."Problem description": On the eve of the Lunar New Year, the customer due to server hard disk damage, causing RAID5 serious damage. It also affects all hot backup disks, all of which are covered by damaged files damaged by the main disk. Lead to the
1. Server Data Recovery failure descriptionToday, the data recovery of the server failure situation for the hard disk offline, the fault server is a group of hard disks consisting of a set of RAID5 disk array, due to the server's hard disk dropped the server crashed, the administrator check the server found that both hard disks have physical failure, To recover data you must first fix the physical failure of the dropped hard drive.2. Hard Disk physica
Build RAID5, LVM, and SAMBA server (5) on CentOS 7 -- set up SAMBA Server
Build RAID5, LVM, and SAMBA server (5) on CentOS 7 -- set up SAMBA Server
6. Set up a SAMBA Server6.1. PreparationsThe task in this section is to configure the SAMBA service, share the/home/shared directory, so that the specified Windows user can remotely access the sharing.First, run the yum command on CentOS to install the SAMBA ser
If the total capacity of the hard disk is greater than 2T, the system cannot be installed in MBR format.Use GPT formatYou can't use Fdisk to partition it at this time.To use parted to partitionMore than 2t hard disk partition, the old boy video used to 5 pieces of 600G hard diskThere are several ways to install the systemI only remember two of them.Method One: Take 2 pieces of RAID 1 for the remaining 3 pieces to do RAID5Method Two: All made RAID5, th
Question: How do I restore the RAID1 or RAID5 of the ServeRAID 7T card?
Workaround: RAID1 or RAID5 a hard drive failure, please refer to the following steps to recover the array.
First, press CTRL+M to open the BIOS Configuration tool when the following prompts start up
1, Automatic mode
If a hot spare is available, it is automatically restored
Select Management menu-> objects-> physical Drive to displ
This document takes the Sun Fire V880 Server (6*73GB Dsik) as an example to explain how to install and maintain Solarsi8 and RAID1 using the command line in RAID5. The contents of this document have been verified by my practice, but for different models for reference only, thank you for your support!
Disk Distribution:
0:c1t0d0
1:c1t1d0
2:c1t2d0
3:c1t3d0
4:c1t4d0
5:c1t5d0
Note: 0,1 do mirror; 2,3,4,5 do RA
Tags: database storage raid Data recovery"RAID Data Recovery failure description"Huawei S5300 Storage, storage for 16 FC drives, the entire storage space consists of a RAID5 disk array of 450GB FC disks (including a hot spare). The storage of the RAID5 array 3rd HDD offline due to unknown reasons, hot spare disk on-line and data synchronization, synchronization completed to 50% or so when the 8th disk due t
case: Building a soft RAID disk arrayRequirements Descriptionadd to Linux server 5 Block SCSI hard diskUse the Mdadm software package to build RAID5 + Hot Spares array for improved performance and reliability of disk storage⑴ installation Mdadm[Email protected] ~]# Rpm-qa |grep mdadm⑵ preparing partitions for a RAID array① add 5 SCSI hard disks to the Linux server and use the Fdisk tool to carve out a 2GB partition:/DEV/SDB1,/DEV/SDC1,/dev/sdd1,/dev/s
1
1
1
--1
Understand the concept of XOR operation from this model: the result of an even number of 1 is 0, the result of odd number 1 is 1;Plot RAID 5The principle of the raid is to use bit striping and the current mainstream block striping partition method, the data is distributed to each hard disk, when the hard disk is damaged by the XOR operation, there will be other hard disk parity blocks and data The data blocks of the stripe magnetic region is ca
Powering on or restarting the server
When the interface runs to the following figure, press CTRL + H
Enter the interface below and click the Start button
Click the Clear button to erase the previous array
Click the Yes button
Select Configuration Wizard
Click Next button
Continue to the next step
Select the left box, turn on all detected hard drives, and then click Add to array for the right group
Are added to the right, click the Accept DG button
Then click Next
The previous section describes the synchronization functions in RAID5 sync_request potato chips are made by handle_stripe. From the initial creation of the array, to the application of various resources, to build the personality of each array, everything is prepared to meet the data flow. It's like we're cramming for college. The process of data flow is as rich and challenging as a college campus, but as long as it crosses the line, the kernel code wi
New network, Enterprise mail server, stored in the 146gx6 RAID5, there are millions of enterprise users of the mail, data area, only one district, file system for ReiserFS, normal work, RAID suddenly offline, the administrator to the computer room inspection, found two disk alarm, After one of the forced online found that the volume could not mount, so forcibly fsck and Rebuld tree, lasted 4 days, after completion still cannot mount. Unfortunately, mo
The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion;
products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the
content of the page makes you feel confusing, please write us an email, we will handle the problem
within 5 days after receiving your email.
If you find any instances of plagiarism from the community, please send an email to:
info-contact@alibabacloud.com
and provide relevant evidence. A staff member will contact you within 5 working days.