JSQ-4000 is a all-digital time-controlled switchboard, the use of full decentralized control, the user and the number of relay ports can be optional according to user needs, can be used as user switches, private network switches and C5 end of the board switch.
1 Extension User failure
User interface Board is directly connected with the extension user interface in the switch, each user has a separate user circuit, user circuit using Slic (thick film circuit) +comdec (compiled code circuit).
If no dial tone is picked, the extension port is first found on the distribution frame (after disconnecting the outside line). For the outside line: the user outside the short circuit or open, the user's phone is broken, may result in picking machine without dial tone; for device side: This extension port parameter setting error (extension set only allow to answer) will also have no dial tone.
If the phone is ringing and the phone is normal, first find the extension port on the wiring rack (after disconnecting the outside line) to determine the test. For the outside side: the user outside the open line, mixing lines or the most of the atmosphere can cause the phone is not a bell or a ringing ring, the user phone ringing circuit is bad, should be replaced. Device side: The user board on the port of the ring relay or ringing related circuit is broken, the user board should be replaced. If the entire module users are not bell, it may be the PSU board of the 0.75A fuse broken, you must replace the same specifications of the fuse or generate a Bell Flow module power supply, or replace the PSU board.
The same module has several extension ports to pick up the dialing dial tone (Dual Audio extension), but the pulse extension can cut off the dial tone, may be on the MCPU board U29 (29ee010) chip broken.
In addition, observe the light on the circuit board or listen to the sound can also judge the fault, such as the call to the user, the relay has a "squeak" fibrillation, most of the user outside the capacitor is too large, line insulation is not good, phone and machine too many, bad phone and so on.
2 Relay Failure
The relay interface is the port to which the user switch is connected with the superior, and the connection between the user and the outside line must be through the relay interface.
Often hear the user reflected dial "0" after not to go out (silent) or call the operator no answer and no voice prompts (switchboard people on duty), first of all in the wiring frame to determine the local call out, into the relay access switch is normal, such as the individual out of the relay port without dial tone, please to the Telecommunications Bureau 112 fault station reflected. On the wiring racks will all into the relay short-circuit, and then dial into the relay or a single into the relay number, if you can still hear the ring tone, please contact the Telecommunications Bureau to resolve. In the normal situation of the local bureau, the above failures may be: (1) The relay board individual port is not good, replace 3845 chip or whole block relay board. (2) The switch side data is incorrect, such as the loss of relay data or the incorrect access and relay settings. (3) Incorrect relay data was loaded. It is worth mentioning that the use of loop relay of the user switch outgoing calls about 1min of disconnection (relay release) phenomenon, generally for the relay without the signal, but the relay parameter set to "recognition". Due to the native software for the identification of the reverse polarity signal relay, if the relay 1min does not receive the reverse polarity signal is considered to be a problem, can not connect the phone and will relay release, so if the trunk has no reverse polarity signal, do not set the counter polarity signal to "identify."
3 billing system does not receive the message list
A billing system that does not accept a single message may be one of the following reasons.
(1) Some related parameters (communication rate, communication serial port, and traffic record selection) in the billing system. General communication serial port selection serial one, the choice of traffic records to the long city agriculture as a traffic record; for the NCPU board of the communication rate should choose 9600baud, no NCPU board communication rate should choose 2400baud.
(2) The time limit of the billing system is set too long (such as 999s).
(3) The switch and the computer not connected to the machine, and did not send out the order, generally NCPU board on the 96fs174 or 96fs175 have problems.
(4) The computer on the 422 card has problems with the switch not connected to the machine, this problem is generally caused by lightning strikes or because the computer terminal does not share with the switch, there is a switch connected to the computer terminal cable has a high voltage or large current through, resulting in 422 of cards on the 96fs174,96fs175 bad.
(5) With the use of the Chinese character system has a conflict of functions, such as the Pinyin ucdos Chinese characters, Wubi input, and then press ALT+F6 switch back to the English state, the billing system clock does not go. At this point, click the space bar or ESC key, the billing system clock will go, but also normal to receive the switch to send a single, this is a false panic.
(6) All Chinese character systems or operating systems have problems, such as software virus infection or the use of pirated software.
(7) All billing system software and switch software does not match.
(8) Computer terminals connected with the switch cable line disconnection, from 422 card to the serial port flat cable disconnected, is generally bitten by the mouse or broken.
(9) The billing function of the corresponding outgoing number in the maintenance Taichung is set to close, and it can be turned on.