After the RDP function is added to the stm32f10x series of the cm3 core, RDP cannot be removed from the unsecured chip of the segger or the CMD of the unlock stm32, And the unlock stm32 prompts that the model cannot be recognized. After trying many methods, you still cannot remove RDP. It is estimated that the model is relatively new and segger is not fully supported yet. The
of the tutorial. ,5, more relevant content and considerations, see the tutorial can be. Featured Tutorials Download: Featured Tutorials Phase 6th: J-scope waveform software usage (bottom). pdf (1.34 MB) supporting examples (including MDK and IAR):STM32F103ZET6 Development Board: RTT mode for v4-j-scope waveform software. 7z (957.58 KB) STM32F407IGT6 Development Board: RTT mode for v5-j-scope waveform software. 7z (2.11 MB) STM32F429BIT6 Development Board: RTT mode for v6-j-scope waveform sof
standard text and command line interface with the target board. However, on many boards, the UART is used by the application.There is a semihosting (semi-managed), but it is very slow and depends on the debugger and Toolchain/library, plus the need to consume flash and RAM, so I don't recommend using semihosting under any circumstances."Note"semihosting is a mechanism for the ARM target machine, which can be based on the input / output request of the application code , Communicates with the hos
Keil upgrade to 4.72 version, Jlink began to prompt firmware upgrade, is very irritable, but look on the internet can be said to replace the previous version of the Segger file to Keil the latest version of the Segger file, it can be used, I tried the next, it really works ha, below to share the operation process.Save the previous 4.6 version of the Segger file,
Keil upgrade to 4.72 version, Jlink began to prompt firmware upgrade, is very irritable, but look on the internet can be said to replace the previous version of the Segger file to Keil the latest version of the Segger file, it can be used, I tried the next, it really works ha, below to share the operation process.
Save the previous 4.6 version of the Segger file
Label:J-link GDB Server-seggerHilden, Germany –september 15th, 2011–segger microcontroller today announced the freeAvailability of the J-link gdb-server. As the Gnu-tool-chain gains ground in terms of performance and usability, GDB continues to grow in popularity. Per the numerous requests of this expanding community, SEGGER are now offering their professionally developed gdb-server fo R free to all users o
plugin, with a link attached. Http://sourceforge.net/projects/gnuarmeclipse/also has an Eclipse plug-in for GDB debugging, called the zylin-embedded CDT. Download the URL below: HTTP://OPENSOURCE.ZYLIN.COM/ZYLINCDT In addition, is Jlink drive, which contains gdbserver, I use the version of V434a, is to buy other instructional video when attached. Segger official online seems to have not found this download link, you can Baidu, you can also download t
Long heard of ARM's various kinds of cool, but a look at that dense pin on the retreat, has been stuck in the single-chip computer level. This time I drew a piece of STM32 chip PCB board, want to learn a bit of their own.
Chip Model: STM32F103C8T6,CORTEX-M3 series, support ISP serial burning, support single-line debugging SWD and Jtag interface.
Package: LQFP48
Schematic diagram is as follows:
Design to consider two methods to write the program: first, the serial interface P4 TTL to USB direct
I'm tired of switching the system to download the u-boot.bin to the development board, I use Jlink, so I always want to make him in the UbuntuLinux environment can also use, when I browsed the Jlink official website, I found some clues. segger has a Linux test version of J-Link, but it is not easy to make Jlink run, after a lot of effort, I finally got some results. The following is a summary of my installation process and I will learn from you: 1. Do
Keil Download the program sometimes "The connected Emulor is a J-link clone" problem, which means that the identification of the jlink of piracy, should be a new version of the Jlink appear.
My method solves this problem by replacing the file. Replace the folder directly.
Replace the folder is E:\Program files\keil\arm path under the Segger file, replace the file link under, directly delete the original Segger
1, install J-link Drive.With the J-link driver in the KDS installation directory, enter the following directory (in my case):C:\Freescale\KDS_1.1.1\segger\USBDriverwill see the CDC, x64, x86 three folders, according to their own system to choose the corresponding program, only two steps (in my case):1> Enter the CDC folder, run Dpinst_x86.exe, and wait for the installation to complete.2> into the x86 folder, run DPInst.exe, and wait for the installati
and hold the control key, drag the control line directly to the target controller, and click the "Log on" button, it will automatically jump to the Controller PS on the right: After clicking a control, if you do not want to perform any processing during page Jump and want to jump to the next page, we recommend that you use the "Automatic segue" (manual mode): You need to manually execute the segue by writing code to complete the page Jump, as shown in: press and hold the control key to set an i
J-link with the cottage goods, do not know the cottage for a few generations of the kind .... With the stm32f103c8t6 of the small board is also a cottage for several generations of the kind, only 25 dollars ... Fortunately can use, J-link with Segger Company's software can identify, also can find the CPU, the board's feet are left out. Talk less, work.Connect the hardware, double-click Open Segger directory
the correct installation method2, again with wordy language vernacular I tread various pitsSecond, the installation method of Jlink drive on Linux2.1 . First, look at the version of Jlink you used in Keil on Windows (I assume you are turning from win!). )As follows:Found my keil5 in the Jlink version: 4.80g, the KEIL4 comes with the version is 4.60a2.2, then, from the Segger website to download the same version (near) version of the Jlink for Linux d
KEIL5 has been out for a long time, suddenly whim want to try it, then download the latest version from the official website. The installation process should be implemented by itself.
Here is a description of the problems encountered.
Hardware environment: Punctual Atom mini stm32 Development Board.
1. Prompt for firmware update when setting jlink debug option under Debug. Because the jlink in my hand is .... (everyone knows), dare not Point "is", fear of becoming a brick, dorm can not re-bru
;monitorwriteu320xe000ed0; note: among them, Monitorflashdevice required; runcommands text box fill in the following:; Monitorregr13= (0x0000000;mo
Monitor Endian LittleMonitor Speed 5Monitor ResetMonitor Sleep 100Monitor Speed autoMonitor Writeu32 0xe000ed08 = 0x00000000Note: The monitor flash device needs to modify itself according to its own STM32 device;In the Run commands text box, fill in the following:Monitor Reg R13 = (0x00000000)Monitor reg PC = (0x00000004)Break MainContinueNote:
This section describes how to burn bare-metal programs using Oflash and Openjtag. Oflash also supports parallel-burning writing, similar to Openjtag. If you want to use Jlink burn write, need to install Segger J-flash tools, here we do not introduce more.First, you need to install Oflash,oflash from the development board manufacturer or download from the Internet. Copy the Oflash to the "/usr/bin" directory by adding the executable permission . The co
under AxdSelect Config Target under Options, as shown in the following image:Click the Add button to add JlinkRDI.dll (make sure you have installed the driver provided by Segger Company, this note installs 3.80a), as shown in the following figure:
After the addition is complete, the following illustration shows:
2, Configuration JlinkThen, after adding the finished, click Configure, the Jlink Settings dialog box appears, we mainly choose the process
The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion;
products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the
content of the page makes you feel confusing, please write us an email, we will handle the problem
within 5 days after receiving your email.
If you find any instances of plagiarism from the community, please send an email to:
info-contact@alibabacloud.com
and provide relevant evidence. A staff member will contact you within 5 working days.