With the increasing popularity of computers, the computer's protection God UPS has been widely used. UPS is the use of simple but its relatively fragile equipment, scientific use and maintenance will prolong the life of ups! Here are some of my experiences for your reference.
1, as far as possible not to connect the electrical inductive load. Because the inductive load of the starting current will often exceed the rated current 3~4 times, this will cause UPS instantaneous overload, affect UPS life. Inductive load including summer electric fans, refrigerators
Wait
2, not full load or excessive light load. Do not use it according to the UPS rated power, do not think that the empty interface should not idle and connect other electrical appliances, long-term full load state will directly affect the life of UPS. In general, the load amount of the online ups should be controlled in 70%~80%, while the load of the standby UPS should be controlled in 60%~70%. Note that too much light load is not good, although not as serious as overload.
3, the protection of good batteries. A very important component of UPS is the battery. At present, most small and medium ups use a sealed lead-acid battery without maintenance. Although on the surface it does not need maintenance, but poor care, the same will be wrong, not to mention the battery is very expensive. Data from the UPS Maintenance department indicate that about 30% of the UPS damage is actually just a battery failure. Therefore, the key to maintain the UPS is to maintain the battery. Comparatively speaking, the battery is more delicate, the request in 0~30℃ environment work, 25 ℃ the highest efficiency. Therefore, in winter and summer must pay attention to the UPS working environment. High temperature will shorten the battery life, the temperature is low, will not reach the nominal delay.
4, regular maintenance. In general, you should measure the battery's terminal voltage to the UPS in half a year. If the voltage exceeds 1V should use a balanced constant voltage limit (0.5A) charge, if it does not work, can only change new batteries. If the local long-term uninterrupted power outage, must be regular (three months) artificial interruption of power supply, so that ups with load discharge. Because the long time did not break the electricity, so you always think it is in the normal work, and in fact, once the power off, it can only provide a very short delay or even no delay, the reason is that the battery is in the floating charging state for a long time.
5, pay attention to prevent lightning. Lightning is the natural enemy of all electrical appliances, must pay attention to ensure the effective shielding ups and grounding protection. In addition, the UPS should be placed in a good ventilation and cooling places