WinXP,Win7,Win8
複製代碼 代碼如下:'原創內容轉載、引用代碼核心部分請註明出處
硬碟讀寫統計.vbs
If (Lcase(Right(Wscript.FullName,11)) = "wscript.exe") Then
CreateObject("WScript.Shell").Run("%Comspec% /C " &Chr(34)&"mode con cols=52 lines=22" &"&Title 硬碟讀寫統計.vbs By: FastSLZ PCEVA Or BatHome &&Cscript.exe //NoLogo "&Chr(34)& Wscript.ScriptFullName &Chr(34)&Chr(34)),3:Set WMI = Nothing:Wscript.Quit
End If
Dim WMI,vName,IDE,cPPP,sNow
Input = 1:InputS = Input*980
On Error Resume Next
Set WMI = GetObject("winmgmts:{impersonationLevel=impersonate}!\\.\root\cimv2")
Set IDE = WMI.ExecQuery("Select * from Win32_DiskDrive WHERE InterfaceType='IDE'")
Set cPPP = WMI.ExecQuery("SELECT * FROM Win32_PerfRawData_PerfDisk_PhysicalDisk WHERE Name <> '_Total'")
For Each oIDE In IDE
For i = 0 To IDE.Count
Select Case oIDE.Index
Case i
For Each oPPP In cPPP
If InStr(oPPP.Name, i) Then vName = oPPP.Name
Next
Select Case i
Case 0 Disk0=oIDE.Caption&" "&oIDE.FirmwareRevision:Size0=oIDE.Size:DskP0=vName
Case 1 Disk1=oIDE.Caption&" "&oIDE.FirmwareRevision:Size1=oIDE.Size:DskP1=vName
Case 2 Disk2=oIDE.Caption&" "&oIDE.FirmwareRevision:Size2=oIDE.Size:DskP2=vName
Case 3 Disk3=oIDE.Caption&" "&oIDE.FirmwareRevision:Size3=oIDE.Size:DskP3=vName
Case 4 Disk4=oIDE.Caption&" "&oIDE.FirmwareRevision:Size4=oIDE.Size:DskP4=vName
Case 5 Disk5=oIDE.Caption&" "&oIDE.FirmwareRevision:Size5=oIDE.Size:DskP5=vName
End Select
End Select
Next
Next
Set cPPP = Nothing:Set IDE= Nothing
If Disk0 <> "" Then WScript.Echo Left(DskP0,1)&":"&vbTab& Disk0 &vbTab _
&vbCrLf&vbTab&"廠商容量:"&Round(Size0/1000000000) &"GB" _
&vbCrLf&vbTab&"實際容量:"&Round(Size0/1073741824,2) &"GB" _
&vbCrLf&vbTab&"分區狀態:"&Right(DskP0,Len(DskP0)-2)
If Disk1 <> "" Then WScript.Echo Left(DskP1,1)&":"&vbTab& Disk1 &vbTab _
&vbCrLf&vbTab&"廠商容量:"&Round(Size1/1000000000) &"GB" _
&vbCrLf&vbTab&"實際容量:"&Round(Size1/1073741824,2) &"GB" _
&vbCrLf&vbTab&"分區狀態:"&Right(DskP1,Len(DskP1)-2)
If Disk2 <> "" Then WScript.Echo Left(DskP2,1)&":"&vbTab& Disk2 &vbTab _
&vbCrLf&vbTab&"廠商容量:"&Round(Size2/1000000000) &"GB" _
&vbCrLf&vbTab&"實際容量:"&Round(Size2/1073741824,2) &"GB" _
&vbCrLf&vbTab&"分區狀態:"&Right(DskP2,Len(DskP2)-2)
If Disk3 <> "" Then WScript.Echo Left(DskP3,1)&":"&vbTab& Disk3 &vbTab _
&vbCrLf&vbTab&"廠商容量:"&Round(Size3/1000000000) &"GB" _
&vbCrLf&vbTab&"實際容量:"&Round(Size3/1073741824,2) &"GB" _
&vbCrLf&vbTab&"分區狀態:"&Right(DskP3,Len(DskP3)-2)
If Disk4 <> "" Then WScript.Echo Left(DskP4,1)&":"&vbTab& Disk4 &vbTab _
&vbCrLf&vbTab&"廠商容量:"&Round(Size4/1000000000) &"GB" _
&vbCrLf&vbTab&"實際容量:"&Round(Size4/1073741824,2) &"GB" _
&vbCrLf&vbTab&"分區狀態:"&Right(DskP4,Len(DskP4)-2)
If Disk5 <> "" Then WScript.Echo Left(DskP5,1)&":"&vbTab& Disk5 &vbTab _
&vbCrLf&vbTab&"廠商容量:"&Round(Size5/1000000000) &"GB" _
&vbCrLf&vbTab&"實際容量:"&Round(Size5/1073741824,2) &"GB" _
&vbCrLf&vbTab&"分區狀態:"&Right(DskP5,Len(DskP5)-2)
WScript.Echo "↑請輸入要監控的硬碟編號,並按斷行符號鍵"
stdInput = WScript.StdIn.Readline
stdInput=Left(UCase(stdInput),1)
If stdInput > "5" Or stdInput < "0" Then MsgBox "輸入錯誤" :WScript.Quit
If InStr(DskP0, stdInput) Then Call Network(Disk0,Size0,DskP0)
If InStr(DskP1, stdInput) Then Call Network(Disk1,Size1,DskP1)
If InStr(DskP2, stdInput) Then Call Network(Disk2,Size2,DskP2)
If InStr(DskP3, stdInput) Then Call Network(Disk3,Size3,DskP3)
If InStr(DskP4, stdInput) Then Call Network(Disk4,Size4,DskP4)
If InStr(DskP5, stdInput) Then Call Network(Disk5,Size5,DskP5)
Sub Network(Disks,Sizes,DskPs)
sNow=Now
Do
Dim A
'WScript.Echo "已運行"&Ts\3600&"小時"&(Ts mod 3600)\60&"分鐘"&(Ts mod 3600) mod 60&"秒"
Set A = WMI.ExecQuery("Select * from Win32_PerfRawData_PerfDisk_PhysicalDisk Where Name='"&DskPs&"'")
For Each B In A
R1 = B.DiskReadBytesPersec
W1 = B.DiskWriteBytesPersec
If RA0 = "" Then RA0 = B.DiskReadBytesPersec Else RA1 = R1 End If
If WA0 = "" Then WA0 = B.DiskWriteBytesPersec Else WA1 = W1 End If
Next
Set A = Nothing
WScript.Sleep(InputS)
Set A = WMI.ExecQuery("Select * from Win32_PerfRawData_PerfDisk_PhysicalDisk Where Name='"&DskPs&"'")
For Each B In A
R2 = B.DiskReadBytesPersec
W2 = B.DiskWriteBytesPersec
Next
Set A = Nothing
WScript.Echo Disks &" " &Round(Sizes/1073741824) &"GB" &vbCrLf _
&"即時讀取:" & CheckSize((R2-R1)/Input) &"/s" &vbCrLf _
&"即時寫人:" & CheckSize((W2-W1)/Input) &"/s"&vbCrLf _
&"指令碼累計讀取:" & CheckSize(RA1-RA0) &vbCrLf _
&"指令碼累計寫入:" & CheckSize(WA1-WA0) &vbCrLf _
&"開機累計讀取:" & CheckSize(R1) &vbCrLf _
&"開機累計寫入:" & CheckSize(W1) &vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf _
&"已運行"&Ts\3600&"小時"&(Ts mod 3600)\60&"分鐘"&(Ts mod 3600) mod 60&"秒"
Ts=DateDiff("s", sNow, Now)'Ts=TS+1
Loop
End Sub
Function CheckSize(SZ)
On Error Resume Next
If SZ => 1073741824 Then
SZ = FormatNumber(Round(SZ/1073741824,2))&" GB"
ElseIf SZ => 1048576 Then
SZ = FormatNumber(Round(SZ/1048576,2))&" MB"
ElseIf SZ => 1024 Then
SZ = FormatNumber(Round(SZ/1024,2))&" KB"
Else
SZ = "0"&FormatNumber(Round(SZ/1024,2)) & " KB"
End If
CheckSize=Right(" " & SZ,10)
End Function
分區讀寫統計.vbs複製代碼 代碼如下:'原創內容轉載、引用代碼核心部分請註明出處
If (Lcase(Right(Wscript.FullName,11)) = "wscript.exe") Then
CreateObject("WScript.Shell").Run("%Comspec% /C " &Chr(34)&"mode con cols=52 lines=22" &"&Title 分區讀寫統計.vbs By: FastSLZ PCEVA Or BatHome &&Cscript.exe //NoLogo "&Chr(34)& Wscript.ScriptFullName &Chr(34)&Chr(34)),3:Set WMI = Nothing:Wscript.Quit
End If
Input = 1:InputS = Input*1000
Dim WMI,vName,IDE,cPPP,sNow
On Error Resume Next
Set WMI = GetObject("winmgmts:{impersonationLevel=impersonate}!\\.\root\cimv2")
Set IDE = WMI.ExecQuery("Select * from Win32_DiskDrive WHERE InterfaceType='IDE'")
Set cPPP = WMI.ExecQuery("SELECT * FROM Win32_PerfRawData_PerfDisk_PhysicalDisk WHERE Name<>'_Total'")
For Each oIDE In IDE
For i = 0 To IDE.Count
Select Case oIDE.Index
Case i
For Each oPPP In cPPP
If InStr(oPPP.Name, i) Then vName = oPPP.Name
Next
Select Case i
Case 0 Disk0=oIDE.Caption&" "&oIDE.FirmwareRevision:Size0=oIDE.Size:DskP0=vName
Case 1 Disk1=oIDE.Caption&" "&oIDE.FirmwareRevision:Size1=oIDE.Size:DskP1=vName
Case 2 Disk2=oIDE.Caption&" "&oIDE.FirmwareRevision:Size2=oIDE.Size:DskP2=vName
Case 3 Disk3=oIDE.Caption&" "&oIDE.FirmwareRevision:Size3=oIDE.Size:DskP3=vName
Case 4 Disk4=oIDE.Caption&" "&oIDE.FirmwareRevision:Size4=oIDE.Size:DskP4=vName
Case 5 Disk5=oIDE.Caption&" "&oIDE.FirmwareRevision:Size5=oIDE.Size:DskP5=vName
End Select
End Select
Next
Next
Set cPPP = Nothing:Set IDE= Nothing
If Disk0 <> "" Then DskP=Right(DskP0,Len(DskP0)-2):WScript.Echo Left(DskP0,1)&":"&vbTab& Disk0 &vbTab _
&vbCrLf&vbTab&"分區狀態:"&Right(DskP0,Len(DskP0)-2)
If Disk1 <> "" Then DskP=DskP&" "&Right(DskP1,Len(DskP1)-2):WScript.Echo Left(DskP1,1)&":"&vbTab& Disk1 &vbTab _
&vbCrLf&vbTab&"分區狀態:"&Right(DskP1,Len(DskP1)-2)
If Disk2 <> "" Then DskP=DskP&" "&Right(DskP2,Len(DskP2)-2):WScript.Echo Left(DskP2,1)&":"&vbTab& Disk2 &vbTab _
&vbCrLf&vbTab&"分區狀態:"&Right(DskP2,Len(DskP2)-2)
If Disk3 <> "" Then DskP=DskP&" "&Right(DskP3,Len(DskP3)-2):WScript.Echo Left(DskP3,1)&":"&vbTab& Disk3 &vbTab _
&vbCrLf&vbTab&"分區狀態:"&Right(DskP3,Len(DskP3)-2)
If Disk4 <> "" Then DskP=DskP&" "&Right(DskP4,Len(DskP4)-2):WScript.Echo Left(DskP4,1)&":"&vbTab& Disk4 &vbTab _
&vbCrLf&vbTab&"分區狀態:"&Right(DskP4,Len(DskP4)-2)
If Disk5 <> "" Then DskP=DskP&" "&Right(DskP5,Len(DskP5)-2):WScript.Echo Left(DskP5,1)&":"&vbTab& Disk5 &vbTab _
&vbCrLf&vbTab&"分區狀態:"&Right(DskP5,Len(DskP5)-2)
WScript.Echo vbCrLf&"請輸入"&DskP&"中任意一個盤符"
stdInput = WScript.StdIn.Readline
stdInput=Left(UCase(stdInput),1)
If InStr(DskP,stdInput) Then Call Network(stdInput&":")
Sub Network(DskPs)
sNow=Now
Do
Dim A
Set A = WMI.ExecQuery("Select * from Win32_PerfRawData_PerfDisk_LogicalDisk Where Name = '"& DskPs &"'")
For Each B In A
R1 = B.DiskReadBytesPersec
W1 = B.DiskWriteBytesPersec
If RA0 = "" Then RA0 = B.DiskReadBytesPersec Else RA1 = R1 End If
If WA0 = "" Then WA0 = B.DiskWriteBytesPersec Else WA1 = W1 End If
Next
Set A = Nothing
WScript.Sleep(InputS)
Set A = WMI.ExecQuery("Select * from Win32_PerfRawData_PerfDisk_LogicalDisk Where Name = '"& DskPs &"'")
For Each B In A
R2 = B.DiskReadBytesPersec
W2 = B.DiskWriteBytesPersec
Next
Set A = Nothing
WScript.Echo "監控分區:" &DskPs &vbCrLf _
&"即時讀取:" & CheckSize((R2-R1)/Input) &"/s" &vbCrLf _
&"即時寫人:" & CheckSize((W2-W1)/Input) &"/s"&vbCrLf _
&"指令碼累計讀取:" & CheckSize(RA1-RA0) &vbCrLf _
&"指令碼累計寫入:" & CheckSize(WA1-WA0) &vbCrLf _
&"開機累計讀取:" & CheckSize(R1) &vbCrLf _
&"開機累計寫入:" & CheckSize(W1) &vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf _
&"已運行"&Ts\3600&"小時"&(Ts mod 3600)\60&"分鐘"&(Ts mod 3600) mod 60&"秒"
Ts=DateDiff("s", sNow, Now)'Ts=TS+1
Loop
End Sub
Function CheckSize(SZ)
On Error Resume Next
If SZ => 1073741824 Then
SZ = FormatNumber(Round(SZ/1073741824,2))&" GB"
ElseIf SZ => 1048576 Then
SZ = FormatNumber(Round(SZ/1048576,2))&" MB"
ElseIf SZ => 1024 Then
SZ = FormatNumber(Round(SZ/1024,2))&" KB"
Else
SZ = "0"&FormatNumber(Round(SZ/1024,2)) & " KB"
End If
CheckSize=Right(" " & SZ,10)
End Function