Laser printer is the laser scanning technology, electronic technology, electrostatic imaging technology, such as integration of the printing and output equipment. It has the characteristics of fast printing, good printing quality, high resolution and low noise, and it is an important computer peripheral equipment. With the advent of network printers, it has become more and more widely used in office automation, printing, publishing, scientific research and other industries. Examples of maintenance failures are as follows:

Failure One: A laser printer image is obviously black and white on one side. After the replacement of the toner cartridge, the parts are all clean after the failure or still exist.

Head paper carefully wipe multiple shuttle mirror several of the reverse smooth, and then a few optical lens wipe clean, remove the plastic box to restore, pay attention to the wiring card connectors installed. After the boot, printed out the handwriting is very full.

Fault Two: A Canon St Laser printer often appears heating lamp does not light the fault, after the boot only one power supply light, the machine can not work properly.

Repair method: Through the inspection found that the problem is not a fixer, is not a power supply, small relay problems, but the power box next to a small box tube heating a 102J small resistor and circuit board contact is not good, because it is both sides of the circuit board, to both sides of the welding, electric chrome welding after troubleshooting. This fault in the St laser printer is very common, but sometimes the heating lamp is not bright is the power control part of one-way thyristor failure. Fixing the lamp, thermistor, heat protector fault is also more common. If the measurement fuser lamp burned out, the thermistor performance is not good, the heat protector open circuit to replace.

Fault Three: A Canon Bxⅱ laser printer's heating lamp sometimes light, sometimes not bright.

Repair Method: When the heating lamp is not lit, to use a multimeter to check the wiring of the 2 tube is broken, there are 7 thin wires broken, because Bxⅱ and KT laser printer fixing part and host connection is active, a few wires often disassembly easy to dismantle. If the heating lamp is often not bright, but after a long period of cooling can be used normally, this is the thermistor out of the question. Replace the new thermistor, collect the time to paint silly rose 饩 觥 s 蛴 hat pei onto empty h let hygiene loving stable shabu ?20kω, hot state 1.45kω.

Fault Four: The output image color is shallow, can not see the handwriting

a Canon LBP type laser printer, the output image color is shallow, the basic reading is not clear handwriting. Try to adjust the contrast knob to the maximum file, the output proofs are still unclear, consider the mirror dirty, with alcohol cotton ball will mirror and focus lens wipe clean, the fault is still. Check the transfer electrode wire is normal, did not see abnormal, and the electrode wire clean, the fault has not been ruled out. Check the powder box charging electrode wire, good and normal, check high pressure and high pressure contact also no problem, indicating that the fault is not related to electrode wire. The

further checks that a spring piece of the sensitive sensor switch of the laser-driven circuit is broken, causingPrinting machine is not closed when the work caused by the above fault. After replacing the new spring slice, troubleshoot.

Failure Five: fuser heating is not normal

a Canon Laser printer, power-on power indicator light, ready/waiting for the light flash is extinguished, fixing heaters only shining once also no longer heating, and sometimes the power-on fuser heater does not work at all. The

suspects that the fuser heater is poorly contacted or damaged, depending on the symptom. Remove the Fuser heater part, use the multimeter resistor to detect both ends of normal, detect thermistor and temperature sensor and protection circuit, no problem found. Check the main control Board interface circuit is also not abnormal. The

further examines the heating drive circuit and finds that there is a problem with the SCR. After the replacement of the new SCR, the fuser heater work back to normal, troubleshooting.
 

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.