Local cabling solution for small and medium Networks

Source: Internet
Author: User
Tags server cabinet

Local cabling solution for small and medium Networks

What will happen to your computer room if you like things to be littered?

Experience in IDC network cabling:

Overall:

1. Try to find the same company as possible for IDC room decoration and cabling. Otherwise, it is difficult to coordinate and unify many aspects, such as cleaning and sanitation of the IDC room and design and decoration of the IDC room. One-stop service is conducive to cabling.

2. if you want to find a company with real experience in IDC room decoration, you can go to the actual project site to learn about their technical level and strength, there are too many companies on the market that claim that they have decorated their IDCs.

3. before decorating the IDC, it is best to ask the consultant to come to the site and ask them to propose a solution. First, they should look at the design of the IDC as a reference by their designers, and then modify it according to our internal needs, set a solution.

4. Separate Weak Current and strong current.

5. It is recommended that the data center follow-up personnel should arrange two persons to work together and take turns Based on overtime. In case of problems, they can also coordinate based on the situation.

6. When you order the device model, it is best to see the sample first to avoid any deviation.

7. There is no idea how to effectively clean up and clean the house in the early stage.

Design details:

1. It is best to buy a dedicated network cabinet for network wiring cabinets. The design of the network cabinet mainly includes two solutions: a. In a network cabinet, a distribution frame is equipped with a switch, and one pair is erected on one pair. B. the distribution frame has an independent network cabinet, and the switch has an independent network cabinet. The above two solutions facilitate cabling.

2. The quality of the anti-static floor of the data center should be good, with a strong bearing capacity and a minimum capacity of 700.

3. The ceiling is dust-proof, the gas is fire-resistant, the walls are wet, the paint quality is good, the floor is load-bearing, the steel frame is used, the ground is anti-static, and lightning protection is well done. The Building Lightning Protection is different from the machine lightning protection of the data center (different requirements ).

4. There are two ways to wire the network cable: a. take the floor, so the height of the cable trough is sufficient. The minimum height is 30 ~ 40 cm to prepare for cabling. B. Take the rack over the rack and complete the cable rack.

The two methods determine the distribution frame location, air conditioner location, dust-proof mode, and heat dissipation mode. We recommend that you use air conditioners to avoid dripping air conditioners.

5. several network cable cabling methods. Considering the possibility and feasibility of future maintenance, we do not recommend separating the network by service network. We recommend separating the network by Cabinet, adding a network cable to one cabinet, and sorting the cables by number, network cabinets are allocated on distribution racks in a numerical order. That is, a large bundle of cabinets. A bundle of cables.

6. network cable trough/rack design, the trough must be wide and tall enough, the turning position cannot be at a right angle, the corner must be turned, the network cable location should be avoided as much as possible, but cross is inevitable, when designing a cable slot, consider the location of the line. The design of the cable slot of the server Cabinet must be different from that of the network cabinet, because the layout should be summarized.

7. three plug-in sockets and waterproof sockets under the Cabinet should be set in front of the server Cabinet (less lines can be in this grid, not recommended), network cabinets must be in front of one grid. The bearing capacity must be taken into account at the opening position under the Cabinet. The opening position is in the front of the bearing Board to facilitate cabling.

8. You need to set up a third-way socket in all directions.

9. When there are multiple network cabinets, a dedicated distribution frame must be set up for interconnection between network cabinets, which can provide necessary support for future network setup and maintenance.

10. The distribution frame device of the network cabinet is different from that of the distribution frame device of the server cabinet. The distribution frame of the network cabinet is in front, and the distribution frame of the server cabinet is in front. Based on this, the length of the network cable is different.

11. The walls of the IDC room should be well protected against moisture and dust, otherwise they will be yellow.

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.