1. Unplug the power cord of the switch.
2. Connect the Super Terminal and the control line to the switch. The Super Terminal settings are as follows:
9600 baud rate
No parity
8 data bits
1 stop bit
No flow control
3. Press and hold the "mode" button on the front panel of the switch. Plug in the power cord. When the light on Port 1 is not on, relax the "mode" button,
4. At this time, the Super Terminal should display:
The system has been interrupted prior to initializing the flash file system.
The following commands will initialize the flash file system, and finish loading
The operating system software:
Flash_init
Load_helper
Boot
5. Enter flash_init.
6. Enter load_helper
7. Input dir flash:
It is displayed as follows:
Directory of flash:
2-rwx 843947 Mar 01 1993 00:02:18 C2900XL-h-mz-112.8-SA
4 drwx 3776 Mar 01 1993 01:23:24 html
66-rwx 130 Jan 01 1970 00:01:19 env_vars
68-rwx 1296 Mar 01 1993 06:55:51 config. text
1728000 bytes total (456704 bytes free)
8. Enter rename flash: config. text flash: config. old
9. Enter boot and restart the system.
10. After the system is started, it will show: Continue with the configuration dialog? [Yes/no]: Enter N
11. Enter enable
12. After Entering enable mode, enter rename flash: config. old flash: config. text
13. follow these steps:
Switch # copy flash: config. text system: running-config
Source filename [config. text]? (Press Return)
Destination filename [running-config]? (Press Return)
14. follow these steps:
Switch # configure terminal
Switch (config) # no enable secret
Switch (config) # no enable password
Switch (config) # exit
Switch # write memory
At this time, the system will be restored without a password