EMC clariion CX4-120 simple installation Configuration

Source: Internet
Author: User

 

1. install hardware:
Storage processor enclosure (storage processor, SPE)
Disk-array enclosure (DAE)
Standby Power Supply (backup power supply, SPS)

1. a single line of SPS is connected to the SPE.
2. An SPE line connects to Dae.
3. A network cable is attached to each spe.

Ii. Initialization
1. Install the TLS storage system initialization on a PC.
2. Run this tool and the system will automatically scan the uninitialized storage system.
3. Configure the IP address and logon information of the uninitialized storage system.

3. Configure the Array
1. log on to the Controller through the configured IP Address
2. Right-click the raid group in the next menu of storage pools to create a raid group.
Raid group 0 first 5 hard disks RAID 5
Raid group 1 followed by 9 hard disks RAID 5
Raid group 2's last hard disk for hot spare
3. Create a lun on the raid group
Lun0 10 Gb raid group 0
Lun1 20 GB raid group 0
Lun2 10 Gb raid Group 1
Lun3 30 GB raid Group 1
4. Expand the Lun
There are two methods to expand the Lun
Striping requires that the idle Lun must be as large as the Lun capacity to be expanded.
Concatenation Luns of different sizes can be merged
Combine lun0 and lun2 into a metalun 0
Combine lun1 and lun3 into a metalun 1

4. Configure an optical fiber switch
All Optical fiber cables are connected.

5. Install the agent on the server
1. Install the agent
[Root @ tonykorn97 ~] # Rpm-IVH naviagent. noarch. rpm
Preparing... ######################################## ### [100%]
1: naviagent ####################################### #### [100%]
[Root @ tonykorn97 ~] # Rpm-AQ | grep naviagent
Naviagent-6.28.10.3.11-1
[Root @ tonykorn97 ~] # Rpm-QL naviagent-6.28.10.3.11-1.
/Etc/manager/supportedflarerevisions
/Etc/manager/agent. config
/Etc/init. d/naviagent
/Opt/manager/bin/naviagent
[Root @ tonykorn97 ~] #
[Root @ tonykorn97 ~] #/Etc/init. d/naviagent start
Starting manager agent: [OK]
[Root @ tonykorn97 ~] # Chkconfig -- list naviagent
Naviagent 0: off 1: off 2: off 3: On 4: On 5: on 6: Off
[Root @ tonykorn97 ~] #

The host name is displayed, but the following prompt is displayed:
Unknown: fiber: Host agent not reachable

2. Configure the access permission for the agent:
[Root @ tonykorn97 ~] # Vi/etc/manager/agent. config
After: User Root # Only on this machine, add:

User system@172.25.0.24
User system@172.25.0.25

Restart the agent service is the same,

3. A new system user is added with an error.

4. Install navicli
[Root @ tonykorn97 ~] # Rpm-IVH navicli. noarch. rpm
Preparing... ######################################## ### [100%]
1: navicli ####################################### #### [100%]
[Root @ tonykorn97 ~] # Rpm-AQ | grep navicli
Navicli-6.28.10.3.11-1
[Root @ tonykorn97 ~] # Rpm-QL navicli-6.28.10.3.11-1.
/Opt/manager/bin/navicli
/Opt/Mgr/bin/naviseccli
[Root @ tonykorn97 ~] #

[Root @ tonykorn97 ~] # Cd/opt/manager/bin/
[Root @ tonykorn97 bin] #./navicli-H 172.25.0.24 getall
Server IP Address: 172.25.0.24
Agent Rev: 6.28.10 (3.19)

5. Modify the/etc/hosts file on the server to match the Host IP address and name. Restart the server.
It is normal after restart.

6. Delete the System user test. The test result is still normal. The description is irrelevant to the user.

6. Install powerpath
1. Operating System 5.2 Installation failed:
[Root @ tonykorn97 EMC] # rpm-IVH emcpower. LINUX-5.1.1-017.rhel5.x86_64.rpm
Preparing... ######################################## ### [100%]
Expecting RedHat rhel5 system.
Found RedHat rhel5.2 system.
Error: % pre (emcpower. LINUX-5.1.1-017.x86_64) scriptlet failed, exit status 1
Error: Install: % pre scriptlet failed (2), skipping emcpower. LINUX-5.1.1-017
[Root @ tonykorn97 EMC] #

2. reinstall the RHEL 5.1x64 operating system,
3. Install poserpath
[Root @ tonykorn97 ~] # Rpm-IVH emcpower. LINUX-5.1.1-017.rhel5.x86_64.rpm
Preparing... ######################################## ### [100%]
1: emcpower. linux ####################################### #### [100%]
All trademarks used herein are the property of their respective owners.
Note: license registration is not required to manage the clariion ax series array.
[Root @ tonykorn97 ~] #

4. Add a key
[Root @ tonykorn97 ~] # Emcpreg-add ****-****-****-****-****-****
1 key (s) successfully added.
[Root @ tonykorn97 ~] # Emcpreg-list
Key ****-****-****-****-****-****
Product: powerpath
Capabilities: All
[Root @ tonykorn97 ~] #

[Root @ tonykorn97 ~] # Powermt check_registration
Key ****-****-****-****-****-****
Product: powerpath
Capabilities: All
[Root @ tonykorn97 ~] #

5. Start the service:
[Root @ tonykorn97 ~] #/Etc/init. d/powerpath start
Starting powerpath: Done
[Root @ tonykorn97 ~] #

6. view the disk information:
[Root @ tonykorn97 ~] # Powermt display Dev = all
Pseudo name = emcpowera
Clariion id = CKM ***********[~ Physical]
Logical Device id = 60060160162023007cea4f3721f3dd11 [Lun 0]
State = alive; Policy = claropt; priority = 0; queued-Ios = 0
Owner: default = sp B, current = sp B array failover mode: 1
========================================================== ==============================================
---------------- Host ----------------stor--- I/O path--- stats ---
### HW path I/O paths interf. mode state Q-Ios errors
========================================================== ==============================================
3 qla2xxx sdb sp B1 active alive 0 0
3 qla2xxx sdc sp A1 active alive 0 0
4 qla2xxx sdd sp B0 active alive 0 0
4 qla2xxx sde sp A0 active alive 0 0
5 qla2xxx sdf sp B1 active alive 0 0
5 qla2xxx sdg sp A1 active alive 0 0
6 qla2xxx sdh sp B0 active alive 0 0
6 qla2xxx sdi sp A0 active alive 0 0

[Root @ tonykorn97 ~] #

7. view the channel information:
[Root @ tonykorn97 ~] # Powermt display paths
Symmetrix logical device COUNT = 0
========================================================== ==============================================
----- Host bus adapters --------- ------ storage system ------I/O paths-
### HW path ID interface total dead
========================================================== ==============================================

Clariion logical device COUNT = 1
========================================================== ==============================================
----- Host bus adapters --------- ------ storage system ------I/O paths-
### HW path ID interface total dead
========================================================== ==============================================
3 qla2xxx CKM *********** SP B1 1 0
3 qla2xxx CKM *********** SP A1 1 0
4 qla2xxx CKM *********** SP B0 1 0
4 qla2xxx CKM *********** SP A0 1 0
5 qla2xxx CKM *********** SP B1 1 0
5 qla2xxx CKM *********** SP A1 1 0
6 qla2xxx CKM *********** SP B0 1 0
6 qla2xxx CKM *********** SP A0 1 0

Hitachi logical device COUNT = 0
========================================================== ==============================================
----- Host bus adapters --------- ------ storage system ------I/O paths-
### HW path ID interface total dead
========================================================== ==============================================

Invista logical device COUNT = 0
========================================================== ==============================================
----- Host bus adapters --------- ------ storage system ------I/O paths-
### HW path ID interface total dead
========================================================== ==============================================

Hp xp logical device COUNT = 0
========================================================== ==============================================
----- Host bus adapters --------- ------ storage system ------I/O paths-
### HW path ID interface total dead
========================================================== ==============================================

ESS logical device COUNT = 0
========================================================== ==============================================
----- Host bus adapters --------- ------ storage system ------I/O paths-
### HW path ID interface total dead
========================================================== ==============================================

Hp hsx logical device COUNT = 0
========================================================== ==============================================
----- Host bus adapters --------- ------ storage system ------I/O paths-
### HW path ID interface total dead
========================================================== ==============================================

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.