And Mindjet has an inseparable relationship, many functions rely on the Mindmanager Mindjet connection to achieve, if Mindjet connect out of the wrong what to do. This paper introduces a kind of Mindmanager Mindjet connection Error situation and the solution.
Problem Description: a Visual C + + runtime error message appearswhen connecting to the Mindjet connect account , MindManager aborts and exits.
Problem Analysis: Mindjet Connect file buffering is corrupted.
Resolution:
The buffered files need to be manually deleted. Deleting these files will have no effect on the software application.
Windows Vista:
1. enter start start – select Computer computer . in "Organize finishing " menu, choose Folder Options " then go to search options. In " view " "show hidden files and Folders show hidden files and folders "
2. Browse the following directories:
C:\Users\userprofile\AppData\Local\Mindjet\MindManager\15\DenaliCache\13
"UserProfile" is the login name for the account.
3. in this directory, there should be a folder named "13."
4. delete the folder.
5. Restart MindManager and link to mindjet Connect.
Windows XP:
1. open My Computer . in " tools " menu, go to " Folder Options " " view " "show hidden files and Folders show hidden files and folders "
2. Browse the following directories: C:\Documents and Settings\userprofile\appdata\local settings\applicationdata\ Mindjet\mindmanager\15\denalicache\
3. in this directory, there should be a folder named "13."
4. delete the folder.
5. Restart MindManager and link to mindjet Connect.
(Original: mind map software Reprint annotated source infringement must investigate )