smartsnippetstm Studio Installation Error collation
Qin Ji Chen Jieming technology
1 Device not detected
If you have finished installing the development environment, open the development environment, download and install dependencies, after the above work is determined we choose DA14683, then select the inspection device.
this time there may be a hint that the device is not detected, here's how to fix it:
Access SEGGER official website:https://www.segger.com/downloads/jlink/#J-linksoftwareanddocumentationpack, Locate the J-link software and documentation pack.
Select the version that is appropriate for your system and install it. (No installation path required)
2 cannot open GDB interface
when we import the project and compile it, the display compile can pass, but when we want to download the code to the Development Board, but the prompt:cannot open GDB interface
This problem is also because there is no installation J-link software and Documentation pack , we follow the above steps to install. If the installation is still not possible, please try to plug the Board again.
3 Pro Blem occurred
We can go back to the "Welcome" interface when we download the code to this error on the Development Board.
Select da14683-00 andthen detect the device to show that the connection was successful
Then go back to the code interface, recompile the code, and then choose to download the code, there will be no error.
if the above methods do not work, then turn off the development environment restart. If restarting the development environment still does not work, then locate J-link Remote Server in the taskbar and run it manually.
4 J Ava . lang. NullPointerException
Sometimes when you import new projects and delete projects, this problem occurs occasionally, just to restart the development environment to solve this problem.
......
DA14683 Development: Installation error finishing of development environment