6506> (enable) show config
This command shows non-default invocations only.
Use 'show config all' to show both default and non-default config
.........
................
................
..............
..
Begin
!
# ***** NON-DEFAULT CONFIGURATION *****
!
!
# Time: Thu Jan 4 2001, 08:27:22
!
# Version 5.4 (3) # Software version
!
Set password $2 $ lnsk $ mgJ84scE. A51hpr0Zbdfv/# encrypted telnet password
Set enablepass $2 $ RFAC $ BDgIVKdk3gl1RD4. DaNcu. # encrypted enable password
!
# System
Set system name 6506 # system name
!
#!
# Vtp
Set vtp domain _ domain # VTP domain Name
Set vtp passwd _ password # VTP domain password
Set vlan 1 name default type ethernet mtu 1500 said 100001 state # create a VLAN
Set vlan 2 name vlan2 type ethernet mtu 1500 said 100002 state act
Set vlan 3 name maid type ethernet mtu 1500 said 100003 state acti
Set vlan 1002 name fddi-default type fddi mtu 1500 said 101002 st
Set vlan 1004 name fddinet-default type fddinet mtu 1500 said 101
E stp ieee
Set vlan 1005 name trnet-default type trbrf mtu 1500 said 101005
P IBM
Set vlan 1003 name token-ring-default type trcrf mtu 1500 said 10
Ve mode sulfate aremaxhop 7 stemaxhop 7 backupcrf off
!
# Ip
Set interface sc0 1 10.1.1.253/255.255.255.0 10.1.1.255 # IP address of the vswitch
Set ip route 0.0.0.0/0.0.0.0 10.1.1.254 # Default Gateway
Set ip alias default 0.0.0.0 # set the device name corresponding to the ip address to facilitate management
Set ip alias 6506 10.1.1.253 # purpose: ping 2620, telnet 3548_2a
Set ip alias msfc 10.1.1.254
Set ip alias 4912 10.1.1.252
Set ip address alias 2620 10.1.8.250
...
!
# Set boot command
Set boot config-register 0x102 # startup register value and Startup File
Set boot system flash bootflash: cat6000-sup.5-4-3.bin
!
# Mls
Set mls flow full # multi-layer switching stream type
!
# Security ACLs # access list
Clear security acl all
# Server
Set security acl ip server deny ip host 10.1.1.199 host 10.1.1.200
#
Commit security acl all
!
# Default port status is enable
!
!
# Module 1: 2-port 1000 BaseX Supervisor # The management engine contains 2-port Gigabit modules)
!
# Module 2: 8-port 1000 BaseX Ethernet #8-port Gigabit Switching module
Set vlan 5 2/1 # specify port 2/1 to vlan 5
Set port name 2/1 gg # set port name
Set port name 2/2 cb
Set port name 2/3 server1
Set port name 2/4 server2
Setport name 2/5 3548_2a
Set udld enable 2/6-8 # activate detection when GBIC is not installed
Set trunk 2/1 off dot1q 1-1005 # set 2/1 as the trunk line running the 802.1Q protocol, allowing vlan 1-1005 to pass through
Set trunk 2/2 on dot1q 1-1005
Set trunk 2/3 on dot1q 1-1005
Set trunk 2/4 on dot1q 1-1005
Set trunk 2/5 nonegotiate isl 1-1005
!
# Module 3: 8-port 1000 BaseX Ethernet #8-port Gigabit Switching module
Set port name 3/4 3524_17a
Setport name 3/5 3548_9b
Setport name 3/6 3548_9a
Set port name 3/7 3548_f4a
Setport name 3/8 3548_12a
Set udld enable 3/1-3
Set trunk 3/1 on dot1q 1-1005
Set trunk 3/4 nonegotiate isl 1-1005 # set 3/4 as the trunk line for running the isl protocol, allowing vlan 1-1005 to pass through
Set trunk 3/5 nonegotiate isl 1-1005
Set trunk 3/6 nonegotiate isl 1-1005
Set trunk 3/7 nonegotiate isl 1-1005
Set trunk 3/8 nonegotiate isl 1-1005
!
# Module 4 empty
!
# Module 5 empty
!
# Module 6 empty
!
# Module 15: 1-port Multilayer Switch Feature Card
Set port name 15/1 msfc # routing and multilayer Switching Module
!
# Module 16 empty
End