Measurement results table in line with the closed full circle method wire record table

Source: Internet
Author: User

Still struggling to find a suitable wire record table, Old Wang shared his frequently used record table, let you one step in place, not to worry about the measurement results table that conforms to the closed full circle method wire record table calculation table, I put the corresponding images and brief descriptions in my measurement space. For your use.

1. Wire record table 1 (applicable to conforming wire, closed wire, and wire)

A concise record table is used for multi-test back, angle measurement, which can reflect the 2C value and the final left (right) angle. The following operations can also be performed to observe the triangular elevation. This is very practical. It was left by the old master and I have been using it.

Wire record table 1 ······
2. Wire record table 2 (applicable to conforming wires, closed wires, and branch wires)

This table is relatively regular and is not as easy to understand as the first table, but it is a standard! The following are observations, calculations, conformity and supervision, and a total of signature opinions. This table is suitable if you prefer the format.

Wire record table 2 ······
3. Wire record table 3 (applicable to full circle angle measurement)

 

The general full circle method observation angle record table, Excel also has the computing function, maybe you have a pad, the field record can also be automatically calculated Oh!

Wire record table 3 (applicable to Angle Measurement by full circle method )······
Iv. Wire calculation table (applicable to coordinate derivation of connecting wires)

This table has a disadvantage. Because word does not have a formula, it cannot be used to input known data and directly calculate it. However, it is a standardized table format. If you want to tabulation, you can refer to this

Wire calculation table (applicable to coordinate derivation of connecting and connecting wires)
5. Wire result table (applicable to re-test wire coordinate result report)

Which of the preceding tables is a set of complete data, which can reflect the actual design coordinates, the difference between their XY values, and the distance deviation, the signatures of various persons in charge are as follows.

Wire result table (applicable to the re-test wire coordinate result report )······

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.