Http://www.cardwerk.com/smartcards/smartcard_standard_ISO7816-4_7_transmission_interindustry_commands.aspx
7. transmission-oriented interindustry Commands
7.1 GET RESPONSE Command
7.2 ENVELOPE Command
It shall not being mandatory for all cards complying to this part of ISO/IEC 7816 to support all the described commands or AL L The options of a supported command.
When international interchange was required, a set of card system services and related commands and options shall be used a s defined in clause 9.
Table One provides a summary of the commands defined in this part of ISO/IEC 7816.
The impact of secure messaging (see 5.6) on the message structure was not described in this clause.
The list of error and warning conditions given in each clause 7.x.5 are not exhaustive (see 5.4.5).
7.1 GET RESPONSE command
7.1.1 Definition and scope
7.1.2 Conditional usage and security
7.1.3 Command Message
7.1.4 reponse Message (nominal case)
7.1.5 Status Conditions
7.1.1 Definition and scope
The GET RESPONSE command is used to transmit from the card to the interface device APDU (s) (or part of the APDUs) which OT Herwise could not being transmitted by the available protocols.
7.1.2 Conditional usage and security
No condition.
7.1.3 Command Message
Table 74-get RESPONSE command APDU
Cla |
As defined in 5.4.1 |
Ins |
' C0 ' |
P1-p2 |
' 0000 ' (other values is RFU) |
Lc Field |
Empty |
Data Field |
Empty |
Le Field |
Maximum length of data expected in response |
7.1.4 Response Message (nominal case)
Table 75-get RESPONSE RESPONSE APDU
Data Field |
(part of) APDU according to Le |
Sw1-sw2 |
Status bytes |
7.1.5 Status conditions
The following specific normal processing may occur:
sw1= ' + ' with SW2
- ' xx ': Normal processing:more data bytes is available (' xx ' indicates a number of extra data bytes still available by sub Sequent GET RESPONSE).
The following specific warning condition may occur:sw1= ' + ' with sw2=
- ' Bayi ': Part of returned data corrupted
The following specific error conditions may occur.
sw1= ' sw2= ' with
- ' xx ': Wrong Length (the Lc field is incorrect)
sw1= ' 6A ' with sw2=
- ' Incorrect ': Parameters p1-p2
sw1= ' 6C ' with sw2=
- ' xx ': Wrong Length (wrong Le field, ' xx ' indicates the exact length)
7.2 ENVELOPE Command
7.2.1 Definition and scope
7.2.2 Conditional usage and security
7.2.3 Command Message
7.2.4 reponse Message (nominal case)
7.2.5 Status Conditions
7.2.1 Definition and scope
The ENVELOPE command is used to transmit APDU (s) or part of APDUs or any data string which otherwise could not being transmit Ted by the available protocols.
NOTE -the usage of ENVELOPE for SM was shown in annex F.
7.2.2 Conditional usage and security
No condition.
7.2.3 Command Message
Table 76-envelope Command APDU
Cla |
As defined in 5.4.1 |
Ins |
' C2 ' |
P1-p2 |
' 0000 ' (other values is RFU) |
Lc Field |
Length of the subsequent data field |
Data Field |
(part of) APDU |
Le Field |
Empty of length of expected data |
When the ENVELOPE command was used under t=0 for transmitting data strings, a empty data field in an ENVELOPE command APDU means end of data string.
7.1.4 Response Message (nominal case)
Table 77-envelope Response APDU
Data Field |
Empty or (part of) APDU according to Le |
Sw1-sw2 |
Status bytes |
NOTE -the status bytes belong to the ENVELOPE command. Status bytes of a command transmitted in the data field of the ENVELOPE command is found in the data field of the Enve LOPE Response.
7.2.5 Status conditions
The following specific error conditions may occur.
sw1= ' sw2= ' with
- ' xx ': Wrong Length (the Lc field is incorrect)
ISO 7816-4: GET RESPONSE and ENVELOPE command