qsfp transceiver

Want to know qsfp transceiver? we have a huge selection of qsfp transceiver information on alibabacloud.com

Simple troubleshooting of VLAN wireless Internet access switch faults

In the composition of wireless networks, the use of many devices deserves a detailed understanding. Today we will talk about the failure of VLAN wireless Internet access switches. The following is an experience shared by a netizen: A strange problem occurs in the VLAN of the two departments where an office area is located. Some websites on the Internet can be accessed normally, but some websites cannot; emails received through Outlook or Foxmail are normal, and small emails without attachments a

USB to UART bridging chip cp2101 and Its Application

Abstract:Cp2101 and its upgraded product cp2102 are highly integrated USB-UART bridging circuits manufactured by the United States's silicon company. They can use the simplest external circuit, the least external device and the smallest area of the circuit board for easy conversion from USB2.0 to UART. This paper introduces the main features and practical application methods of the circuit. Keywords:Cp2101 UART USB IntroductionCp2101 and its upgraded product cp2102 is the USB-UART Bridge Circui

15 MB per second! NXP promotes 2x2 MIMO WiMAX technology

NXP Semiconductors, formerly known as Philips semiconductor, has announced that the company uses a full range of transceiver products using WiMAX 2x2 MIMO (Multiple Input Multiple Output, Multiple inputs and Multiple outputs) technology, this series of products is specifically designed for mobile and handheld applications. To fully support the adoption of mobile WiMAX technology, the new series of NXP Semiconductors adopt 2x2 MIMO technology, doubling

Spartan6 series of articles: introduction and use of the gttransceiver

1. What is gttransceiver? The gttransceiver is a type of FPGA line speed up to 500 Mb/s. the 6 Gbit/s Transceiver can be flexibly configured using FPGA's internal programmable resources, making it suitable for different needs such as Ethernet and sata1.0 interfaces, it serves the physical layer of various high-speed serial interfaces. For the spartan6 series, the gtpa1_dual contains two GTS transceiver, or

[Important UPDATE] [Quartus II] [14.1 official Version]

languageDevelopment of FPGA tools for signal processing and scientific computing product development)Http://download.altera.com/akdlm/software/acdsinst/14.1/186/ib_installers/AOCLSetup-14.1.0.186-windows.exe 189MBHttp://download.altera.com/akdlm/software/acdsinst/14.1/186/ib_installers/aocl-rte-14.1.0.186-windows.exe 9MBDSP Builder (can not install, MATLAB plug-in, for signal processing product development)Http://download.altera.com/akdlm/software/acdsinst/14.1/186/ib_installers/DSPBuilderSetup

Test Integrated Wiring Optical Fiber Transmission Channel

The test of the optical cable cabling system is a necessary step for project acceptance. It is also the final process for the project contractor to honor the contract with the real estate owner. Only after the system test is passed can the cabling system be completed. The connectivity of devices is the most basic requirement for wiring system testing. The effectiveness of jumper systems can be easily tested. It is relatively difficult to test the indicator data of communication lines, generally,

Research and analysis on the data exchange between can and Ethernet

, but the price and interface card bottlenecks caused by the problem also exposed. This paper is based on SCM, can device and network chip as the core module to complete the function of the description. This approach lowers costs and avoids bottlenecks. 3. Hardware part There are a variety of hardware implementation, can use integrated TCP/IP protocol MCU plus can transceiver and controller, can also use integrated can controller MCU plus can

Solution for failure caused by switch frame sealing (1)

A strange problem occurs in the VLAN of the two Departments in the office area of the organization. Some websites on the Internet can access normally, but some websites cannot access it. emails received through Outlook or Foxmail are normal, it is also normal to send small emails without attachments, but it cannot be normally sent when sending large emails or emails containing attachments. Internet access is normal in other office areas of the Organization. The topology 1 of this part of the net

Some cisco switch modules

Some cisco switch modules organize the TwinGig Converter Module of the Catalyst 3750-E Series Switch: www.2cto.com TwinGig SFP converter can convert the 10 thousand M Ethernet X2 interface into two Gigabit Ethernet Small pluggable (SFP) ports. XENPAK uplink modules of Catalyst 3750G series switches: common optical modules of Ethernet switches include SFP, GBIC, XFP, and XENPAK, respectively: www.2cto.com SFP: Small Form-factor Pluggable transceiver, s

Production specifications and connection rules of twisted pair wires in the Network

, resulting in an increase in the error rate of signal transmission, this affects the overall network performance. Only by building standards can we ensure the normal operation of the network and facilitate the maintenance work in the future. Connection Methods between devices 1. network card and network cardWhen the 10 M and M NICs are directly connected, the cross-line connection method should be adopted. 2. Nic and optical transceiver moduleInstall

Cabling methods and strategies for twisted pair wires

lines within the line cannot be effectively eliminated, resulting in an increase in the error rate of signal transmission, this affects the overall network performance. Only by building standards can we ensure the normal operation of the network and facilitate the maintenance work in the future. Connection Methods between devices 1. network card and network card When the 10 M and M NICs are directly connected, no Hub is needed. Cross-line connection should be adopted. 2. Nic and optical

Cabling of various network cables in the Network

cannot be effectively eliminated, resulting in an increase in the error rate of signal transmission, this affects the overall network performance. Only by building standards can we ensure the normal operation of the network and facilitate the maintenance work in the future. Connection Methods between devices 1. network card and network card When the 10 M and M NICs are directly connected, no Hub is needed. Cross-line connection should be adopted. 2. Nic and optical

Twisted Pair wires have two Connection Methods: EIA/TIA 568b standard and EIA/TIA 568a standard. The specific method is as follows:

the line can be connected, but the interference between various lines within the line cannot be effectively eliminated, resulting in an increase in the error rate of signal transmission, this affects the overall network performance. Only by building standards can we ensure the normal operation of the network and facilitate the maintenance work in the future. Connection method between devices 1. When the network card is directly connected to the 10 m or M network card of the network card, the hu

SDH alarm Performance Analysis

1. Los: Alarm for signal lossIt indicates that the local end cannot receive light or electrical signals. When the signal amplitude remains below a preset threshold value (the threshold value is very small, far lower than or equal to 10-3) within a given time (for example, 100 ms, the SDH device enters the Los state. If two consecutive valid frame locating patterns are detected and no los is detected, the SDH device should exit the Los state.(1) optical port los:Network Management alarm: Light re

List of electronic engineering terms and definitions, in alphabetical order

ArticleDirectory Glossary: bare pad (exposed pad) Http://china.maxim-ic.com/glossary/definitions.mvp/terms/all :bare pad (exposed pad) Definition Some packages have bare pad to improve the heat dissipation of the device. It is usually not electrically insulated and can be grounded or powered according to electrical connection requirements. Synonym EP Bare chassis Keywords Pad, encapsulation, heat dissipation

Network cable-network cable Sequence

, and the other RJ45 crystal head is inserted. That is to say, the two ends have the opposite method, and the connected line will form two overlapping * shapes, otherwise it will not be connected. Then, insert the two ends of the prepared dual-gel cable into the NICS of the two computers.2. nic and optical transceiver module: Install the NIC on the computer and set it up. Connect the transceiver to the powe

Supports high-speed IrDA infrared controllers for Linux operating systems

Sigmatel introduces the high-speed IrDA infrared controller stir4220 and stir4210, which supports Macintosh software drivers and Linux operating systems. stir4220 is a fast infrared (vfir) controller with a speed of 16 Mbps, while stir4210 is a fast infrared (FIR) controller with a speed of 4 Mbps and stir4116 is a pin-compatible device, allows the manufacturer to create a USB high-speed adapter at different prices. Stir4210/4220 and stir4116 are low-power USB2.0 USB2.0 USB2.0 IrDA bridge co

Simple Troubleshooting VLAN Wireless internet switch

-port Gigabit Optical Module Ws-x6816-gbic, a 48-port fast switching module ws-x6548-rj-45). Trunk on the corresponding port of the 6509 and Annette Switch connected to the optical transceiver, the Annette switch is divided into two VLANs, respectively 172.25.6.0/24 (hereinafter referred to as VLAN6) and 172.25.7.0/24 (hereinafter referred to as VLAN7), The machines of the two departments are connected to their respective VLANs. The convergence layer

Ipdvd Supply CS Connector for 400G transmission

the socket, maximizing the density of the panel adapter, thereby increasing the cabling density.? Designed for QSFP-DD (200g/400g) applications, it is also suitable for applications such as OSFP (800G), so compatibility can be provided even in future higher-speed 800G transmissions.? It is suitable for use in more commonly used 1.25mm inserts, making them universal and without high cost risk.Currently, Ipdvd (Optec) is one of the few manufacturers th

GPU-accelerated high-performance computing for vehicle collision testing on the MG vehicle design platform

of 120 2 TB Hard DisksBare capacity: About 240 TB Ethernet Switch Ibm bnt g8052 Ethernet Switch-48 Gigabit Ports-40 thousand mb sfp + Port IB connection Cable 3 M copper FDR InfiniBand qsfp Cable FC optical fiber cable 5 m FC storage LC-LC optical fiber cable Display Cabinet 8-port KVM switch and rack-mounted folding LCD screen, IBM 42u standard cabinet, redundant PDU Power

Total Pages: 15 1 .... 5 6 7 8 9 .... 15 Go to: Go

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.