Reason of slow LAN network speed

Computer network failure is unavoidable. Network fault diagnosis is an important work of network management. Generally when the network occurs information is not available, can not browse the Web, and other connectivity failures, the phenomenon is relatively clear, easy to observe and locate the fault point, such a fault is not difficult to solve. But the most troubling thing is that the internet is a pass, but the network speed slows down.When faced with this kind of "soft" fault for the first

What's wrong with LAN getting slower

Fault analysis of local area network speed slow de In many network failures, the most vexing is that the network is pass, but the speed is slow. The first face of this kind of "soft" failure, often some people will be helpless, this article for you to cause such "soft" fault common causes and elimination methods, improve the ability to deal with practical problems. 1, network cable problem We know that twisted pair is made by 4 pairs of lines strictly and reasonably tightly twisted together t

Common wiring system faults and troubleshooting Technology

that can precisely locate near-end crosstalk and does not have a dead zone.We will provide a detailed description of Common Faults in field testing combined with the above Testing Technology:1. line chart (Wire Map) Error-- It mainly includes the following error types: reverse join, error pair, and string bypass. For the first two kinds of errors, the general test equipment can be easily found, the test technology is also very simple, but it is difficult to find the string around. The error occ

Extended 6-class UTP patch cord for the enhanced series launched by Simon

flexibility of the patch cord from the distribution frame or device to the cable manager. This allows the jumper to maintain excellent external crosstalk performance while maintaining the same bending radius and cabling flexibility as the non-reinforced jumper. 10G 6A UTP BladePatch is a unique RJ45 patch cord that is pluggable without pressing down an external lock. Patented push-pull internal lock structure. When the plug is inserted into the socket or distribution frame, it is positioned and

Dual-router dual-small switch sets up the company's network, two public IP Access Cases

; mFirst, make sure that the network environment of A and B has been set up, that is, the ADSL line is connected to the ADSL cat, the cat is connected to the router, the router is connected to the switch, and the switch is connected to each terminal. Make sure that the local networks of A and B are shared successfully and can access the Internet. (It should be noted that it is better not to directly connect to the terminal on the vro. It is not stable after it is connected. In fact, I will conne

Methods and strategies of twisted pair wires in the Network

two types: shielded and unshielded. If it is used outdoors, The Screen Shield is better. Generally, it is enough to use non-shielded five-category cables in the room. Because no Screen Shield is provided, the cables are relatively soft, but their connection methods are the same. In general, there are four pairs of lines twisted together in the cat5e category and marked with different colors. Figure 1 Twisted Pair wires have two Connection Methods: EIA/TIA 568B standard and EIA/TIA 568A sta

Cabling and installation are increasingly easy to view the next generation of cabling systems

Positioning Technology (CFPM) of the SYSTIMAX lab plug-in, and reduces the cross-module effect by combining the system level tools, achieving a fast and reliable connection design. The XG system shielding SL module launched by Tyco electronic AMP uses 360. The module adopts a metal shielding shell for overall shielding. It is easy to install and can effectively ensure the good connection between the cable shielding layer and the module shielding layer. The slim shape is compatible with the SL s

Failure Analysis of twisted pair cabling with non-abrupt View Details

"disconnected. Many users often use a one-to-one error connection method in cabling. When the connection distance is short, the system will not encounter connection faults. However, when the connection distance is long, the network is busy or high-speed, it is easy ......, The core is to make the 3 and 6 pins the same twisted pair (based on the T568A or T568B standard ). The distance between a user server

Application viewpoint: NETCORE router FAQs

lanport status indicator shows no normal connection. (2 ). the lanport Status Indicator corresponding to the ethernet card connection of the router is normal), but the 2505nr cannot be managed through this port, this type of fault is roughly divided into two major connection/configuration error types. A. The status indicator of the NETCORE router lan interface corresponding to the physical connection error is abnormal) Solution: 1) check whether the network cable is strictly compliant with the

Causes and solutions for slow speed of LAN

Faults in computer networks are inevitable. Network fault diagnosis is an important task in network management. Generally, when the network encounters a connectivity fault such as information failure and cannot browse the Web, the fault phenomenon is clear and easy to observe and locate the fault point. It is not difficult to solve such a fault. However, the biggest headache is that the network is accessible, but the network speed slows down. When faced with such "soft" faults for the first time

CCNA Theoretical knowledge loopholes

authentication methods are available?does not validatePassword verificationLocal user name + password Authentication AAA server Authentication21) Write the 568A and 568B standard line sequence of twisted pair (network cable). T568A: Green white green orange white blue blue white orange brown white brown t568b: orange white orange green white blue blue white green brown white Brown 23) What two types of opt

Dipper -- Common wiring faults in IDC room wiring cracking (1)

"connected" but "disconnected. Many users often use a one-to-one error connection method in cabling. When the connection distance is short, the system will not encounter connection faults. However, when the connection distance is long, the network is busy or high-speed, it is easy ......, The core is to make the 3 and 6 pins the same twisted pair (based on the T568A or T568B standard ). In Ethernet, two pa

Reason analysis of slow speed

First, the network itself problem The destination Web site you want to connect to is on a server with insufficient bandwidth or too much load. The processing method is very simple, please change the time period to go up again or change a target website. Second, network cable problems caused by slow speed We know that twisted-pair wires are tightly twisted and together by four pairs of lines to reduce crosstalk and background noise. At the same time, only 1, 2 and 3, 64 lines of twisted pair a

Rules for making cable

twisted-pair and six-type twisted-pair line. Maximum bandwidth of up to 1000Mbps. Twisted pair of the only drawback is that the transmission distance is shorter, can only reach 100 meters, so in the wiring, if the use of star topology structure, covering the range can only reach 200*200 meters. 1000M network card data transmission is two-way, need to use four pairs of lines, that is 8 core wire. 100M below, generally use 1, 2, 3, 6, four root line. According to the standard is orange, green a

Seven problems to speed up the computer speed

together by four pairs of lines to reduce crosstalk and background noise. At the same time, only 1, 2 and 3, 64 lines of twisted pair are used in the T568A standard and the T568B standard, where 1, 2 are used for sending, 3, 6 is used for reception, and 1, 2 must come from a winding pair, 3, 6 must come from a revolve pair. Only in this way can the maximum avoid crosstalk and ensure data transmission. Not

Network connection is normal, network speed is fast and slow

The following are the reasons and solutions for the slow speed of the network: First, the network itself problem The destination Web site you want to connect to is on a server with insufficient bandwidth or too much load. The processing method is very simple, please change the time period to go up again or change a target website. Second, network cable problems caused by slow speed We know that twisted-pair wires are tightly twisted and together by four pairs of lines to reduce crosstalk and

Common solutions for slow network speeds

The following are the problems that lead to slow network, as well as some common network problems to solve, in this collation to the users. (Internet collection) First, the network itself problem The destination Web site you want to connect to is on a server with insufficient bandwidth or too much load. The processing method is very simple, please change the time period to go up again or change a target website. Second, network cable problems caused by slow speed We know that twisted

How to make the Wire crystal head?

practice is not the same, one end tia/eia-568b standard, one end tia/eia-568a standard. Used for: PC network card to PC network card, hub ordinary mouth to hub ordinary mouth. Cross line: How to determine the use of straight or crossed lines: Same device port: Cross line, different device port: Straight line. The maximum transmission distance of twisted pair cable is 100m. If you want to increase the transmission distance, the two-strand cable can be installed between the repea

What is RJ45

RJ45 the definition and standards of the relevant provisions.    RJ45 is a commonly used name, referring to the standardization of IEC (60) 603-7, using a modular jack or plug of 8 locations (8 pins) defined by the International connectors Standard. IEC (60) 603-7 is also the ISO/IEC 11801 International General cabling Standard Connection hardware reference standard.    ISO/IEC 11801 standards regarding the requirements for connecting hardware:    • The physical dimensions of the information

Common causes of network "soft fault" and its elimination method

Computer network failure is unavoidable. Network fault diagnosis is an important work of network management. Generally when the network occurs information is not available, can not browse the Web, and other connectivity failures, the phenomenon is relatively clear, easy to observe and locate the fault point, such a fault is not difficult to solve. But the most troubling thing is that the internet is a pass, but the network speed slows down. When confronted with such "soft faults" for the first

Total Pages: 4 1 2 3 4 Go to: Go

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.