unpack ..., select the folder where the split file is stored.After the disassembly, there are four files, which can be opened and viewed individually.A Transact-SQL script that contains the statements for creating the objects defined in the DAC.4,register DACCreating an empty db,db on the target instance does not necessarily have the same name as the extract db, the empty db created here is Dac_test, click Task->register as Data-tier application ...,
The DAC function should be to call C:\Program Files\Microsoft SQL under this path server\100\sdk\assemblies\microsoft.sqlserver.management.dac.dll With Ilspy This tool to decompile, in fact sqlsrver many functional components are written in. Net Unless some of the core functional components are in C + + or C, you will find that many DLLs can be ilspy with this. NET Decompile tool for anti-compilation The microemulsion does not confuse their code, and
Server 2005 Dedicated Administrator connection (DAC) tips for using
1 What is a dedicated administrator connection?
SQL Server 2005 provides an administrator with a special diagnostic connection for use when it is not possible to establish a standard connection with the server.
2 What is the use of a dedicated administrator connection?
Even when SQL Server does not respond to standard connection requests, administrators can use this connection t
Turn: http://www.cnblogs.com/kerrycode/archive/2010/09/18/1830071.html
SQL Server provides a dedicated administrator Link (DAC ). DAC allows administrators to access the running server to execute diagnostic functions or transact-SQL statements, or to troubleshoot problems on the server, even if the server is locked or runs abnormally.
DAC can only be used on th
The STM32 DAC module ( digital/Analog Conversion module ) is a 12-bit digital input, voltage-output DAC. The DAC can be configured in either 8-bit or 12-bit mode, or it can be used with a DMA controller. When the DAC is operating in 12-bit mode, the data can be left-justified or right-aligned. The
SQL Server 2005 Dedicated Administrator connection (DAC) tips for using
1 What is a dedicated administrator connection?SQL Server 2005 provides an administrator with a special diagnostic connection for use when it is not possible to establish a standard connection with the server.
2 What is the use of a dedicated administrator connection?Even when SQL Server does not respond to standard connection requests, administrators can use this connection
Tags: style class code color int StrongReference: http://technet.microsoft.com/zh-cn/library/ms178068 (v=sql.105). aspxProblem:A DBA who interned in our company asked me how to turn on the DAC for SQL Server 2008. At first I wanted to tell him directly, but the wiser option was to share the document options. This article will tell you how to open a DAC in SQL Server 2008.Solution:Microsoft added the new
Stm32f103 DAC study notes
Recently, I am working on the current-type signal output project and encountered some problems. Here I will take a note of these solutions for future use. This part of the Manual is not detailed, so we also encountered some resistance in use.
A 64-core package is used. The reference vref + of this core ADC is the same port as the power supply, and vref-shares the power supply location. When the Active Value of the battery
In some cases, for example, if you want to use DAC to output a sine wave, the simplest idea is to use a Timer for an interruption and assign a new value to the DAC during the interruption, and the DAC conversion is triggered. In this way, there will be some drawbacks. For example, in a complex system, there will be many interruptions, and Timer's interruption pri
few microcontrollers include a DAC. Although you can easily find a inexpensive DAC to control from your microcontroller, you can use, unused peripherals inste Ad of adding parts. Fortunately, you can convert a microcontroller ' s ADC channel along with a GPIO (general-purpose input/output) pin to a D AC. You can make a DAC by charging a capacitor to an analog lev
The channel of the DAC module outputs an analog voltage with the following detailed setup steps:1) Turn on the PA port clock and set the PA4 as analog input.Stm32f103zet6 DAC Channel 1 is connected to the PA4, so we first want to enable the Porta clock, and then set the PA4 as the analog input (although the input, but the STM32 inside will be connected to the DAC
Tags: Exchange DAC cross-site DagData Center activation Coordination Mode also known as DAC mode, this mode should be enabled for Dags with two or more nodes that use continuous replication . This mode controls the startup database mount behavior of the DAG, which prevents network partition failures at the database level during data center recovery. For example, the primary datacenter loses power, all repli
waveforms to occurShielding, amplitude settingDAC1 output cache on "Improve port drive capability!" 】Initializing the DAC Channel 1Enable to DAC1Setting the DAC value4) Repeated modification of the value call is only called with the following 2 lines of codeDac_setchannel1data (Dac_align_12b_r, Value);Dac_softwaretriggercmd (Dac_channel_1, ENABLE);
2. Code: PA4 Port output = 3000/4095 * Vref voltage#
Label:1. Preparation The informatic Client must be installed before installing the DAC; dac11g client must be installed on a single machine with the Informatica client; Install Java version 1.6 and above on dac11g server; dac11g server must be installed on a single machine with Informatica server; when the installation is complete, the DAC directory contains the control files for the dac11g Server and the d
Source: http://www.cnblogs.com/lyhabc/archive/2012/09/23/2698702.htmlDAC: dedicated Admin ConnectionWhen SQL Server is unable to establish a database connection due to insufficient system resources or other exceptions, you can use the system-reserved DAC to connect to the database for troubleshooting and troubleshooting. A DAC can use only limited resources. Do not use a
After the release of DAC4, some modifications were made, mainly by modifying some bugs, with few new functions and no release. Yesterday, a Command configuration file was added and several functions were merged, today we released version 4.2:
* Added support for jqGrid.* Add the Command configuration file.* Adds expression is null and is not null.
: Http://dac.codeplex.com/releases/view/91736
I have been using NuGet to obtain common components, which is very convenient. I also want to packa
The DAC (administrator-specific connection) is required when decrypting a stored procedure that is already encrypted. When an error occurs while connecting to the DAC, the following steps are described:
1. The following error occurred while connecting the DAC:
C:/> sqlcmd-a-S 10.0.0.211-u sa-p zxyz
HResult 0xFFFFFFFF, Level 16, State 1
SQL Network interface: An e
These two days reviewed the DAC,DMA plus put the basic timer TIM6 and TIM7 looked, intends to write a comprehensive point of the program,, on the internet to find some about the DAC,DMA and timer related procedures, the final intention to write the output sine Wave program ...Because there is no oscilloscope, it will not show the effect, it is intended to use software debugging to see the effect, but TIM6 a
STM32 F4 DAC DMA waveform GeneratorGoal: generating an arbitrary periodic waveform using a DACS with DMA and TIM6 as a trigger.Agenda:
Modeling a waveform in MATLAB and getting the waveform data
Studying the DAC, DMA, and TIM6 to see how it can is used to generate a waveform
Coding and testing a couple of functions
Percent generating an Nbit sine wave%modifiable Parameters
Tags: admin DAC remote admin connectionsSQL Server dedicated Administrator connection (dedicated admin Connection (DAC))Only members of the SQL Server sysadmin role can use a DAC connection. By default, connections can only be established from clients running on the server.Open SSMs, in the Connect to Server window, select Cancel, and then select the File menu, d
The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion;
products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the
content of the page makes you feel confusing, please write us an email, we will handle the problem
within 5 days after receiving your email.
If you find any instances of plagiarism from the community, please send an email to:
info-contact@alibabacloud.com
and provide relevant evidence. A staff member will contact you within 5 working days.