DELL R710 Error code Rollup

Source: Internet
Author: User
Tags dell r710

The server is a R710 common error rollup:


Error:

E1422 CPU 1 Machine Check error. Power Cycle AC


Solution:

The system BIOS has reported a machine check error. Disconnect the system from AC power for 10 seconds, and then restart the system


Attached: DELL_LCD Error Prompt code

Code text Reason
E1000 Failsafe voltage error. Contact Support. (Fault protection voltage error.) Please contact your support staff. Review the system event logs for critical failure events.
E1114 Ambient Temp exceeds allowed range. (ambient temperature exceeds the permitted range.) Ambient temperature to a point beyond the permitted range.
E1116 Memory Disabled, temp above range. Power cycle AC. (Memory is disabled and temperature is out of range.) Please turn off AC power and turn it on. The memory has exceeded the license temperature and the system has disabled it to prevent component damage.
E1210 motherboard battery failure. Check battery. (motherboard battery failure.) Please check the battery. ) The CMOS battery is missing, or the voltage exceeds the permissible range.
E1211 RAID Controller battery failure. Check Battery. (RAID controller battery failure.) Please check the battery. The RAID battery is lost, damaged, or unable to recharge due to temperature problems.
E1216 3.3V regulator failure. Reseat PCIe cards. (3.3V regulator failure.) Please reset the PCIe card. ) The 3.3V voltage regulator is faulted.
E1229 CPU # VCORE regulator failure. Reseat CPU. (CPU # VCORE voltage regulator failure. Please reset the CPU. ) a specific processor VCORE voltage regulator fails.
E122A CPU # VTT regulator failure. Reseat CPU. (CPU # VTT voltage regulator failure. Please reset the CPU. ) a specific processor VTT voltage regulator fails.
e122c CPU Power Fault. Power Cycle AC. (CPU power failure.) Please turn off AC power and turn it on. A power failure was detected while powering on the processor.
e122d Memory Regulator # Failed. Reseat DIMMs. (Memory regulator # failure. Please reset the DIMM. ) A memory regulator fails.
E122E on-board regulator failed. Call support. (Airborne voltage regulator failure.) Please contact your support staff. A built-in regulator fails.
E1310 Fan # # RPM exceeding range. Check fan. (Fan # # RPM is out of range. Please check the fan. The number of RPM per minute for a particular fan exceeds the expected operating range.
E1311 Fan Module # # RPM exceeding range. Check fan. (Fan Module # # RPM is out of range. Please check the fan. The number of RPM per minute for a particular fan in a particular module exceeds the expected operating range.
E1313 Fan redundancy lost. Check fans. (Fan redundancy is lost.) Please check the fan. ) The fan in the system is no longer redundant. If there is a fan failure again, the system will be in danger of overheating.
E1410 system Fatal Error detected. (A systematic critical error has been detected.) ) detected a serious system error.
E1414 CPU # Temp exceeding range. Check CPU heatsink. (CPU # temperature out of range. Please check the CPU heatsink. A specific processor has exceeded the acceptable temperature range.
E1418 CPU # not detected. Check CPU is seated properly. (CPU not detected #. Please check that the CPU is seated correctly. The specified processor is missing or damaged and the system configuration is not supported.
e141c unsupported CPU configur-ation. Check CPU or BIOS revision. (CPU configuration is not supported.) Please check the CPU or BIOS version. Does not support the configuration of the processor
e141f CPU # protocol error. Power cycle AC. (CPU # protocol error. Please turn off AC power and turn it on. The system BIOS has reported a processor protocol error.
E1420 CPU Bus parity error. Power cycle AC. (CPU bus parity error.) Please turn off AC power and turn it on. The system BIOS has reported a processor bus parity error.
E1422 CPU # Machine Check error. Power cycle AC. (CPU # Machine Check error. Please turn off AC power and turn it on. The system BIOS has reported a machine check error.
E1610 Power Supply # (# # # W) missing. Check power supply. (Power Device # (# # # W) is missing. Please check the power supply device. The specific power device is removed, or the system is missing the device.
E1614 Power Supply # (# # # W) error. Check power supply. (Power Device # (# # # W) error. Please check the power supply device. ) A specific power supply device fails.
E1618 predictive Failure on Power Supply # (# # # W). Check PSU. (Power Device # (# # # W) A predictive failure occurred. Please check the PSU. ) A power supply fan failure, too high temperature, or a power communication error caused an impending power failure to be alerted.
e161c Power Supply # (# # # W) lost AC power. Check PSU cables. (Power supply # (# # # W) AC power is interrupted. Please check the PSU cable. ) has a specific power device attached to the system, but no AC input.
E1620 Power Supply # (# # # W) AC power error. Check PSU cables. (Power Device # (# # # W) AC power error. Please check the PSU cable. The AC input for a particular power device is outside the permitted range.
E1624 Lost power supply redundancy. Check PSU cables. (Loss of power device redundancy.) Please check the PSU cable. The power device subsystem no longer provides redundancy. If the remaining power supplies are wrong, the system shuts down.
E1626 Power supply mismatch. PSU1 = # # # W, PSU2 = # # # W. (Power device mismatch.) PSU1 = # # # W, PSU2 = # # # W. Power supply devices in the system are different in power.
E1629 Power required > PSU wattage. Check PSU and CONFIG. (power required is greater than PSU power.) Please check the PSU and configuration. System configuration requires more power than the power supply can provide, even in the presence of throttling.
E1710 I/O channel check error. Review & Clear SEL. (I/O channel check error. Please check and clear the SEL. The system BIOS has reported I/O channel checks.
E1711 PCI Parity error on bus # # device # # function # # (BUS # # devices # # # features # # PCI parity errors) The system BIOS has reported that the component has a PCI parity error, which is located on bus # # Device # # function # # of PCI configuration space.
PCI parity error on Slot #. Review & Clear SEL. (Slot # on PCI parity error. Please check and clear the SEL. The system BIOS has reported a PCI parity error for the component that is located in the specified slot.
E1712 PCI system error on bus # # device # # # (Bus # # devices # # # features # # PCI system Errors) The system BIOS has reported that the component has a PCI error, the component is located on the bus # # Device # # # Features PCI configuration space.
PCI system error on Slot #. Review & Clear SEL. (Slot # PCI system error. Please check and clear the SEL. The system BIOS has reported that the component has a PCI system error that is located in the specified slot.
E1714 Unknown error. Review & Clear SEL. (Unknown error.) Please check and clear the SEL. The system BIOS has determined that there is an error in the system, but cannot determine the source of the error.
E1715 Fatal I/O error (Critical I/O errors) Review & Clear sel. (Please check and clear the SEL.) ) The system BIOS determines that there is a critical error in the system.
E1716 Chipset IERR Bus # # Dev # # Function # #. Review & Clear SEL. (Chip-Set IERR bus # # device # # function # #. Please check and clear the SEL. The system BIOS reports a chip set internal error that resides in bus # #, device # #, function # #.
E1717 CPU # Internal error. Review & Clear SEL. (CPU # Internal error. Please check and clear the SEL. The system BIOS determines that an internal error has occurred on the specified processor.

e171f PCIe fatal error on bus # # device # function # # (BUS # # devices # # # features # PCIe fatal error) The system BIOS has reported that the component has a PCIe fatal error, the component is located in bus # # # # # function # # of PCI configuration space.
PCIe fatal error on Slot #. Review & Clear SEL. (Slot # PCIe fatal error. Please check and clear the SEL. The system BIOS has reported that the component has a PCIe fatal error that is located in the specified slot.
E1810 hard Drive # # fault. Review & Clear SEL. (Hard drive # # failure. Please check and clear the SEL. The specified hard drive fails.
E1812 hard Drive # # removed. Check Drive. (Hard drive # # has been removed. Please check the drive. The specified hard drive has been removed from the system.
E1A11 PCI Riser Hardware & configuration mismatch. Reconfigure. (PCI riser hardware does not match the configuration.) Please reconfigure. The PCIe riser is not configured correctly. Some invalid configurations will prevent the system from powering up.

E1a12 PCI Riser not detected. Check Riser. (The PCI riser is not detected.) Please check the riser board. ) Loss of one or two PCIe riser boards. This will prevent the system from booting.
E1A14 SAS Cable A failure. Check connection. (SAS cable A failure. Please check the connection. ) SAS cable A is missing or damaged.
E1A15 SAS Cable B failure. Check connection. (SAS cable B failure. Please check the connection. ) SAS cable B is missing or damaged.
E1A1D Control panel USB cable not detected. Check cable. (The Control Panel USB cable is not detected.) Please check the cable. ) The USB cable connected to the Control Panel is missing or damaged.
E2010 Memory not detected. Inspect DIMMs. (Memory not detected.) Please check the DIMMs. Memory is not detected in the system.
E2011 Memory configuration failure. Check DIMMs. (Memory configuration failure.) Please check the DIMMs. Memory is detected, but the memory is not configurable. An error was detected during configuration memory.
E2012 Memory configured but unusable. Check DIMMs. (Memory is configured, but not available.) Please check the DIMMs. Memory is configured, but not available.
E2013 BIOS Unable to shadow memory. Check DIMMs. (BIOS cannot access shadow memory.) Please check the DIMMs. The system BIOS cannot copy its fast-erase image into memory.
E2014 CMOS RAM failure. Power cycle AC. (CMOS RAM failure.) Please turn off AC power and turn it on. ) CMOS is faulted. CMOS RAM is not working properly.
E2015 DMA Controller failure. Power cycle AC. (DMA controller failure.) Please turn off AC power and turn it on. ) The DMA controller fails.
E2016 Interrupt Controller failure. Power cycle AC. (Interrupt controller failure.) Please turn off AC power and turn it on. The interrupt controller fails.
E2017 Timer Refresh failure. Power cycle AC. (Timer refresh failure.) Please turn off AC power and turn it on. ) Timer refresh failure.

E2018 Programmable Timer error. Power cycle AC. (Programmable timer error.) Please turn off AC power and turn it on. ) Programmable Interval Timer error.
E2019 Parity error. Power cycle AC. (Parity error. Please turn off AC power and turn it on. ) Parity error.
E201A Superio failure. Power cycle AC. (Superio fault. Please turn off AC power and turn it on. ) The SIO fails.
e201b Keyboard Controller error. Power cycle AC. (Keyboard controller error.) Please turn off AC power and turn it on. ) Keyboard controller failure. (keyboard controller failure.) )
E201C SMI initialization failure. Power cycle AC. (SMI initialization failed.) Please turn off AC power and turn it on. System Management Interrupt (SMI) initialization failed.
E201D Shutdown test failure. Power cycle AC. (Shutdown Detection program failed.) Please turn off AC power and turn it on. ) The BIOS shutdown detection program failed.
E201E POST Memory test failure. Check DIMMs. (POST memory detection failed.) Please check the DIMMs. ) BIOS POST memory detection failed.
E2020 CPU configuration failure. Check screen message. (CPU configuration failed.) Please check the screen information. ) processor configuration failed.
E2021 incorrect memory configur-ation. Review User Guide. (The memory configuration is incorrect.) Please refer to the User Guide. The memory is not configured correctly.
E2022 general failure during POST. Check screen message. (General failure during POST.) Please check the screen information. ) A general failure occurred after the video.
E2023 BIOS Unable to mirror memory. Check DIMMs. (BIOS cannot mirror memory.) Please check the DIMMs. The system BIOS cannot enable the memory mirroring feature because the memory module fails or the memory configuration is invalid.
E2110 multibit Error on DIMM # #. Reseat DIMMs. (Multiple-bit error on DIMM # # #. Please reset the DIMM. A multiple-bit error (MBE) has occurred in the memory module in slot "# #".
E2111 SBE Log disabled on DIMM # #. Reseat DIMM. (The SBE log on the DIMM # # has been disabled. Please reset the DIMM. The system BIOS has disabled the memory unit error (SBE) record, and no more SBE will be logged until the system is rebooted. "# #" represents the memory module indicated by the BIOS.
E2113 Mem Mirror OFF on DIMM # # & # #. Power cycle AC. (DIMM # # # and # # # on the memory mirroring off. Please turn off AC power and turn it on. Because the system BIOS determines that there are too many errors in half of the mirrors, the Memory mirroring feature is disabled. "# # and # #" represents the memory module pair indicated by the BIOS.
I1910 intrusion detected. Check chassis cover. (Intrusion detected. Please check the chassis cover. ) The system cover has been removed.
I1912 SEL full. Review & Clear Log. (SEL is full.) Please check and clear the log. The SEL logged events are full and other content cannot be logged.
W1228 RAID Controller Battery capacity < 24hr. (RAID controllers have a battery capacity of less than 24 hours.) Pre-warning the RAID battery only has less than 24 hours of power.
W1627 Power required > PSU wattage. Check PSU and CONFIG. (power required is greater than PSU power.) Please check the PSU and configuration. The system configuration requires more power than the power supply can provide.
W1628 performance degraded. Check PSU and System configur-ation. (Performance degradation. Please check the PSU and system configuration. The system configuration requires more power than the power supply can provide, but can be booted if throttling is used.


DELL R710 Error code Rollup

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.