DellPowerEdgeR410bmc remote restart shutdown startup server

Source: Internet
Author: User
DellPowerEdgeR410bmc remote restart shutdown boot server ipmish installation put into dell built-in CD mounted on CD mount/dev/cdrom/mntwindows BMC/mnt/SYSMGMT/ManagementStation/windows/BMClinux BMC/mnt/SYSMGMT /Manage... dell PowerEdge R410 bmc remote restart shutdown boot server ipmish installation put into dell built-in CD mounted on CD mount/dev/cdrom/mntwindows BMC/mnt/SYSMGMT/ManagementStation/windows/BMClinux BMC/ mnt/SYSMGMT/ManagementStation/linux/bmcwindows copy the files under BMC to the windows machine and then run BMC. EXE www.2cto.com. Directory after NEXT installation: 64-bit system: C: \ Program Files (x86) \ Dell \ SysMgt \ bmc32-bit system: C: \ Program Files \ Dell \ SysMgt \ bmc can be added to PATH for convenience next time, next time you use ipmish directly can use the linux installation rpm-ivh osabmcutil9g-RHEL-4.4-0.i386.rpmrpm-ivh ipmitool/select the linux system version/ipmitool-1.8.11-99.dell.4.124.1.el6.x86_64.rpmipmish help and use www.2cto.com localhost ~ # IpmishPowered by AvocentBMC Management Utility-IPMISH v4.4 Release 0 Copyright 2009-Avocent Corporation (http://www.avocent.com/dell/bmu/ng) Usage: identify [on [-t ] | Off] LCD [info | set {none | default | custom }] Power [status | off [-force] | on | reset | cycle] powermonitor [status | clear {peakpower | cumulativepower}] [status | clear {peakpower | cumulativepower}] sel [[get [[-begin ] [-Max |-End ] |-Last ] [-Format ] | Clear | status] sensor [temp | fan | volt | discrete | numeric] [-format ] Sol [enable | disable | config [-baud <9600 | 19200 | 57600 | 115200>] [-priv] [-retrycount ] [-Retryinterval ] Sysinfo [fru | id] lcdNAME LCD-control the front panel LCD. SYNOPSIS LCD [info | set {none | default | custom }] DESCRIPTION this command is used to control the LCD labels on the front panel. SUB-COMMANDS info-display the settings of the current front panel LCD label. this is the default SUB-command. Set-set the LCD label on the front panel. PowerNAME power-controls the power status of the remote management server. SYNOPSIS power status | on | cycle | reset power off [-force] DESCRIPTION this command is used to display the current power status management server, enable/disable or restart the server. SUB-COMMANDS status-the server that displays the current power status. The return value is "on" or "off ". On-power off on the server-issue the "normal shutdown" IPMI command. Cycle-shut down the server and then enable it for a period of time. Reset-power status of the reset signal of the Pulse system. OPTIONS-force this option will simulate pressing the power button and force the system off. PowermonitorNAME powermonitor-system power monitoring SYNOPSIS powermonitor [status | clear {peakpower | cumulativepower}] DESCRIPTION this command is used to monitor the power usage of the system. SUB-COMMANDS status-displays the power usage of the system. This is the default sub-command. Clear-allows you to clear data stored by power monitoring. SelNAME sel-system event log for the operation. SYNOPSIS sel get [[-begin ] [-Max |-End ] |-Last ] [-Format ] Sel clear sel status DESCRIPTION this command allows you to delete all records in system event logs that execute certain operations, such as the total number of records in the log, and display the content in the event log. All or part of the SUB-COMMANDS get-printed event log. Clear-delete all records in the event log. Status-total number of system event log records displayed. OPTIONS-begin index1 indicates that the start record is displayed. -End index2 indicates the end of the record. -Max count: specifies the maximum number of records displayed. If The total number of records to be greater than. this option is invalid. The last record displayed will be the last one in the event log. -Last count: specifies the number of records to be printed. The number is counted from the last record. -Format Output SEL records in different formats. The default format is oemlist. Traditional display SEL records are consistent with BMU records of earlier versions. . SensorNAME sensor-displays the current status of the platform sensor. SYNOPSIS sensor [temp | fan | volt | discrete | numeric] [-format ] DESCRIPTION this command displays the current status of the platform sensor using one of two possible formats. OPTIONS [temp | fan | volt | discrete | numeric] specifies the sensor Group (temperature, voltage, fan, discrete, or number), where the information is displayed. If you do not specify a sensor group, all the sensors will be displayed with information. -Format Output sensor data in different formats. The default format is oemlist. The traditional format is shown as follows: Sensor Name | Sensor Type | Sensor # | Status [| Value | Units] solNAME sol-allows users to enable and disable servers connected to SOL, or configure the lowest permission parameters required by the baud rate and SOL, and configure the bmc sol retry times and interval parameters. SYNOPSIS sol enable | disable | config [-baud <9600 | 19200 | 57600 | 115200>] [-priv] [-retrycount ] [-Retryinterval ] DESCRIPTION: this command allows you to enable or disable servers connected to SOL, or configure the lowest permission parameters required for baud rate and SOL, and configure the bmc sol retry times and interval parameters. SUB-COMMANDS enable-allows users to enable servers connected to SOL. Disable-allows users to disable servers connected to SOL. Config-allows you to set the baud rate and minimum privilege parameter SOL, or configure bmc sol retries and interval parameters. OPTIONS-baud <波特率> Set the baud rate SOL. -Priv Set the minimum required privilege SOL. -Retrycount Set the bmc sol retry count parameter. -Retryinterval Set the bmc sol retry Interval parameter. Www.2cto.com sysinfoNAME sysinfo-retrieve and display system information. SYNOPSIS sysinfo [fru | id] DESCRIPTION this command is used to retrieve and display system information, including FRU and BMC information. SUB-COMMANDS fru-returns FRU-related information. Id-relevant information about BMC is returned. Example: ipmish-ip 192.168.2.12-u root-p 123456 sysinfo fru # View FRU-related information, ipmish-ip 192.168.2.12-u root-p 123456 power status including model # check whether the current host status is OFF. On, ipmish-ip 192.168.2.12-u root-p 123456 power off # normal shutdown, add-force to force shutdown ipmish-ip 192.168.2.12-u root-p 123456 power on # start the machine ipmish-ip 192.168.2.12-u root-p 123456 sel get # obtain the system log ipmish-ip 192.168.2.12-u root-p 123456 sensor temp # View device temperature and fan speed ipmish-ip 192.168.2.12-u root-p 123456 sysinfo fru # View server system problems

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.