netapp hq

Discover netapp hq, include the articles, news, trends, analysis and practical advice about netapp hq on alibabacloud.com

Related Tags:

EMC, pure and NetApp push new products, where are NAS flash scenarios

-weight:inherit;font-size:inherit;line-height:inherit; font-family:inherit;vertical-align:baseline; "alt=" 17ef0004799bdd53b8b8 "/>The new all-flash Isilon does not use NVRAM to save logs, but instead uses flash memory directly. All-Flash Isilon actually has only one hardware form, placing 4 nodes in a 4U chassis. Each node supports 15 SSD disks. The capacity of the disk can be selected, there are three kinds of 1.6TB,3.2TB,15.4TB. The interconnect interface of the node must be IB or 400,000 tri

"NETAPP" Configuration Vscan Features

NETAPP can use the Vscan feature to connect an external virus scanning server (such as McAfee) to detect the CIFS share on storage. The configuration is as follows:Virus detection software:1) Install McAfee VirusScan Enterprise 8.8 Patch 7:https://www.mcafee.com/apps/downloads/free-evaluations/default.aspx?pc=productcategorypid=eid= Pg=2sz=25srt=descriptionsd=ascregion=us2) Installing the plugin McAfee VirusScan Enterprise for StorageDownload Link: ht

Configuring Vscan in the "NetApp" 7mode Environment

Using McAfee as an example, primary scanner is registered via RPC, and on a NetApp 7mode controller, only the user name (that is, the Daniel user in) that primary scanner is used. Join the Backup Operter Group permission level above the NetApp controller in the group.Virus detection software:1) Install McAfee VirusScan Enterprise 8.8 Patch 7 on Vscan server:https://www.mcafee.com/apps/downloads/free-evaluat

NetApp storage inodes overrun, resulting in insufficient app reporting space

The application layer accesses the NAS report the following error, although the space is sufficient, but it is not enough to report space,650) this.width=650; "title=" QQ picture 20141112104654.jpg "alt=" wkiom1rizdvjjurxaae4l_ypmlm148.jpg "src="/http S3.51cto.com/wyfs02/m02/50/e4/wkiom1rizdvjjurxaae4l_ypmlm148.jpg "/>Enter the storage, found the following error.Vol status a_wed Nov 10:09:29 CST [ac-idc-metro1:wafl.vol.outofinodes:notice]: File system on Volume a_documentum is OU T of InodesIt t

NETAPP F3220 Storage related access to direct Connect port information

interface identity is viewed as shown:650) this.width=650; "title=" wps_clip_image-13185 "style=" border-right-width:0px;background-image:none; border-bottom-width:0px;padding-top:0px;padding-left:0px;padding-right:0px;border-top-width:0px; "border=" 0 "alt = "wps_clip_image-13185" src= "Http://s3.51cto.com/wyfs02/M00/7E/56/wKiom1b8xRTy_7nXAAL4vOP1XMg723.png" width= "574 "height=" 159 "/>Through the above method, we can find other direct connection information or non-straight connection informa

VNX NETAPP NAS Backup Recovery

How many times a snapshot is made is customized, such as it can be done every 4 hours.For example there are a,b,c,d of four files.1) First Snapshot (COW):The snapshot is instantaneous, when the camera creates a snapshot space, for example, 20%, then changes the a file to A1 (the change is compared to the time of the photo), Checkpoint/snap shot is a file, and then back up the CK. Restore the words according to CK's pointer (pointing to the source file) +ck file (a file before the change) to reco

"NetApp" the owner of disk after the ADP partition is removed

1) Remove owner, need to enter node mode, type the following command:Cluster1-01*> Options Disk.auto_assignDisk.auto_assign off (value might is overwritten in takeover)Cluster1-01*>cluster1-01*> Disk Remove_ownership 0B.00.11P1Volumes must be taken offline. is all impacted volumes offline (y/n)?? YCluster1-01*>cluster1-01*> Disk Remove_ownership 0b.00.11p2Disk Remove_ownership:disk 0b.00.11p2 is already unowned.Disk Remove_ownership:remove ownership failed because the specified disks is already

A data storage solution for an oil field in NetApp

-end, how to flexibly partition and dispatch the capacity between multiple server platforms is also a great challenge to the management of storage systems. --from the overall requirements of the tender, fully consider the requirements of the backup system, the use of mature and reliable LAN free backup technology, to achieve large data volume of high-speed backup, to reduce the burden of system managers, to ensure that the handlers and interpreters even when the backup can work properly. 2. Sc

Connection and configuration of Netapp Nic and external Switch

Connection and configuration of Netapp Nic and external switch 1. Netapp Nic setting category: www.2cto.com. single mode usually uses two interfaces as single mode to connect two external switches. At the same time, only one port has data streams. (NA's single mode redundancy) B. multi mode generally has two interfaces for multi mode, which are connected to one external server or two stack switches. At the

Adjust the NetApp storage display name

Adjust the NetApp storage display nameStorage Management page--expand Storage Name--configuration--network--network files--/etc/hosts--Check the name 1 lines--editThen SSH to the storage> rdfile/etc/hosts (confirm the configuration file)> Hostname netnas1 (write to storage memory)Re-open storage page, store display name changedThis article is from the "Linux" blog, so be sure to keep this source http://yangzhiming.blog.51cto.com/4849999/1904487Adjust

NetApp Patrol Commands

NetApp Patrol CommandsSysconfig-aSysconfig-rEnvironment Status allRdfile/etc/messagesAggr status-v################################Sysconfig-aSysconfig-rSysconfig-caSysconfig-vVersion-bDf-hDf-ahDf-agDf-iDf-gLUN ShowLUN show-vLUN show-mIgroup show-vAggr Status-rAggr status-vSIS statusVol statusVol status-vVol status-sVol status-fSnap ListSnap ReserveSnap Reserve-aSnap SchedSnap Sched-aCF statusCF MonitorDNS InfoCIFS DomaininfoCIFS sharesEnvironment Sta

NETAPP 7MTT Tools for migration of stored data

1 NetApp 7MTT Tools for migration of stored data 1.1 7MTT Migration Process 650) this.width=650; "title=" clip_image002 "style=" border-top:0px; border-right:0px; Background-image:none; border-bottom:0px; padding-top:0px; padding-left:0px; border-left:0px; margin:0px; padding-right:0px "border=" 0 "alt=" clip_image002 "src=" http://s3.51cto.com/wyfs02/M00/96/95/ Wkiom1kjnbeaigcoaabgf17uv0y074.jpg "" 229 "height=" 244 "/> Pr

Anon parameter of export policy in "NETAPP" 7mode

1)/vol/volnfs-sec=sys,rw,anon=0,nosuidAt this point, all NFS client root users can change file and folder permissions using Chmod. With the anon=0 parameter, the root=192.168.10.90:192.168.10.91 parameter is superfluous (because anon grants root access to all NFS client root users on NetApp).2)/vol/volnfs-sec=sys,rw,anon=65535,nosuidSetup anon=65535 can do this, the root user of NFS client cannot read and write, but the normal user of NFS client can r

EMC, pure and NetApp push new products, where are NAS flash scenarios

selected, there are three kinds of 1.6TB,3.2TB,15.4TB. The interconnect interface of the node must be IB or 400,000 trillion, capable of scaling up to 100 chassis, or 400 nodes, capable of supporting up to 100PB capacity.NetApp released the All-Flash AFF 8000 series last year after a series of restructurings (EF series, Flashray) and acquisitions (SolidFire) in the flash market. This product improves performance and data management capabilities. Improve flash performance and efficiency with sof

Some of the errors encountered during the "NETAPP" Snapdrive installation

Error message 1:Failed to get Data ONTAP version running on the storage System netapp814b as it was not reachable. Ensure proper network connectivity and make sure the ... "Error:Cause of Error:After troubleshooting various snapdrive and storage controller network problems, because the error is generated in the simulator experiment environment, NETAPP 7mode is the same as the system ID of the DATAONTAP simulator, so the use of snapdrive do update Snap

Quotas and disk replace on NetApp

sa:b 0 bSAS 7200 1695466/3472315904 1695759/3472914816Data 0a.01.110a 1 sa:b 0 bsas 7200 1695466/3472315904 1695759/3472914816Data 0a.01.9 0a 1 9 sa:b 0 bSAS 7200 1695466/3472315904 1695759/3472914816POOL1 spare disks (empty)POOL0 Spare disksRAID diskdevice HA SHELF BAY CHAN Pool Type RPM Used (mb/blks) Phys (mb/blks)--------------- ------------- ---- ---- ---- ----- -------------- --------------Spare Disks for block checksumSpare 0a.01.7 0a 1 7 sa:b 0 bSAS 7200 1695466/3472315904 1695759/34729

NetApp FAs storage LUN expansion in vSphere5.5

1, login OnCommand, find the LUNs that need to be expanded, and add capacity, save and close.2. Refresh all volumes on VSphere client, find this LUN, click Add.3, the next step until the completion.Note: It remains to be seen whether other brands of SAN storage support this.650) this.width=650; "src=" http://s3.51cto.com/wyfs02/M00/71/A1/wKiom1XVO0yC8hmUAAPNtP7m0Us181.jpg "title=" 1.jpg " alt= "Wkiom1xvo0yc8hmuaapntp7m0us181.jpg"/>650) this.width=650; "src=" http://s3.51cto.com/wyfs02/M00/71/A1/

. NET: how to obtain the parameter values in the App. config configuration file,. netapp. config

. NET: how to obtain the parameter values in the App. config configuration file,. netapp. config First add System. Configuration reference Class file must contain using System. Configuration; Add App. config Add parameters to the App. config configuration file Example: In this App. config configuration file, I added four parameters. The App. config parameters, like HashTable, are key-value pairs. How can I access the parameter values in the App

View NetApp Storage Real-time performance statistics using the statistics command

-right:0px "border=" 0 "alt=" image "src=" http://s3.51cto.com/wyfs02/M02/8F/99/ Wkiom1jmee2t6bjeaait8ewgkku228.png "" 711 "height=" 594 "/> Figure 9IOPSRefer to Figure 2, 8, 9, query ioPSCifs/nfs operationQuerying the most active users (Cifs/nfs read and write operations with the largest number of users) Cluster1::* > Statistics Top client Showcluster1:12/27/2016 01:33:56*totalClient Vserver Node Protocol Ops------------- ------------ ----------- -------- ------192.168.0.253 CIFS_NFS_SVM cluste

"NetApp" uses PowerShell mount and Umount Volume

1) Connect Dataontap cmode ControllerConnect-nccontroller 10.20.30.40 The IP address is the cluster administrative address.2) Mount Existing volumeMount-ncvol-name Nfsvol3-vservercontext Cifssvr-junctionpath/nfsvol33) Umount VolumeDismount-ncvol-name Nfsvol3-vservercontext CifssvrBatch Mount Volume$vols =get-ncvol$paths= ($vols |where {$_. Name-ne "Volcifsroot"-and $_. Name-ne "Vol0"}).name$fpaths= $paths | foreach{"/" + $_} for ($i =0; $i-lt $paths. Count, $i + +) {mount-ncvol-name $paths [$i]-

Total Pages: 15 1 .... 3 4 5 6 7 .... 15 Go to: Go

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.