The industry has always been famous for providing excellent full-shield solutions. Its 7-class and 7A-class cables have reached a new level in terms of both process and performance, therefore, many customers who are pursuing high performance, especially many European customers, have chosen the right products because they are used to the high quality services of the company.
In China, a large number of terminal devices are still using RJ45 interfaces. As we all know, such eight copper-pin modules cannot meet the transmission standards of seven categories, CATEGORY 6A MHz is already its transmission limit, for example, 1, category 6A modules). To meet the Class 7 transmission standard, a 4-wire pair of fully isolated PS modules such as 2 must be adopted, the difference between the two modules is as clear as 3. Comparison between the two modules). to upgrade all the systems, you need to invest a lot of money. As a result, many customers, such as the German Volkswagen, have chosen a compromise solution. The cables in the wall are 7 types of devel cables, with a physical bandwidth of up to 1000 MHz. The module uses 6 categories of RJ45 modules, in the future, you can upgrade the entire link to seven categories by replacing the seven categories of modules, greatly saving the cost.
6A Module
Class 7 modules
Comparison between Class 7 modules and category 6A modules
Now let's take a look at how to strip the 6A class module. First, let's take a look at the two objects in this operation, such,
. 6A module Breakdown Diagram,
LSOH jacket for A and B .7 cables ).
6A module Breakdown Diagram
Printing of Class A Cables
Class B 7 cable structure
The first step is strip, such as 6. Strip the outermost sheath layer. We can see that the Class 7 lines of detewelle provide excellent shielding effects for aluminum foil shielding + total screen shielding. Then flip the Screen Layer back.
Wire stripping
Step 2: remove the aluminum foil shielding layer of the four-wire pair. Because it is an aluminum foil + double screen shielding structure, we can remove the aluminum foil layer, leaving the Screen Layer without affecting the overall shielding performance. For example, 7.
Remove aluminum foil Layer
Step 3: refer to the color mark position of the plastic cable trough module and trim the corresponding line pairs to facilitate the 4-wire pairs into the cable trough. 8A and 8B color labels. 9. trim the linefeed to a specific length.
Figure 8A color sequence
Figure 8B color label Sequence
Figure 9 trim Length
Step 4: extend the line pair to the corresponding block of the Line Slot module, 10. And unlock the line pair, according to the color mark the line into the trough, 11.
0 is in the block
1 card into the corresponding cable slot
Step 5: trim the excess cables, as shown in 12, and press the cable trough block into Module 13.
2. Trim excess Cables
3. Plug in the module
Step 1: press the metal pin into the module, 14, to fix the plastic card trough inserted in the previous step, the effect is 15.
4. Cards waiting for pushing
5. Press in
Step 7: Flip the top lid of the module and cover it with 16. Fixed with a tie, with a effect of 17. The whole module production process is completed, during which the screen shielding layer must be organized smoothly.
6. Flip down the module cover
7. Fixed with binding tape
Through the above introduction, we can feel that it is not complicated to strip the type 6A module, and it is completely a tool-free module, which greatly saves the construction time of the shielding system.
- Discussion on Integrated Wiring 6A system-advantages of Shielded Cables
- Integrated Wiring 6A system product highlights