AutoNumber ID of the last inserted recordone of the most recent problems in developing a project is getting its own ID in the database immediately after inserting a record in order to process the associated data. There are several ways in which you can do this in SQL Server 2000. Please see the following explanations and comparisons in detail.
The easiest way to get this ID is to: (Here's a simple and pra
The first step: Open your "Start menu", open "program"-SQL Server Enterprise Mananger "Enterprise Manager"In the SQL database you want to export, right-click menu: All Tasks-"Export data"
Step Two: An Export wizard window will appear.Select the exported data source, for the database you have just chosen, if found does not correspond to its own modification.
Step three: Go to the choice of exporting to
If you want to redefine the serial number that is automatically generated and stored in the column when you add a new record to the table, you can change the identity property of the column. You can set the identity property of only one column in each table.A column with identity attributes contains system-generated contiguous values that uniquely identify each row in the table (for example, employee identification numbers). When you insert a value in a table that contains an identity column, Mi
This is often the problem with SQL Server:
After a table has an AutoNumber column, the number of automatic numbers has been accumulated tens of thousands, since testing a lot of data. Now it is time to use this table, the test data has been deleted, the remaining problem is in the entry of new data, numbering will only continue to increase, has been used but deleted numbers can not be used, who knows how to
Tags: data div sp c SQL res table BS r1. TRUNCATE TABLE TableName2. The DBCC checkident (tablename,reseed,1) Truncate command not only clears all data, but also restores the value of the identity's seed to its original value.DBCC CHECKIDENT is more convenient, and you can specify the value of seed without deleting the data. DBCC checkident Just moves the index number of the auto-orchestration to the location you specified, but the actual number does n
Summary of common basic points are as follows:
1, there are two types of triggers: data definition language triggers (DDL triggers) and data manipulation language triggers (DML triggers).
DDL triggers: A response that occurs when a user modifies a database structure by performing a data definition (CREATE, ALTER, drop, or similar statement) to the database.
DML triggers: Occurs when a user performs a data operation on the database, and the code in the trigger is invoked automatically.
2. DML tri
Method One:
Delete the Automatically numbered field, and then build the same AutoNumber field.
Method Two:
Automatic numbering is always increased (plus 1 each time), you add a record of its number will be in front of the base plus 1 (delete also count), if you number 1 is deleted, you want to start from 1, you can open the Access database, select Tools, and then select Database Utilities, Click the Compress and Repair database, so that's OK.
Method
In actual operation, the demand of the serial number is very big. For example, we often hope that the order number or the order number of products in order to automatically increment the sequential numbers without the need for manual input, when you encounter such requirements, do not want to be impulsive and to solve the program code, because as long as the use of automatic Number field, all the way!
Ado. NET does not provide additional, so-called AutoNumb
identification numbers. To avoid this phenomenon it is best to set the automatic number as the primary key, or not to repeat. Please realize this Jet won ' t prevent you to altering AutoNumber seed and increment values that produce values . However, if the AutoNumber column has been designated as the primary key or it contains a unique index, you'll be Preven Ted from saving rows with duplicates. However,
How do I get the primary key value AutoNumber for the insert data after the MySQL tutorial insert statement?
The method is very simple, the MySQL data with the mysql_insert_id ();
How to use:
Insert INTO (a ') VALUES (' B ')
$nid = mysql_insert_id ();
Method Two:
LAST_INSERT_ID (), but there is a lot of difference about this function compared to mysql_insert_id (), mysql_insert_id () is the insert_id that gets the current session directly, and l
access| Database
The following code is the simplest example code that uses ASP to create an Access table, and the ID number that is created is an AutoNumber number.
Dim
ConnDim
DBPathSet Conn=server.createobject ("Adodb.connection"
)Dbpath=server.mappath ("Data/data.mdb"
)Conn. Open driver={microsoft Access Driver (*.mdb)};d bq= "
DBPathdmlsql= "Create table Table1 (ID autoincrement (1,1) primary key, Zhengshu int, wenzi text)"
Conn.exe
The Change field AutoNumber type appears in Access and cannot be changed back! (Resolved)
Once you have changed the self-added field in access to a numeric value, and then you change back to self-increase, you are prompted: After you have entered data in the table, you cannot change any field data type to AutoNumber errors, and resolve:
1, the first right key table, design, open the field design state.
2
yesterday accidentally found an Access database automatic numbering initialization of a method, the Internet is said to use Excel to rearrange the import or compression and repair database, I think this is misleading everyone. Here I share a new method that I have proven in practice. When you open the Access database, open the table, menu-View-Design view, move the cursor to the field of ID (AutoNumber), and then right-click to select the Delete row,
The current popular database provides automatic numbering type, SQLite is no exception. When an AutoNumber field is included in the database, SQLite automatically creates a table named Sqlite_sequence. This table contains two fields: Name and seq. The Name field records the table in which the AutoNumber field is located, and the SEQ Field records the currently used ordinal (the next record is the current or
The Change field "AutoNumber" type appears in Access and cannot be changed back! (Resolved)Once you have changed the self-increment field in access to a numeric value and then changed back to self-increment, tip: After you enter data in the table, you cannot change any of the field data types to "AutoNumber" errors, the workaround:1, right-click the table, design, open the field design status.2. Remove the
Insert a table in Word, we usually add a number to the table, so how to quickly number it, this tutorial will introduce you to the automatic numbering method.
Operation Steps
1, open Word2010, select "Draw Table" in the "Insert" function bar, and then draw a good table.
2. Then position the mouse in the first cell, and select the Numbered Library button in the paragraph group in the Start function bar.
3, and then select the format brush in the Clipboard. Then drag down the lef
As the following figure is a Word table, now we want to produce a sequence number from the second cell in the first column.
First, as in the following figure, select the cells that you want to produce an ordinal number.
Next, perform
First, positive sequence
A, Allowpaging=false case
can be achieved
But the more interesting approach is to use this method
Some people may find it strange why items.count is like this, not all the sum. But it's easy to
DataGrid in the ASPX file:
//=============================================================================
ItemDataBound event in the DataGrid of the. aspx.cs file:
private void Datagrid1_itemdatabound (object sender,
Word auto numbering is a very useful little feature in office that is helpful when writing a paper
Tools/raw Materials
Office Word 2010 Software
Method/Step
We have a list of meeting names, and you can see that the Red Arrows in the
The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion;
products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the
content of the page makes you feel confusing, please write us an email, we will handle the problem
within 5 days after receiving your email.
If you find any instances of plagiarism from the community, please send an email to:
info-contact@alibabacloud.com
and provide relevant evidence. A staff member will contact you within 5 working days.