iSCSI configuration for VMware VSphere vCenter 5.1

Source: Internet
Author: User
Tags failover

On the road (Lao Li) QQ group: 384423770

1. Select "Add Network"

2. Select the "VMkernel" connection type

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image001 "border=" 0 "alt=" clip_image001 "src=" http://s3.51cto.com/wyfs02/M00/58/40/ Wkiol1ss9jtr7f92aadbx6lt6ys696.jpg "" 557 "height=" 412 "/>

3. Select Create a vsphere standard switch and select two physical network adapters dedicated to iSCSI

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image002 "border=" 0 "alt=" clip_image002 "src=" http://s3.51cto.com/wyfs02/M01/58/40/ Wkiol1ss9jtz26ybaaglpcv_5rw677.jpg "" 565 "height=" 418 "/>

4. Set "Network label" to ISCSI01, if VLAN, enter VLAN ID, do not need to tick any other option

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image003 "border=" 0 "alt=" clip_image003 "src=" http://s3.51cto.com/wyfs02/M02/58/40/ Wkiol1ss9jwdkwzpaaexm7ltvyq670.jpg "" 583 "height=" 431 "/>

5. Enter the IP address information that must be stored on the same network segment as the iSCSI

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image004 "border=" 0 "alt=" clip_image004 "src=" http://s3.51cto.com/wyfs02/M00/58/40/ Wkiol1ss9jbqra6yaaezjk_eesu307.jpg "" 592 "height=" 438 "/>

6. The soon-to-be-completed

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image005 "border=" 0 "alt=" clip_image005 "src=" http://s3.51cto.com/wyfs02/M01/58/40/ Wkiol1ss9jbqpootaadokwfujzo287.jpg "" 590 "height=" 436 "/>

7. Complete the virtual network after adding iSCSI01, select the standard switch "VSWITCH2" and select "Properties"

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image006 "border=" 0 "alt=" clip_image006 "src=" http://s3.51cto.com/wyfs02/M02/58/40/ Wkiol1ss9jexz_jgaah-f3eczpc216.jpg "" 610 "height=" 446 "/>

8. Select "Add"

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image007 "border=" 0 "alt=" clip_image007 "src=" http://s3.51cto.com/wyfs02/M02/58/43/ Wkiom1ss9xjrvbeqaafizp18qqs233.jpg "" 617 "height=" 454 "/>

9. Select "VMkernel"

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image008 "border=" 0 "alt=" clip_image008 "src=" http://s3.51cto.com/wyfs02/M00/58/43/ Wkiom1ss9xidhae1aad8hvc8cgm688.jpg "" 623 "height=" 461 "/>

10. Set the network label to "ISCSI02", other settings such as "iSCSI01"

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image009 "border=" 0 "alt=" clip_image009 "src=" http://s3.51cto.com/wyfs02/M01/58/43/ Wkiom1ss9xndahm6aafpmvyoeyw330.jpg "" 628 "height=" 464 "/>

11. Set the IP address

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image010 "border=" 0 "alt=" clip_image010 "src=" http://s3.51cto.com/wyfs02/M02/58/43/ Wkiom1ss9xrytqt8aafnwy0vsh8768.jpg "" 632 "height=" 467 "/>

12. Nearing completion

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image011 "border=" 0 "alt=" clip_image011 "src=" http://s3.51cto.com/wyfs02/M00/58/43/ Wkiom1ss9xqxo3dcaaev5q2x6ee492.jpg "" 629 "height=" 465 "/>

13. Complete the addition of the iscsi02 Vmkernel, then select "ISCSI01" and select "Edit"

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image012 "border=" 0 "alt=" clip_image012 "src=" http://s3.51cto.com/wyfs02/M01/58/43/ Wkiom1ss9xuibbshaagntfhzlus278.jpg "" 630 "height=" 463 "/>

14. Select the "NIC Bindings" tab,

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image013 "border=" 0 "alt=" clip_image013 "src=" http://s3.51cto.com/wyfs02/M02/58/43/ Wkiom1ss9xysl0uvaafz2paigbi220.jpg "" 445 "height=" 550 "/>

15. Tick "Alternate switch failover Sequence" and select Network card VMNIC5, move the NIC to "unused adapter" by "Move Down", leave "vmnic2" on "Active adapter", then "OK save"

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image014 "border=" 0 "alt=" clip_image014 "src=" http://s3.51cto.com/wyfs02/M00/58/43/ Wkiom1ss9xzy-wjnaaghvsqxirm215.jpg "" 443 "height=" 547 "/>

16. Select "ISCSI02" and select "Edit"

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image015 "border=" 0 "alt=" clip_image015 "src=" http://s3.51cto.com/wyfs02/M01/58/43/ Wkiom1ss9x6zsljwaae1652av7o815.jpg "" 536 "height=" 394 "/>

17. Switch to the "network adapter Bindings" tab and tick "Alternate switch failover Sequence"

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image016 "border=" 0 "alt=" clip_image016 "src=" http://s3.51cto.com/wyfs02/M02/58/43/ Wkiom1ss9x_wavddaahm9cxqhki674.jpg "" 516 "height=" 638 "/>

18. Select the "vmnic2" physical network card, with the "name" of the network card in the "unused adapter", leaving "vmnic5" in the "Active adapter", and iscsi01 just the opposite.

That is, the iscsi01 Vmkernel is bound to the VMNIC2 physical network card, and Iscsi02 's vmkernel is bound to the VMNIC5 physical network card

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image017 "border=" 0 "alt=" clip_image017 "src=" http://s3.51cto.com/wyfs02/M00/58/43/ Wkiom1ss9ycg8yajaahfdusmlw8356.jpg "" 461 "height=" 569 "/>

19. Select "VSwitch" and select "Edit"

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image018 "border=" 0 "alt=" clip_image018 "src=" http://s3.51cto.com/wyfs02/M01/58/43/ Wkiom1ss9ygw0ayhaaela_oisp4435.jpg "" 538 "height=" 396 "/>

20. Switch to the "General" tab and set the "MTU" to 9000

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image019 "border=" 0 "alt=" clip_image019 "src=" http://s3.51cto.com/wyfs02/M02/58/43/ Wkiom1ss9ygc4dejaaeaai-_8gm775.jpg "" 514 "height=" 635 "/>

21. As with "vswitch", change the MTU of ISCSI01 to 9000

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image020 "border=" 0 "alt=" clip_image020 "src=" http://s3.51cto.com/wyfs02/M00/58/43/ Wkiom1ss9ykxenpeaaepbowfs9k181.jpg "" 487 "height=" 602 "/>

22. As with "vswitch", change the MTU of ISCSI02 to 9000

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image021 "border=" 0 "alt=" clip_image021 "src=" http://s3.51cto.com/wyfs02/M01/58/43/ Wkiom1ss9ypcyvx9aaeuxc9ghss122.jpg "" 468 "height=" 578 "/>

Note: The MTU setting requires an end-to-end setting, where both the Vmkernel and the virtual switch are set to the MTU of 9000, while the physical switch corresponds to the physical port and physical switch to be set to 9000 MTU, while the storage also needs to be set to support 9000 MTU, If one of the links is not set, the effect will decrease.

23. After two ESXi hosts have completed the virtual network setup, the virtual network settings of the ESXi host are all the same except for the IP, and the network sign and the physical NIC bindings are all the same

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image022 "border=" 0 "alt=" clip_image022 "src=" http://s3.51cto.com/wyfs02/M02/58/43/ Wkiom1ss9york4xxaaibtu9t-cs540.jpg "" 613 "height=" 473 "/>

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image023 "border=" 0 "alt=" clip_image023 "src=" http://s3.51cto.com/wyfs02/M00/58/40/ Wkiol1ss9kxrjgzaaajwwuuz4fs195.jpg "" 611 "height=" 548 "/>

24. Select the host, select "Configure", "Hardware" select "Storage Adapter" and select "Add" on the right.

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image024 "border=" 0 "alt=" clip_image024 "src=" http://s3.51cto.com/wyfs02/M00/58/43/ Wkiom1ss9yxg9p1haaif4vyr96c427.jpg "" 638 "height=" 472 "/>

25. Select "Address software ISCSI Adapter"

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image025 "border=" 0 "alt=" clip_image025 "src=" http://s3.51cto.com/wyfs02/M00/58/43/ Wkiom1ss9yartafdaacizpxyc1e176.jpg "" 389 "height=" 188 "/>

26. Select "OK"

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image026 "border=" 0 "alt=" clip_image026 "src=" http://s3.51cto.com/wyfs02/M02/58/40/ Wkiol1ss9kfwuuguaacfn-gp-d0736.jpg "" 436 "height=" 168 "/>

27. Select "Vmhba33" under "ISCSI software Adapter" and select "Properties"

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image027 "border=" 0 "alt=" clip_image027 "src=" http://s3.51cto.com/wyfs02/M00/58/40/ Wkiol1ss9kjzzb0eaanbhdjtnnw734.jpg "" 755 "height=" 558 "/>

28. Select "Configure" in the "General" selection card

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image028 "border=" 0 "alt=" clip_image028 "src=" http://s3.51cto.com/wyfs02/M00/58/44/ Wkiom1ss9yirusk3aadykcr9tp4746.jpg "" 461 "height=" 489 "/>

29. Set the iSCSI name and select OK

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image029 "border=" 0 "alt=" clip_image029 "src=" http://s3.51cto.com/wyfs02/M01/58/40/ Wkiol1ss9kmdki5kaadpipuyuzc671.jpg "" 429 "height=" 261 "/>

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image030 "border=" 0 "alt=" clip_image030 "src=" http://s3.51cto.com/wyfs02/M01/58/44/ Wkiom1ss9ymtob0oaaeg78psj08818.jpg "" 498 "height=" 529 "/>

30. Switch to "network Configuration" and select "Add"

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image031 "border=" 0 "alt=" clip_image031 "src=" http://s3.51cto.com/wyfs02/M02/58/40/ Wkiol1ss9kvj03kzaae8fusxlei510.jpg "" 553 "height=" 587 "/>

31. Select the "iSCSI01" Port Group and select "OK"

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image032 "border=" 0 "alt=" clip_image032 "src=" http://s3.51cto.com/wyfs02/M00/58/40/ Wkiol1ss9kyzq-pxaajrupqljsy062.jpg "" 513 "height=" 562 "/>

32. In the Vmkernel port binding, display the newly added ISCSI01 Port Group and display Group Policy as compliant, select Add, add iscsi02 port Group

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image033 "border=" 0 "alt=" clip_image033 "src=" http://s3.51cto.com/wyfs02/M01/58/40/ Wkiol1ss9k2dxjmtaahyewzdzya477.jpg "" 540 "height=" 573 "/>

33. Select "ISCSI02"

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image034 "border=" 0 "alt=" clip_image034 "src=" http://s3.51cto.com/wyfs02/M00/58/40/ Wkiol1ss9k6hobtyaakqej3lpcc737.jpg "" 567 "height=" 621 "/>

34. Complete the post-add effect of the iscsi01 and iscsi02 ports

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image035 "border=" 0 "alt=" clip_image035 "src=" http://s3.51cto.com/wyfs02/M02/58/44/ Wkiom1ss9y6r318caaju8ksooiq467.jpg "" 596 "height=" 633 "/>

35. Switch to "dynamic discovery" and select "Add"

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image036 "border=" 0 "alt=" clip_image036 "src=" http://s3.51cto.com/wyfs02/M01/58/40/ Wkiol1ss9k-zerfpaafiwe42bdm694.jpg "" 632 "height=" 671 "/>

Enter the IP address of the iSCSI storage in the iSCSI server, the port remains the default

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image037 "border=" 0 "alt=" clip_image037 "src=" http://s3.51cto.com/wyfs02/M00/58/44/ Wkiom1ss9y_zv-aaaadoll1evao344.jpg "" 426 "height=" 271 "/>

37. Complete the iSCSI Storage address additions and select "Off"

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image038 "border=" 0 "alt=" clip_image038 "src=" http://s3.51cto.com/wyfs02/M01/58/44/ Wkiom1ss9zdqpmzfaafmzfnw4mi691.jpg "" 576 "height=" 611 "/>

38. Select "Yes" to rescan the host's HBA card

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image039 "border=" 0 "alt=" clip_image039 "src=" http://s3.51cto.com/wyfs02/M02/58/44/ Wkiom1ss9zgyqzdjaaco0_1bqjg245.jpg "" 474 "height=" 188 "/>

39. Complete Multipath Network setup for iSCSI storage and add iSCSI storage, select Vmhba33, "Devices" below, display two storage LUNs

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image040 "border=" 0 "alt=" clip_image040 "src=" http://s3.51cto.com/wyfs02/M00/58/44/ Wkiom1ss9zks9jgvaam6era4kqc220.jpg "" 743 "height=" 598 "/>

40. Select "Memory" and select "Add Storage"

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image041 "border=" 0 "alt=" clip_image041 "src=" http://s3.51cto.com/wyfs02/M02/58/40/ Wkiol1ss9loxpcwwaakhqgjvrcs182.jpg "" 732 "height=" 589 "/>

41. Select "Disk/lun" memory type

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image042 "border=" 0 "alt=" clip_image042 "src=" http://s3.51cto.com/wyfs02/M01/58/40/ Wkiol1ss9lsx02zoaagzvkg9in0006.jpg "" 724 "height=" 565 "/>

42. Select a stored Lun

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image043 "border=" 0 "alt=" clip_image043 "src=" http://s3.51cto.com/wyfs02/M00/58/40/ Wkiol1ss9lwi3wxaaahy05pfer0706.jpg "" 787 "height=" 614 "/>

43. Select the file system version, this time select Vmfs-5

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image044 "border=" 0 "alt=" clip_image044 "src=" http://s3.51cto.com/wyfs02/M02/58/44/ Wkiom1ss9zwcoqpyaag5vp34kf0522.jpg "" 819 "height=" 639 "/>

44. Display the relevant partition information for the LUN you just selected

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image045 "border=" 0 "alt=" clip_image045 "src=" http://s3.51cto.com/wyfs02/M01/58/40/ Wkiol1ss9lbsljpaaaidgvlzlje644.jpg "" 827 "height=" 645 "/>

45. Enter the data store name

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image046 "border=" 0 "alt=" clip_image046 "src=" http://s3.51cto.com/wyfs02/M00/58/44/ Wkiom1ss9zfyf_8qaafzbsqky4o756.jpg "" 855 "height=" 667 "/>

46. Set the capacity size

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image047 "border=" 0 "alt=" clip_image047 "src=" http://s3.51cto.com/wyfs02/M02/58/40/ Wkiol1ss9libip2caagg8jmpnuc502.jpg "" 879 "height=" 686 "/>

47. Display related Information

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image048 "border=" 0 "alt=" clip_image048 "src=" http://s3.51cto.com/wyfs02/M01/58/44/ Wkiom1ss9zjcfodwaai8zsetbdq114.jpg "" 877 "height=" 684 "/>

48. Complete the addition of disk storage and format the file system

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image049 "border=" 0 "alt=" clip_image049 "src=" http://s3.51cto.com/wyfs02/M02/58/44/ Wkiom1ss9znjinidaaoh6nd0hi0157.jpg "" 865 "height=" 696 "/>

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image050 "border=" 0 "alt=" clip_image050 "src=" http://s3.51cto.com/wyfs02/M01/58/40/ Wkiol1ss9luhpqdgaarszsqbjbe282.jpg "" 871 "height=" 701 "/>

iSCSI configuration for VMware VSphere vCenter 5.1

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.