iSCSI Storage Modules

Source: Internet
Author: User

1. Install the iSCSI target package and start the service :

# yum Install-y targetcli

# Systemctl enable target; Systemctl start target

2. Enter the ISCSI Target Interactive configuration mode :

# TARGETCLI

650) this.width=650; "style=" width:658px;height:195px; "title=" Picture 1.png "src=" http://s3.51cto.com/wyfs02/M02/6E/66/ Wkiom1v612axfj1waahiyw3wc4k963.jpg "width=" 754 "height=" 412 "alt=" wkiom1v612axfj1waahiyw3wc4k963.jpg "/>

4.TARGETCLI for configuration

/>/backstores/block Create SERVER0.DISK1/DEV/ISCSI_VG/DISK1_LV//give the hard drive an alias

Created Block Storage Object Server0.disk1 using/dev/iscsi_vg/disk1_lv.

/>/ISCSI Create Iqn.2014-12.com.example:server0

Created Target Iqn.2014-12.com.example:server0.

Created TPG 1.

/>/iscsi/iqn.2014-12.com.example:server0/tpg1/luns Create/backstores/block/server0.disk1

Created LUN 0.

Created LUN 0->0 Mapping in node ACL iqn.2014-12.com.example:desktop0

/>/iscsi/iqn.2014-12.com.example:server0/tpg1/portals Create 172.25.0.11

Using Default IP Port 3260

Created Network Portal 172.25.0.11:3260.

/> Exit

5. results after a successful configuration

650) this.width=650; "style=" width:568px;height:291px; "title=" Picture 2.png "src=" http://s3.51cto.com/wyfs02/M00/6E/62/ Wkiol1v62vaaxvmwaatfhfcmztk163.jpg "width=" 1008 "height=" 347 "alt=" wkiol1v62vaaxvmwaatfhfcmztk163.jpg "/>

Second, the client

1) yum install iscsi-initiator-utils.x86_64-y

2) iscsiadm-m discovery-t st-p 172.25.254.

3) Edit File Vim/etc/iscsi/initiatorname.iscsi

650) this.width=650; "style=" width:598px;height:75px; "title=" Picture 3.png "src=" http://s3.51cto.com/wyfs02/M00/6E/66/ Wkiom1v62dch_zuuaabyv7h252q413.jpg "width=" 456 "height=" + alt= "wkiom1v62dch_zuuaabyv7h252q413.jpg"/>

Systemctl Restart Iscsid.service

4 ) Find the iSCSI targets provided by the iSCSI Server ( target portal )

Iscsiadm-m discovery-t st-p 172.25.254.120

5) log on to one or more iSCSI targets on the server

Iscsiadm-m node-t iqn.2015-06.com.example:westos-p 172.25.254.120-l

-l: login    -m : operation     Span style= "font-family: ' Times New Roman ';" >-t: 

650) this.width=650; "style=" width:726px;height:188px; "title=" Picture 4.png "src=" http://s3.51cto.com/wyfs02/M02/6E/66/ Wkiom1v62fkdtuavaaggbcifn9w950.jpg "width=" "height=" 184 "alt=" Wkiom1v62fkdtuavaaggbcifn9w950.jpg "/>

6) Fdisk-l

FDISK/DEV/SDA re-partition /dev/vda1

Partprobe

Mkfs.xfs/dev/sda1

mount/dev/sda1/mnt/

   vim /etc/fstab  /etc/fstab

blkid Span style= "font-family: ' The song Body '; > OK file system uuid uuid mount , /dev/sd* device name. ( every time

The device names displayed at boot time are different , depending on the order in which the ISCSI devices respond over the network.

If you mount by device name , This causes the wrong device to be used. )

2. use _netdev as Mount option in /etc/fstab . ( This ensures that the client does not attempt to mount the file system

to enable networking. Otherwise , The system will fail at boot time. )

3. ensure that the iSCSI service starts at boot time.

Vim/etc/fstab

650) this.width=650; "title=" Picture 5.png "src=" http://s3.51cto.com/wyfs02/M00/6E/62/ Wkiol1v62hkcnggaaadiarrom9i323.jpg "width=" 686 "height=" " the alt=" wkiol1v62hkcnggaaadiarrom9i323.jpg "/>"

7) reboot Client, if not shut down properly, then poweroff can

Interrupt the use of ISCSI targets

Client:

1. Delete /etc/fstab first

2.mount/mnt

3.iscsiadm-m node-t iqn.2015-06.com.example:westos-p 172.25.254.100

Logging out of Session [Sid:1, Target:iqn.2015-06.westos.disk1:storage1,portal:172.25.254.132,3260]logout of [Sid:1, T  Arget:iqn.2015-06.westos.disk1:storage1, portal:172.25.254.132,3260] successful. ------- Temporary deletion succeeded

This will only temporarily delete /dev/sda-u: logoff

Systemctl Restart Iscsid.service

systemctl restart Iscsi.service

The/DEV/SDA partition will re-appearwhen the service iSCSI service is heavy:fdisk-l

4.iscsiadm-m node-t iqn.2015-06.com.example:westos-p 172.25.254.120-o Delete

Restart service completely remove /dev/vda

Service side:

1. Delete two files:

650) this.width=650; "style=" WIDTH:653PX;HEIGHT:137PX; "title=" Picture 6.png "src=" http://s3.51cto.com/wyfs02/M00/6E/66/ Wkiom1v62jtsb8gkaagdy5lhily783.jpg "width=" 649 "height=" 185 "alt=" wkiom1v62jtsb8gkaagdy5lhily783.jpg "/>

2.systemctl Restart Target If the service is not restarted, the operation will be re-saved

Can targetcli view:ls after the initial state

iSCSI Storage Modules

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.