Shut down the "virtual machine" in the VSphere client.
Remove your virtual machine from the ESXi inventory.
Browse your Datastore and find the virtual machine s. vmx file. Download it to your desktop.
Open the. vmx file in Notepad or your favorite text editor.
Find the following line (usually line 3) in your configuration and the "ten" to a "9"Virtualhw.version = "Ten" would become virtualhw.version = "9"
Save the file and overwrite your existing. vmx file.
Upload the file to t
in MySQL5.7Create a tableCreate Table User int auto_increment,data JSON,primarykey(UID));Building dataInsert into User Values (NULL,'{' "name": "Wang", "Address": "Shenyang"}'); Insert into User Values (NULL,'{' "name": "Zhao", "Address": "Riben"}');Build a virtual column of namesAlter Table User Add user_name varchar ( $.name');Build IndexAlter Table User Add index idx_name (user_name);InquireSelect * from User where user_name = ' "Wang" ';Query analysis (explain ... \g)You can see that the
, and then adding 13 virtual CPUs to the virtual machine to reach a total of 17 virtual CPUs, how does Numa equalize? is technically possible, but unless the VM resides on a physical machine that has a larger number of CPU sockets than the physical CPU core, it can cause performance degradation across NUMA due to memory addressing. Therefore, the Vnuma extension is not enabled, regardless of whether you enable any form of hot-add CPU or hot-add memory. And you are likely to affect existing SQL S
is required.650) this.width=650; "style=" Width:auto;height:auto; "src=" http://mmbiz.qpic.cn/mmbiz/ orl2fuhmgzcd7lflfw2i9h4k4qcggvzz9ulhsryarxgaamltkw6f8xib7oquqlft1ahrlbmelqf4dm9ckzupxq/640?wx_fmt=png Wxfrom=5wx_lazy=1 "alt=" 640?wx_fmt=pngwxfrom=5wx_lazy=1 "/>The storage virtual machine and compute virtual machine isolation mechanism enable Nutanix to support different virtualization platforms, such as VMware, KVM, and Hyper-V, unlike VMware Vsan,
ENABLE_SSD User step three: Reclaim re- The following:[[Email protected]:~] ESXCLI Storage core claiming reclaim-d mpx.vmhba1:C0:T1:L0 Fourth Step: Verify the success of the modification, in Ssd:true, indicating that the modification was successful. Re-scan the disk to start the Vsan experiment.[[Email protected]:~] ESXCLI Storage Core device list-d mpx.vmhba1:C0:T1:L0 Mpx.vmhba1:C0:T1:L0Display name:local VMware Disk (mpx.vmhba1:C0:T1:L0)Has settabl
9148 Common configuration of fiber switchesSwitch Basic configuration1. Configure the switch nameswitch# Config TerminelSwitch (config) # switchname SwitchA2. Configure the management IP address of the switchSwitch (config) #Switch (config) # interface Mgmt 0Switch (config-if) # IP adress 192.168.100.10 255.255.255.0Switch (config-if) # no shutdownInterface Mgmt 0 represents the management port of the switch.3. Configure the default gatewaySwitch (config) # IP default-gateway 192.168.100.14. Cha
depending on the support and features of the virtual hard disk device. Most of the information displayed (for example, the virtual disk file path for virtual disk file alternatives) is read-only, because the virtual hard disk device can be changed only if it is removed and re-added. Even if the virtual machine is running, you can add the disk and add more space to the existing disk. If the disk is backed up by a normal vdisk file:
The disk mode control can be used to make advanced con
Tags: cloud Virtualization"VMware VSphere 6.5 Enterprise Operations" has been published by the People's post and telecommunications press, buy Link: https://item.jd.com/26391828617.htmlThis book, based on vsphere 6.5.0, describes the content of VMware vsphere Enterprise operations, including the building of traditional vsphere data centers, implementation planning for Vsan datacenters, backup and recovery of virtual machines, migration from existing p
, so it will not affect the continuous deployment of the isolated SAN.
Although these independent storage networks help to ensure performance and reduce network-level interference, their implementation is expensive. They not only need to be configured with switches, but also increase management complexity. In addition, this method also wastes ports and increases the customer's financial burden. To solve these problems, Cisco uses virtual SANVSAN to completely change the storage network deploymen
When installing Redis Desktop Manager, I see the failed to connect to chromium.googlesource.com Port 443:connection timed out error, as described in the end.
WorkaroundThis problem occurs for some reason that you cannot connect to Google, so that git can be resolved by proxy.How to set up a git proxy, you can see http://www.cnblogs.com/zhuxiaoxi/p/8398475.html? ~ Yaourt redis-desktop-manager1 Aur/redis-desktop-manager 0.9.0_alpha5-1 (0.00) Open Source Cross-platform Redis D Esktop Manager b
First item: Create a disk bare map.RDM (RAM Device Mapping) is a way for a virtual machine to use a physical disk directly through a map. VMware RDM is only for Sans (note: Map local disks are not provided).RDM is a file on a VMFS volume that is like a proxy or medium to the original physical device. We can think of RDM as a symbolic chain to the original LUN. Th
Cisco mds9222i Fibre Switch most commonly used debug commands1. Check the switch portShow interface [Interface-range]View specified port run status, WWN information, configuration parameters, and packet statistics.Demonstration:mds9222i-1# Show Interface FC1/1FC1/1 is trunking-port FC1/1 operating normally, is a TE portHardware is Fibre Channel, SFP was short wave laser w/o OFC (SN)-Port, SFP hardware informationPort WWN is 20:01:00:05:73:ad:2a:00-switch port WWNPeer Port WWN is 20:01:00:05:73:a
Project implementation: Install the configuration of the virtualized environment, and management.(3) VMware virtualization operations, to solve the problems encountered by transport dimension. (4) After 5-6 years of project operation, the enterprise is upgraded and reformed.
Content module
Course Name
Lessons and knowledge points
Length of study
Expected to achieve effect
Planning design and product selection of vsphere Virtualization Data Center for SME
ESXi command line:Vim-cmd Vmsvc/getallvms |grep Vim-cmd vmsvc/power.getstate Vim-cmd vmsvc/power.on Vim-cmd/hostsvc/hostsummary | grep Inmaintenancemode to see if maintenance mode is enteredVim-cmd/hostsvc/maintenance_mode_enter Entering maintenance modeESXCLI VM Process List # Displays only the virtual machines that are powered onESXCLI VM process Kill--type=[soft,hard,force]--world-id=worldnumber deleting a virtual machine/ETC/INIT.D/VPXA Status View vcenter agent operating conditionVsan comma
Link: Compiling MacOS version of Redisdesktopmmanager latest versionCompiling the latest version of the Redisdesktopmmanager version of MacOSDownload source code??clone --recursive https://github.com/uglide/RedisDesktopManager.git -b 0.9 rdm cd ./rdm Environment configuration?
Install XCode with Xcode build tools
Install Homebrew
Build RDM Depen
Tags: Cisco MDS zone san Configure a Cisco MDS Optical Fiber storage switch (MDS multilayer Director Switch multi-layer optical fiber array switch)General process: 1: Create a vsan, add the port to vsan2: create a zone, add the port to zone3: Create a zoneset, add the zone to the set, and enable zoneset4: Enable all ports Use command line basic configuration MDS-1 (config) # switchname MDS-1 MDS-1 (config) # IP default-Gateway 66.66.3.254 MDS-1 (
//
// graphic verification code generation page
/// Abraxas@163.com
// reference method:
(n is the number of digits of the Verification Code)
//
using system; using system. collections; using system. componentmodel; using system. data; using system. drawing; using system. web; using system. web. sessionstate; using system. web. ui; using system. web. UI. webcontrols; using system. web. UI. htmlcontrols; using system. io;
namespace Abraxas { //
machines to new servers. This design makes it possible to worry about the Secure Isolation of disks mapped to RDM on bare devices. If more than two partitions are defined, You need to reset the network. To solve this problem, the virtual HBA port (VPort) is displayed. The VPort uses the N port ID (NPIV) Protocol to enable the virtual server administrator to bind the virtual machine to the storage resources, the VPort parameter is used to define multi
Build more things, poor performance of the computer compiled for a long time.: Https://redisdesktop.com/downloadOriginally wanted to download one, but found that only Windows is free, but the official website provides a build from source guidelines, then build one directly.The first is to obtain the sourcegit clone--recursive https://github.com/uglide/RedisDesktopManager.git-b 0.9 rdm CD./RDM Build Step:1
It's really hard to install Redis Desktop Manager under Ubuntu, and you can put it on by the following method. No, it's not hard.
Method 1,
git clone--recursive https://github.com/uglide/RedisDesktopManager.git-b 0.9 rdm CD./RDM
CD src/./configuresource/opt/qt59/bin/qt59-env.sh qmake make sudo make installCd/usr/share/redis-desktop-manager/binsudo mv qt.conf qt.backupMethod 2,
Download tar.gz file
Dow
The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion;
products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the
content of the page makes you feel confusing, please write us an email, we will handle the problem
within 5 days after receiving your email.
If you find any instances of plagiarism from the community, please send an email to:
info-contact@alibabacloud.com
and provide relevant evidence. A staff member will contact you within 5 working days.