I.. configuring a KVM Server1. Configure Virtio Sourcewget Https://fedorapeople.org/groups/virt/virtio-win/virtio-win.repo-O/etc/yum.repos.d/virtio-win.repo2. Install related software packagesYum Install virt-v2v Libguestfs-winsupport Virtio-winSecond, prepare to be converted Server1. If the server being converted is CentOS, you need to close SELinux2. Turn off random startup of all business systems on the serverIii. converting a physical server to a
The first thing after the enterprise builds the virtualization platform must be to transfer the existing server application business to the virtual server, which is the first step of the virtualization consolidation server and one of the basic functions of the Virtualization program: P2V conversion function.AD:The first thing after the enterprise builds the virtualization platform must be to transfer the existing server application business to the vir
VMM2008 allows the administrator to transform the physical host that exists in the production environment to the Hyper-V virtual machine, which is often referred to as production to virtual conversion. Also known as P2V. The Migration (Transformation) wizard through the VMM Management console makes it easy to implement P2V.
I. VMM and P2V INTRODUCTION
VMM 2008
Lab 18 SCVMM physical computer to Virtual Machine (P2V) the P2V function in SCVMM2012 can convert a Windows system on a physical host to a virtual machine without interrupting the services of the physical host (the physical host can be in a domain or peripheral network ), the acceleration administrator migrates the physical environment to virtualization. However, different levels may be involved in this pro
System Center Virtual Machine Manager 2008 's P2V feature converts the actual physical server into a virtual machine. The physical server must be added to Active Directory and managed by a domain administrator or authorized user. The transform physical server provides a transformation wizard that automates the collection of information such as physical computer hardware information, operating systems, and installed
Tags: BSP target ITER event user table copy host information testzhuan:1190000002697929This article is a complete record of how to keep all the environment configuration information from the physical server, motionless migration to the virtual machine, commonly known as P2V. The tools used are VMware, which VMware vcenter vconverter standalone supports the use of Windows and Linux operating systems as a source and can perform several transformation ta
Formal step start: Fill in the Red box account information about the physical machine to be converted to the virtual machineSelect the destination host to which you want to convert the virtual host, fill in the relevant account informationSet conversion parameters: Note Here about the disk settings, note: If the source system is LVM, the disk volume does not convert it to a basic disk mode, it will not be able to mount the LVM volume group to/sysroot when the virtual machine is started at the en
Linux processing after P2V/boot/sh-3.2# mkinitrd-v-F initrd-2.6.18-164.el5.img $ (uname-r)Kernel file name kernel version number to package# #更新当前虚拟机的内核;#如果修复光盘与系统不一至的情况: $ (uname-r) here directly knocks the kernel version number of the virtual machine;Problem set:The "Error loading operating system" message appears on boot, just use the disc to enter recovery mode, fix grub to boot up, and make sure that your virtual machine hard disk type is SCSI LS
url ("/e/u261/lang/zh-cn/images/localimage.png") no-repeat Scroll center;border:1px solid RGB (221,221,221); "alt=" Spacer.gif "title=" 6.png "width=" 554 "height=" 412 "/>7, in the options interface, you can make changes to the size of the disk, memory size, network, etc., we choose the default directly click the "Next" button to continue, as shown:650) this.width=650; "Src=" Http://s2.51cto.com/wyfs02/M00/8C/0D/wKiom1hgiRaD56sLAAEzCfMpJsg746.png-wh_500x0-wm_3 -wmp_4-s_1063198363.png "style="
Using VMware Converter Standalone to convert a physical Linux times wrong, run to 97% when cancel,LSB version:1.3Distributor Id:redhatenterpriseesdescription:red Hat Enterprise Linux ES Release 3 (Taroon)Release:3Codename:taroon2014-06-25t14:02:30.503+08:00 [02576 info ' Default '] [task,379] [task-8]--ERROR--Convert:converter.fault.CloneFault--(Converter.fault.CloneFault) {--DynamicType = --Faultcause = (vmodl. Methodfault) NULL,--Description = "Grubinstaller::installgrub:/usr/lib/vmware-conver
The above section analyzes most of the structure of enterprise content:http://zhangfang526.blog.51cto.com/8588740/1772382So what can we do with a switch or Dell VRTX?First look at the following diagram:650) this.width=650; "src=" Http://s2.51cto.com/wyfs02/M00/7F/FC/wKiom1czMp-CvgLXAADWjvhYZU4559.png "title=" 4.png " alt= "Wkiom1czmp-cvglxaadwjvhyzu4559.png"/>FirstTo separate the data network from the management networkSecondDELL VRTX has 8 external ports (in SW mode), then we use four lines as
Project requirements:installation Dellvrtx hardware, and connect to the customer's production network while establishing virtual machines to achieve customer RODC and P2V requirements. Stage One, installation Dellvrtx Hardware, and complete the following requirements:1. Dell Enclosure and Blades-Mountingof Enclosure to Rack-Ensureeach Blade Server has the components installedA) 2x CPUb) 64GB RAMc) 2 x 300GBSAS-Ensureenclosure have a total of 15x 900GB
VMware vcenter Converter Standalone is an important tool for P2V to migrate operating systems such as Windows,linux, but there are often some details that can be unsuccessful, this article through VMware vcenter Converter standalone6.1.1 Tools successfully migrated the Dell R310 Legacy Server (Centos5.8 x64) to the ESXI6.0U2 virtualization platform, now through virtual machine simulation and recording process and processing mode.First, the matters nee
Encounter a problem, record, and later can think of when I was young to work for that client, prostitution .....What ' s the fuck ...First introduce the following background and requirements:Our customers do not know where to install the broken windows 7, now to migrate to the same site of VMware ESXi as an application server to use ... (P2V needs of the egg ache)The VMware ESXi environment is cluster, and the version is 5.0.The version of VMware Conv
with the Web version, we can completely ignore that operating system, because these firmware is the same content, but it is best to use the Windows firmwareThird If you want to upgrade SPREC8 content, must be for the system to do, on the official DELL website on the EXSI6 firmware , because this does not need to install, directly can use At the same time, to establish the HA mode, we must first upgrade him to a shared way, at the same time select Master-slave on it. The third Virtual-disk is t
Waiting for the destination Vsan to boot up as the converter helper serverIf you open the Console of the VM at this time, you can see the loading: Loading filesys ...Resolved under Windows:Upload the Converter-helper-vm.iso (32-bit) or Converter-helper-vm-x64.iso (64-bit) to the Datastore on the ESXi host. These two files are located in the following directory on the host where converter is installed:C:\Program Files (x86) \vmware\vmware VCenter Converter standalone\Note: 1, if the conversion 20
Waiting for the destination Vsan to boot up as the converter helper serverIf you open the Console of the VM at this time, you can see the loading: Loading filesys ...Resolved under Windows:Upload the Converter-helper-vm.iso (32-bit) or Converter-helper-vm-x64.iso (64-bit) to the Datastore on the ESXi host. These two files are located in the following directory on the host where converter is installed:C:\Program Files (x86) \vmware\vmware VCenter Converter standalone\Note: 1, if the conversion 20
"Data Recovery failure description"Company financial personnel for data maintenance, misoperation, in the financial software to initialize the data, because recently did not do backup, it caused a lot of financial documents lost.Because the financial data is very important, the customer is anxious to get back.The data Recovery Analysis "Engineer detection, in SQL Server database Enterprise Manager, discover what the
Vss write error prompt
An error is reported when converting the original physical machine in the project, prompting that the VSS writing program is incorrect. The solution is as follows:Cd/d % windir % \ system32Net stop vssNet stop swprvRegsvr32
The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion;
products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the
content of the page makes you feel confusing, please write us an email, we will handle the problem
within 5 days after receiving your email.
If you find any instances of plagiarism from the community, please send an email to:
info-contact@alibabacloud.com
and provide relevant evidence. A staff member will contact you within 5 working days.